| Literature DB >> 26350934 |
Hans R Preus1, Gerald Ruiner Torgersen2, Odd Carsten Koldsland3, Bjørn Frode Hansen4, Anne Merete Aass5, Tore Arne Larheim6, Leiv Sandvik7.
Abstract
BACKGROUND: The reproducibility of measurements on radiographs is influenced by the techniques by which the images as well as the measurements are obtained. Thus, bias resulting from errors in the image and/or image examinations at two points in time may result in wrongful registrations of true biological or pathological changes. The aim of the present study was to propose and evaluate an indirect radiological examination technique, by which bias, when measuring radiographic bone level, could be substantially reduced as compared to the technique using direct mm measurements.Entities:
Mesh:
Year: 2015 PMID: 26350934 PMCID: PMC4562112 DOI: 10.1186/s12903-015-0092-9
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
The physical length in mm of the 20 teeth with artificially elevated bone level as compared to the length obtained by reading the lengths on the radiographs
| Scull No. | Root designation | Root length in mma. | Root length in mm measured on X-raysb |
|---|---|---|---|
| 1 | 36Mc | 21.34 | 21.5. |
| 1 | 36Dc | 20.35 | 21.4. |
| 1 | 35 | 20.71 | 21.6. |
| 1 | 34 | 20.28 | 21,7. |
| 1 | 32 | 23.36 | 23,4. |
| 1 | 43 | 24.13 | 25.4. |
| 1 | 44 | 21.20 | 21.3. |
| 1 | 45 | 21.19 | 22.7. |
| 5 | 37M | 20.14 | 20.4. |
| 5 | 37D | 19.13 | 19.5. |
| 5 | 35 | 21.20 | 20.8. |
| 5 | 47M | 20.23 | 22.6. |
| 5 | 47D | 19.52 | 20.7. |
| 6 | 43 | 18.26 | 18.1. |
| 6 | 44 | 18.90 | 19.5. |
| 7 | 37M | 18.39 | 19.9. |
| 7 | 37D | 18.17 | 19.0. |
| 7 | 35 | 20.10 | 20.4. |
| 7 | 32 | 23.19 | 23.2. |
| 7 | 42 | 23.75 | 24.3. |
| 7 | 45 | 22.14 | 22.4. |
| 8 | 47M | 19.06 | 19.8. |
| 8 | 47D | 18.34 | 18.9. |
| 9 | 36M | 21.19 | 21.4. |
| 9 | 36D | 20.26 | 21.0. |
| 10 | 33M | 18.98 | 19.7. |
aTooth Length measured by Digital caliper (Cocraft, United Kingdom)
bAverage Tooth length measured on radiographs by examiner 1 (HRP)
c M mesial root; D distal root
Fig. 1Schematic setup of the angles of projection
Fig. 2Schematic setup of imaging geometry
Fig. 3a. Experimental setup showing elevated teeth in their sockets and Eggens holder with sensor at α = 0°. b. The Eggens holders with regular α = 0° and modified to α = 30°
Fig. 4Radiograph with markings and application (plugin) running
Fig. 5Schematic drawing of the measuring points of the imaged object (tooth). Points are marked on both mesial (M) and distal (D) aspect of image
Length of tooth = INC/OCL - APEX, RBL (Roentgenological Bone Level = AC-CEJ) and rel RBL (%RBL/L) in X-rays obtained at 0 and 30 ° angle with artificially increased AL (actual bone level ~ 7 mm)
|
| 0 | 30 ° |
| |
|---|---|---|---|---|
| INC/OCL – Apex (mm) | mean | 22.1 | 24.7 | <0.001 |
| SD | 2.3 | 2.2 | ||
| RBL (mm) | mean | 7.0 | 7.8 | 0.032 |
| SD | 1.1 | 1.6 | ||
|
| Mean | 31.4 | 31.6 | 0.903 |
| SD | 3.8 | 5.3 | ||
| N |
|
|