Literature DB >> 26309515

A novel guide device improves the accuracy of pedicle screw placement.

Lei Yang1, Haijun Li1, Jian Tang1, Dawei Ge1, Xiaojian Cao1.   

Abstract

Pedicle screw placement in thoracic and lumbar spine is technically demanding and involves radiation exposure. Commercially available systems for pedicle screw insertion are expensive and cannot be widely used for those less-developed areas. The purpose of our study was to develop a simple guide device assisting pedicle screw placement and improving the accuracy in the operation. A simple guide device was developed with the aim of improving accuracy of pedicle screw technique based on anatomical structures of the spine. We retrospectively collected clinical data of 111 consecutive patients who received treatment of pedicle screw internal fixation between January 2013 and September 2014. In total, 518 screws were inserted by the same surgeon, among which 280 screws were implanted in 60 patients (33 males and 27 females) with conventional freehand technique and 238 screws were implanted in 51 patients (27 males and 24 females) using the guide device. According to postoperative CT evaluation, screws were classified into different grades and accuracy rates were compared between the two groups. A total of 518 screws were placed (238 in the guide group, 280 in the conventional group). No intra-operative or postoperative complications such as infection, vessel and nerve injuries occurred. After postoperative CT evaluation, 215 from guide group and 236 from the conventional group were classified in Grade 1. Only screws in Grade 1 were considered as accurate insertion. Thus, the accuracy rates were 84.3% for the conventional group and 90.3% for the guide group respectively. Through statistical test, there was significant difference in the accuracy rate between two groups. The simple guide device significantly improves the accuracy of pedicle screw placement. Combined with the advantage of cheapness, it can be widely used in spinal internal fixations, especially suitable for those inexperienced spine surgeons in less-developed areas.

Entities:  

Keywords:  Pedicle screw; accuracy rate; guide device; radiation exposure; thoracolumbar spine

Year:  2015        PMID: 26309515      PMCID: PMC4538093     

Source DB:  PubMed          Journal:  Int J Clin Exp Med        ISSN: 1940-5901


  18 in total

1.  Complications and problems related to pedicle screw fixation of the spine.

Authors:  Pavlos Katonis; Joseph Christoforakis; George Kontakis; Agisilaos C Aligizakis; Charalampos Papadopoulos; George Sapkas; Alexander Hadjipavlou; George Katonis
Journal:  Clin Orthop Relat Res       Date:  2003-06       Impact factor: 4.176

2.  Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques.

Authors:  Yasser Allam; J Silbermann; F Riese; R Greiner-Perth
Journal:  Eur Spine J       Date:  2012-09-25       Impact factor: 3.134

3.  Placement of thoracic transvertebral pedicle screws using 3D image guidance.

Authors:  Eric W Nottmeier; Stephen M Pirris
Journal:  J Neurosurg Spine       Date:  2013-03-08

4.  Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine.

Authors:  L P Amiot; K Lang; M Putzier; H Zippel; H Labelle
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

5.  Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine.

Authors:  D P Jones; P A Robertson; B Lunt; S A Jackson
Journal:  Spine (Phila Pa 1976)       Date:  2000-06-15       Impact factor: 3.468

6.  Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Orthop Clin North Am       Date:  1986-01       Impact factor: 2.472

Review 7.  Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws.

Authors:  Oliver P Gautschi; Bawarjan Schatlo; Karl Schaller; Enrico Tessitore
Journal:  Neurosurg Focus       Date:  2011-10       Impact factor: 4.047

8.  The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion.

Authors:  Ji Young Cho; Chee Keong Chan; Sang-Ho Lee; Ho-Yeon Lee
Journal:  Comput Aided Surg       Date:  2012

9.  Internal fixation of the lumbar spine with pedicle screw plating.

Authors:  R Roy-Camille; G Saillant; C Mazel
Journal:  Clin Orthop Relat Res       Date:  1986-02       Impact factor: 4.176

10.  Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques.

Authors:  Jimmy Villard; Yu-Mi Ryang; Andreas K Demetriades; Andreas Reinke; Michael Behr; Alexander Preuss; Bernhard Meyer; Florian Ringel
Journal:  Spine (Phila Pa 1976)       Date:  2014-06-01       Impact factor: 3.468

View more
  4 in total

1.  A novel screw view model of 3D navigation for upper cervical pedicle screw placement: A case report.

Authors:  Jianwu Zhao; Lili Yang; Shuang Zheng; Yang Qu; Xiwen Zhang; Mingyang Kang; Rongpeng Dong; Xin Zhao; Tong Yu
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

2.  Screw view model of navigation in posterior corrective surgery for adolescent idiopathic scoliosis: A case report and technique note.

Authors:  Tong Yu; Lili Yang; Shuang Zheng; Yang Qu; Xiwen Zhang; Mingyang Kang; Rongpeng Dong; Jianwu Zhao
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

3.  Combined 3D rapid prototyping and computer navigation facilitate surgical treatment of congenital scoliosis: A case report and description of technique.

Authors:  Qiu-Ju Li; Tong Yu; Lian-Hua Liu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

4.  Combined 3-dimensional printing model and 3-dimensional fluoroscopic navigation to assist C2 pedicle screw insertion: A case report.

Authors:  Hao-Tian Xu; Shuang Zheng; Rong-Peng Dong; Tong Yu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.