The biomaterials challenge: A comparison of polyethylene wear using a hip joint simulator.

Saverio Affatato1, Nadia Freccero2, Paola Taddei3.   

Abstract

Although hip arthroplasty is an established procedure that relieves pain and improves functions, problems remain with wear and osteolysis. Highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years to solve these problems. In this study we compared the in vitro wear behaviour of cross-linked polyethylene (XLPE) versus Vitamin-E diffused XLPE (XLPE_VE) versus conventional ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. The test was performed using a hip joint simulator run for two millions cycles under bovine calf serum as lubricant. Mass loss was found to decrease along the series UHMWPE>XLPE_VE>XLPE, although statistically significant differences were found only between the mass losses of XLPE and UHMWPE at 1.2 and 2 million cycles. The mass loss data were explained in relation to the crystalline morphology of the control unworn cups, as investigated by non-destructive micro-Raman spectroscopy. This technique allowed to disclose a different wear behaviour of the three sets of cups. Wear testing produced a stress-induced crystallisation in UHMWPE, with increases in both amorphous (αa) and orthorhombic (αo) phases at the expense of the third phase (αb), which decreased upon wear. Moreover, the all-trans content decreased, while the ortho-trans content increased, contrarily to the trend observed for XLPE and XLPE_VE, for which no statistically significant changes in αo, αa and αb contents were detected. The XLPE_VE specimens underwent the least significant changes in the spectroscopic markers of micromorphology upon mechanical stress, probably due to their lower starting amorphous content.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cross-linked polyethylene; Hip simulator; Raman spectroscopy; Ultra-high molecular weight polyethylene; Vitamin-E doped polyethylene

Mesh:

Substances:

Year:  2015        PMID: 26301318     DOI: 10.1016/j.jmbbm.2015.08.001

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  8 in total

1.  Micro X-Ray Computed Tomography Mass Loss Assessment of Different UHMWPE: A Hip Joint Simulator Study on Standard vs. Cross-Linked Polyethylene.

Authors:  Saverio Affatato; Filippo Zanini; Simone Carmignato
Journal:  PLoS One       Date:  2017-01-20       Impact factor: 3.240

2.  Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography.

Authors:  Saverio Affatato; Filippo Zanini; Simone Carmignato
Journal:  Materials (Basel)       Date:  2017-03-03       Impact factor: 3.623

3.  Wear Simulation of Ceramic-on-Crosslinked Polyethylene Hip Prostheses: A New Non-Oxide Silicon Nitride versus the Gold Standard Composite Oxide Ceramic Femoral Heads.

Authors:  Makiko Yorifuji; Saverio Affatato; Toshiyuki Tateiwa; Yasuhito Takahashi; Takaaki Shishido; Elia Marin; Matteo Zanocco; Wenliang Zhu; Giuseppe Pezzotti; Kengo Yamamoto
Journal:  Materials (Basel)       Date:  2020-06-29       Impact factor: 3.623

4.  Crystalline Characteristics and Their Influence in the Mechanical Performance in Poly(ε-Caprolactone) / High Density Polyethylene Blends.

Authors:  Enrique Blázquez-Blázquez; Ernesto Pérez; Vicente Lorenzo; María L Cerrada
Journal:  Polymers (Basel)       Date:  2019-11-13       Impact factor: 4.329

Review 5.  Biomimetic materials based on zwitterionic polymers toward human-friendly medical devices.

Authors:  Kazuhiko Ishihara
Journal:  Sci Technol Adv Mater       Date:  2022-09-13       Impact factor: 7.821

6.  Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator.

Authors:  Saverio Affatato; Alessandro Ruggiero; Sami Abdel Jaber; Massimiliano Merola; Pierangiola Bracco
Journal:  Materials (Basel)       Date:  2018-03-16       Impact factor: 3.623

7.  Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking.

Authors:  Alessandro Ruggiero; Massimiliano Merola; Saverio Affatato
Journal:  Materials (Basel)       Date:  2018-04-09       Impact factor: 3.623

8.  Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants.

Authors:  Saverio Affatato; Massimiliano Merola; Alessandro Ruggiero
Journal:  Materials (Basel)       Date:  2018-07-25       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.