Literature DB >> 26300955

Surgical results with the use of Silicated Calcium Phosphate (SiCaP) as bone graft substitute in Posterior Spinal Fusion (PSF) for Adolescent Idiopathic Scoliosis (AIS).

Nanjundappa S Harshavardhana1, Mohammed H H Noordeen2.   

Abstract

BACKGROUND: The gold standard iliac crest bone graft (ICBG) used to achieve arthrodesis in spinal fusions is not without complications (donor-site morbidity, iliac wing fractures etc.…). Our objectives were to evaluate the role of silicated calcium phosphate (SiCaP), an osteoconductive synthetic bone graft substitute in conjunction with locally harvested autologous bone in achieving arthrodesis following posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS) and report clinic-radiological results / adverse events with its use in a prospective single surgeon case series (Level of evidence [LoE] IV) treated by low implant density index (IDI) constructs (i.e., IDI ≤1.5).
METHODS: Thirty-five patients (8♂ & 2727♀) who underwent PSF and followed-up for a minimum of 2 years formed the study cohort. The mean age at surgery was 15 years (range: 11-21y) and pre-op Cobb angle was 60° (range: 40°-90°). SiCaP mixed with locally harvested bone during exposure and instrumentation was laid over instrumented segments. The average SiCaP used per patient was 32mls (range: 10-60mls). Radiographs were assessed for fusion at serial six monthly follow-ups. All clinical adverse events and complications were recorded.
RESULTS: The mean follow-up was 2.94 years (range: 2-4y). The post-op Cobb angle improved to 23° (range: 2°- 55°) and the mean in-patient stay was 7.72 days (range: 5-13d). The mean number of instrumented segments was 9.4 (range: 4-13) and implant density index (IDI) averaged 1.23 (range: 1.15-1.5). Radiographic new bone formation was seen within 3 months in all cases. All patients (except two) were highly satisfied at minimum follow-up of 8 years. There were two complications warranting revision surgery (deep infection, and implant failure without any evidence of pseudarthrosis). There were no SiCaP specific adverse events in any of the 35 patients.
CONCLUSION: SiCaP facilitated early bony consolidation in operated cohort of AIS patients treated by PSF. There were no inflammatory reaction or other adverse effects associated with its use. SiCaP is a safe alternative to autologous iliac crest bone graft with reduced complications, morbidity, faster recovery and similar infection/fusion rates reported in the literature.

Entities:  

Keywords:  Bone Graft substitutes; Idiopathic Scoliosis (IS); Posterior Spinal Fusion (PSF); Silicated Calcium Phosphate (SiCaP)

Year:  2015        PMID: 26300955      PMCID: PMC4545986          DOI: 10.1186/s13013-015-0051-x

Source DB:  PubMed          Journal:  Scoliosis        ISSN: 1748-7161


Background

Adolescent Idiopathic scoliosis (AIS) is characterized by a frontal plane deformity of the spine and its exact etiology is unknown. Numerous theories are proposed to explain its etiology and pathogenesis [1]. Cobb angle is used to quantify and assess progression of deformity on standard PA radiographs, which have a three-fold reduced radiation to breast tissue than AP x-rays [2, 3]. Surgery is recommended and performed when the Cobb angle is ≥50°. Surgery addresses the shoulder, flank asymmetry and arrests progression of deformity. It also enhances self-esteem, improving body self-image, overall appearance and quality of life [4]. The first reported use of instrumentation for scoliosis was by Harrington [5]. Emphasis on achieving sound arthrodesis is attributed to JH Moe who recommended facetal and inter-laminar fusion [6]. Autologous iliac crest bone graft (ICBG) is considered to be gold standard in achieving arthrodesis for idiopathic scoliosis [7]. Numerous studies have reported excessive blood loss, iliac wing fractures, limited bone stock, prolonged hospital stay, increased pain and donor site morbidity with harvest and use of ICBG [8, 9]. Allografts and other synthetic bone graft substitutes are commonly used to minimise the risks associated with use of ICBG. The biological properties of allografts are variable and greatly influenced by processing techniques employed. Price reported 28 % pseudarthrosis rates with use of allografts for spinal fusions in comparison to 12 % for ICBG [10]. Silicated calcium phosphate (SiCaP) is a synthetic and porous bone graft substitute (ACTIFUSE™; ApaTech and Baxter Ltd, Elstree, Hertfordshire; UK) that is manufactured against highly controlled specifications mimicking the trabecular architecture of native cancellous bone as granules. It is available for use in two sizes with granule diameters of 1–2 and 2–5 mm. The silicate substitute at 0.8 % concentration by its negative surface charge significantly improves bone formation by increasing vascularity to host bone [11]. Studies have also demonstrated accelerated bone formation, enhanced volume of new bone formed and consolidation with remodelling into mature bone in-vivo animal studies [12]. SicaP’s use is well-documented and reported for degenerative spinal disorders. No published literature exists till date reporting its use in isolation (i.e., without mixing with vertebral or bone marrow aspirate or ICBG) in scoliosis surgeries and long spinal fusions. The purpose of this prospective clinical study was to evaluate the clinical and radiographic outcomes with its isolated as a bone graft substitute in conjunction with locally harvested bone in AIS patients treated by posterior spinal fusion (PSF) with low implant density index (IDI) constructs.

Methods

Thirty five consecutive patients with AIS scheduled for posterior spinal fusion at our institution were enrolled into this prospective study against pre-determined stringent inclusion criteria following a research and ethics committee (REC) approval which were: Age at surgery – at least 11 years Cobb angle of structural thoracic curve ≥50° and that of thoraco-lumbar/lumbar curve ≥40°. Patients/parents & care givers signed a written consent form voluntarily agreeing to participate in the study. The exclusion criteria included: AIS treated by anterior or combined anterior + posterior surgery Revision spinal surgeries and scoliosis secondary to other etiologies (i.e., congenital/neuromuscular/syndromic etc.…) Patients with known malignancy or local/systemic infection Those who refused to provide consent to participate in the study. Information brochure about ACTIFUSE™ was provided to enrolled patients and all questions were convincingly answered by the surgical team before their surgeries. The senior author (MHHN) has devised a surgical algorithm that identifies all AIS curves as three main curve types (I-III). Each curve type is further sub-divided into sub-type A & B depending on whether the convex shoulder was higher or lower to inter-clavicular line thus yielding six curve patterns that all AIS curves fitted into. The definition of these three curve types with illustrative line diagram is illustrated in Fig 1.
Fig. 1

The Noordeen AIS curve algorithm: Six curve patterns

The Noordeen AIS curve algorithm: Six curve patterns

Surgical procedure

All patients underwent scoliosis correction by third generation instrumentation through a midline posterior approach by means of a segmental all pedicle screws or hybrid construct plus cobalt-chrome rod system. Three instrumentation systems used were:- Expedium Spine System (De-Puy Spine Inc., Raynham, Massachusetts, USA) Synergy Spine Instrumentation (Interpore Cross International, Irvine, California, USA). K2M Spine Solutions (K2M Inc., Leesburg, Virginia, USA) After appropriate exposure of the spine by meticulous subperiosteaal dissection and haemostasis, facetectomies were performed. Cell saver and transfusion recycler was used in all cases and intra-operative estimated blood loss (EBL) was recorded as percentage of estimated blood volume (EBV). Pedicle screws were instrumented in the selected vertebrae after confirming the upper and lower instrumented vertebrae (i.e., UIV and LIV) with intra-operative fluoroscopy. Alternating convex and concave pedicle screws were inserted into the vertebrae (i.e., each vertebra had only one pedicle screw) except the end vertebrae, which had bilateral pedicle screws in all 35 patients. The implant density index (IDI) was no more than 1.5 in all cases. A pre-bent and appropriately contoured rod in sagittal plane was then inserted and correction was accomplished by a combination of the cantilever and translation manoeuvres. The convex (right sided rod) was inserted first to aid in translation and application of cantilever forces for correction. Finally, direct vertebral rotation was performed to correct the axial deformity. At the end of surgical correction, the spinous processes were resected and outer cortices of laminae were decorticated. 20–60mls of ACTIFUSE™ (depending on the no. of vertebral segments to be fused and quantity of locally harvested bone) was mixed at 60:40 ratio (i.e., 60 % of SiCaP and 40 % of autograft). The resulting composite material was laid over the prepared bony bed across the entire instrumented segment of the spine prior to the closure to facilitate arthrodesis.

Postoperative care and rehabilitation

Swimming, Pilates and gentle stretching was encouraged at 6 weeks onwards. Cycling and non-contact sports permitted at 6 months postoperatively. Contact sports and horse riding was prohibited for up to a year. None of the patient wore any orthosis in the postoperative period.

Radiographic & statistical analysis

All patients had preoperative standardized long-cassette erect PA and lateral radiographs. Supine side- bending views were performed to assess flexibility of structural and compensatory curves to aid decision-making in performing a selective spinal fusion. The senior author has devised a surgical algorithm and classified AIS into three curve main types. This simplified surgical algorithm also aided us in choosing fusion levels and was strictly adhered to for all cases. The curve characteristics of all patients as per the senior author’s algorithm is summarised in Table 1. Serial post-op radiographs were performed at the time of discharge, 3, 6, 12 and 24 months post-op follow-up. The radiographs were evaluated for instrumentation failure, lucency around the screws, anchor pull-out or dislodgement from its initially inserted position and for defects in the fusion mass as indicators of pseudarthrosis by a fellowship trained junior colleague with input from an independent Consultant radiologist who was not involved in the patients’ treatment. Cobb angles of structural and compensatory curves were measured pre and serial postoperative radiographs using the same vertebral segments as preoperative x-rays. The degree of postoperative curve correction and loss of correction with time at final follow-up was diligently recorded. Pseudarthrosis when present was recorded as definite or probable. A definite non-union existed when proven by a CT scan (on 1–2 mm fine-cut osteo window) and presence of frank defect during revision surgery Pseudoarthrosis was considered as probable when:
Table 1

Results - Summary of perioperative parameters in all 35 patients

Patient IDSexAge at SxF/u in moLevels fusedInstrumented SegmentsIDIActifuse wt. in mlsTotal Blood loss (EBV)Intra-op BTa Post-op BTa Pre-op VASVAS at DischargeFinal f/u VASComplicationFusionInstrumentation system
1001F2148T2-L1111.18400.200211NoneGoodSynergy
1002F1930T3-L3121.16200.300210NoneGoodSynergy
1003M1930T2-L2121.16400.400100NoneGoodK2M
1004F1430T3-L1101.2200.2500100NoneGoodK2M
1005F1448T4-L2101.2200.3500000NoneGoodSynergy adult
1006F1648T3-L1101.2400.300000NoneGoodK2M
1007M1448T3-L3121.16400.4500020MRSA deep infectionGoodSynergy
1008F1424T3-L3121.16400.3500000NoneGoodSynergy
1009F1248T3-T1181.25400.2500210NoneGoodSynergy
1010F1448T3-T1181.25300.300200NoneGoodSynergy
1011F1336T4-T1061.33200.200200NoneGoodSynergy
1012F1330T2-T12101.2250.2500320NoneGoodK2M
1013M1548T3-L3121.16400.300000NoneGoodK2M
1014F1130T2-T12101.2400.300000NoneGoodK2M
1015F1324T3-L1101.2400.300000NoneGoodK2M
1016F1330T2-L1111.18300.300621NoneGoodSynergy adult
1017M1530T3-T1181.25300.2500210NoneGoodK2M
1018F1448T4-T1281.25300.2500311NoneGoodSynergy
1019F1948T2-L3131.15400.3500000Right rod at T9 is brokenGoodK2M
1020F1548T2-L2121.16600.3500000NoneGoodK2M
1021F1824T4-L2101.2350.2800000NoneGoodSynergy adult
1022F1224T4-L2101.2400.300310NoneGoodK2M
1023M1624T3-T1181.25400.2500210NoneGoodK2M
1024F2024T10-L351.4200.2500000NoneGoodK2M
1025F1324T2-L2121.16300.300000NoneGoodK2M
1026F2024T2-T12101.2200.300000NoneGoodK2M
1027F1424T3-T1291.22200.2500310NoneGoodK2M
1028F1448T10-S181.25400.200852NoneGoodExpedium
1029M1736T3-L3121.16400.300330NoneGoodK2M
1030M1430T4-L191.22300.2500442Unhappy with pain reliefGoodK2M
1031M1536T3-T1181.25200.2200532Had low back pain (NSAIDs)GoodK2M
1032F1648T11-L341.5250.2500100NoneGoodK2M
1033F1442T4-T1171.28300.3500000NoneGoodK2M
1034F1324T4-T1061.33300.300300NoneGoodK2M
1035F1230T4-T1061.5200.2500210NoneGoodK2M

a BT blood transfusion

Results - Summary of perioperative parameters in all 35 patients a BT blood transfusion There was loss of correction by >10° in comparison with immediate postop x-ray Radiologically visible defect in the fusion mass Persistent axial back pain of intensity severe to warrant regular intake of pain-killers. Thus collected clinico-radiological data was analysed using statistical package for the social sciences v16 (SPSS Inc. IBM Corp., U.S.A). Statistical significance was set at p < 0.05.

Results

The study cohort comprised of 8 males and 27 females. The mean age at diagnosis of AIS was 10.75 years (range: 10 – 16). The mean age at surgery was 15 years (range: 11 – 21 years). The most common curve pattern at the time of surgery was structural main thoracic curve (23 patients). Double structural curve and structural thoraco-lumbar/lumbar curves comprised of nine and three patients respectively. The mean preoperative curve magnitude at the time of surgery was 60° (range: 40° – 90°)

Perioperative parameters

The results of all perioperative parameters is summarised comprehensively in Table 1. The average follow- up was 2.94 years (range: 2–4y). The mean duration of surgery was 148 min (range: 98–175 min). The VAS score was reduced from 1.71 (range: 0–8) to 0.26 at 6 months post-op (range: 0–2). The mean no. of instrumented segments was 9.4 (range: 4–13) and implant density index (IDI) averaged 1.23 (range: 1.15 – 1.50). The harvest from cell saver on recycling yielded an average of 95mls (range: 65–430mls). None of the 35 patients needed any postoperative blood transfusions. Three different instrumentation systems were used in the study population were: Expedium (1), Synergy (11) and K2M (23). The mean amount of ACTIFUSE™ used was 32mls (range: 20–60mls)

Radiographic parameters

The immediate postop Cobb angle improved to 23.2° (range: 9° – 55°) and new bone formation was seen on plain x-rays as early as 6 weeks in few patients. New bone formation was seen in all cases by 3 months postop follow-up radiographs. Loss of curve correction was seen in 19 patients and remaining 16 had improvement in final Cobb angle with time. The mean loss of Cobb angle at end of study was 2.7° (range: 1°–5°). No patient in the study group had loss of Cobb angle correction by more than 10°. The radiographic parameters in all 35 patients are summarized in Table 2. Case examples of senior author’s algorithm with three curve types (I - III) showing preoperative, immediate postoperative and final follow-up x-rays of AIS treated by PSF and use of low IDI construct (Figs 2, 3 and 4). Instrumentation system had no effect on fusion rates though the numbers were small for the three spinal implant systems used.
Table 2

Results - Summary of radiographic parameters of all 35 patients

Patient IDLevels fusedAIS Curve Type MHHN AlgorithmPre-op Cobb ^le3 months f/u Cobb ^leFinal F/U Cobb ^leTotal loss of Cobb ^leComplicationRadiographic fusionInstrumentation
1001T2-L1Type I7522253NoneGoodSynergy
1002T3-L3Type II73 & 6138 & 2526 & 31−12NoneGoodSynergy
1003T2-L2Type I562720−7NoneGoodK2M
1004T3-L1Type I571513−2NoneGoodK2M
1005T4-L2Type I783730−7NoneGoodSynergy
1006T3-L1Type I562220−2NoneGoodK2M
1007T3-L3Type I6020223MRSA deep infectionGood despite deep infectionSynergy
1008T3-L3Type I9012164NoneGoodSynergy
1009T3-T11Type II80 & 5535 & 3840 & 215NoneGoodSynergy
1010T3-T11Type I742825−3NoneGoodSynergy
1011T4-T10Type II54 & 4526 & 2827 & 251NoneGoodSynergy
1012T2-T12Type I641816−2NoneGoodK2M
1013T3-L3Type I5619201NoneGoodK2M
1014T2-T12Type II86 & 5634 & 2638 & 424NoneGoodK2M
1015T3-L1Type I602618−8NoneGoodK2M
1016T2-L1Type I602220−2NoneGoodSynergy
1017T3-T11Type II53 & 3834 & 3729 & 31−5NoneGoodK2M
1018T4-T12Type II47 & 3816 & 2620 & 204NoneGoodSynergy
1019T2-L3Type II68 & 6532 & 3530 & 322Right rod broken at T9GoodK2M
1020T2-L2Type I572016−4NoneGoodK2M
1021T4-L2Type I643225−7NoneGoodSynergy
1022T4-L2Type I5820222NoneGoodK2M
1023T3-T11Type II46 & 3621 & 2121 & 210NoneGoodK2M
1024T10-L3Type III409101NoneGoodK2M
1025T2-L2Type I5525283NoneGoodK2M
1026T2-T12Type II53 & 3717 & 1822 & 215NoneGoodK2M
1027T3-T12Type I45242NoneGoodK2M
1028T10-S1Type III4015183NoneGoodExpedium
1029T3-L3Type I6016182NoneGoodK2M
1030T4-L1Type I5520222Unhappy with pain reliefGoodK2M
1031T3-T11Type I582016−4Had low back painGoodK2M
1032T11-L3Type III502018−2NoneGoodK2M
1033T4-T11Type I501815−3NoneGoodK2M
1034T4-T10Type I5520222NoneGoodK2M
1035T4-T10Type I7055522NoneGoodK2M
Fig. 2

Structural thoracic AIS (MHHN curve type I) in 16y/♀ treated with PSF with 66 % correction showing pre-op, immediate post-op and 4 years post-op radiographs

Fig. 3

Double structural AIS (MHHN curve type II) in 15y/♀ treated by PSF of both curves. 66 % and 50 % correction of main thoracic and compensatory lumbar curves was achieved. The pre-op, immediate post-op and 2.5 years post-op radiographs are shown

Fig. 4

Double structural AIS (MHHN curve type II) in 14.5y/♀ treated with selective thoracic fusion (65 % correction) with f/u of 3.5 years showing pre-op, immediate post-op and 3.5 years follow-up radiographs

Results - Summary of radiographic parameters of all 35 patients Structural thoracic AIS (MHHN curve type I) in 16y/♀ treated with PSF with 66 % correction showing pre-op, immediate post-op and 4 years post-op radiographs Double structural AIS (MHHN curve type II) in 15y/♀ treated by PSF of both curves. 66 % and 50 % correction of main thoracic and compensatory lumbar curves was achieved. The pre-op, immediate post-op and 2.5 years post-op radiographs are shown Double structural AIS (MHHN curve type II) in 14.5y/♀ treated with selective thoracic fusion (65 % correction) with f/u of 3.5 years showing pre-op, immediate post-op and 3.5 years follow-up radiographs

Complications

There were two adverse events in our case series: Implant failure - Without any evidence of pseudarthrosis in a 16 year old female. She presented with a subcutaneously palpable implant and mechanical pain at 25 months postoperatively following a T3 – L4 PSF. Sound arthrodesis with good fusion mass was seen on CT and at revision surgery for exchange of broken rod The relevant preoperative, postoperative radiographs and at the time of revision surgery for right sided rod breakage at 26 months from index surgery are illustrated in Fig 5.
Fig. 5

Adverse event – Radiographs of AIS with right rod breakage at 25 months following T3 – L4 PSF

Adverse event – Radiographs of AIS with right rod breakage at 25 months following T3 – L4 PSF Late deep MRSA infection warranting removal of all instrumentation at 47 months post-op in a 15 year old male. Sound arthrodesis was seen at the time of implant removal and deep cultures grew MRSA (Fig 6).
Fig. 6

Late deep MRSA infection in a 15/♂ showing pre-op and 47 months post-op x-rays (i.e., immediately prior to implant removal). Solid arthrodesis was seen at implant removal and final x-rays 6 months post implant removal are depicted

Late deep MRSA infection in a 15/♂ showing pre-op and 47 months post-op x-rays (i.e., immediately prior to implant removal). Solid arthrodesis was seen at implant removal and final x-rays 6 months post implant removal are depicted

Discussion

We undertook a prospective clinical study to evaluate the therapeutic efficacy of a novel synthetic osteoconductive bone graft expander (SiCaP) for achieving arthrodesis in AIS surgeries. In this group of 35 patients, we did not observe any inflammatory response or any other adverse effects in both genders. We observed osteointegration of SiCaP with native host bone as early as 6 weeks and some evidence of radiographic fusion was seen in all patients by 3 months post-op. The ACTIFUSE™ granules remained circumscribable on plain x-rays at 9 – 12 months and were fully integrated with host bone as solid fusion mass by 24 months. Radiographic assessment of spinal fusion by plain x-rays is fraught with fallacies and may be inaccurate as they more often tend to over-estimate solid fusion (i.e., false negative for non-unions) [13]. Despite advances in imaging quality, radiographs at best are only two dimensional and dynamic radiographs though helpful in ruling out instability have their own limitations. The main shortcoming of dynamic x-rays includes measurement reliability and disagreement between observers on permissible motion [14]. Computed tomography (CT) is more sensitive in detecting non-union and is investigation of choice to confirm or rule out pseudarthrosis [15]. Three dimensional CT reconstructions are helpful in planning revision surgeries to address symptomatic pseudarthrosis. However enormous radiation exposure precludes its routine use in asymptomatic patients and is reserved for patients with persistent axial back pain and instrumentation failure. A single lumbar spine CT has the irradiation dose equivalent to 240 chest radiographs [16]. Though Magnetic resonance imaging (MRI) is appealing owing to lack of irradiation induced risks, its utility in assessing spinal fusion is inferior to CT scans [17]. Further research is needed to define the MR sequences and magnet strength required to assess spinal fusion in presence of instrumentation and its artifacts. Lerner et al. compared the osteointegration properties of beta-tricalcium phosphate (b-TCP) and silicated calcium phosphate (SiCaP) as bone graft substitutes in PSF for AIS. Unlike SiCaP, the b-TCP granules were observed to dissolve rapidly (at 6 months) and underwent faster degradation [18, 19]. Similar observations were made by Muschik who reported b-TCP granules to be invisible on radiographs at 8 ± 2 months postoperatively. This faster degradation of b-TCP produced inflammatory response in an animal model [20]. Such an inflammatory response would be detrimental for sound fusion as it can trigger bone resorption. The end volume and quality of such newly formed bone may have poor trabecular architecture and susceptible for breaks/fracture. The silicate substitution at 0.8 % in ACTIFUSE™ was observed to promote accelerated neovascularisation and bone apposition with formation of normal trabecular architecture [11, 19]. It also significantly promoted bioactivity and facilitated adaptive remodelling with better bony in-growths in comparison to hydroxyapatite (HA). We mixed SiCaP and locally harvested bone in 60:40 ratio prior to laying over the instrumented area. Posterior decortication of laminae and transverse processes exposes the bleeding cancellous bone creating an ideal environment for new bone formation facilitating linkage between native bone and bone graft substitute. Korovessis observed that HA in combination with local bone and bone marrow aspirates (BMA) did not produce satisfactory arthrodesis in postero-lateral fusion unlike SiCaP which produced consistent results and good fusion mass in similar surgeries [21]. Lerner et al. used 20 – 40mls of SiCaP mixed with locally harvested bone plus BMA from vertebral bodies in 21 patients who underwent posterior spinal fusion for AIS [19]. BMA possess osteoinductive properties and the true role of SiCaP in causing arthrodesis when mixed with such an osteogenic agent cannot be determined definitively/is questionable [22]. We did not use BMA in any of our 35 patients in this series and all but one had good/excellent arthrodesis with similar quantities of SiCaP (average 32mls). This conclusively establishes that solid fusion does happen with isolated use of SiCaP when mixed with locally harvested bone in scoliosis surgeries. Finally, the gold standard iliac crest bone graft (ICBG) was associated with significant donor site morbidity in adolescents that limited activities of daily living (ADL) in at least 21 out of 87 patients observed by Skaggs [9]. The mean VAS was 4 and up to 10 % were on regular analgesics even at 4 years post-op from the time of index surgery. They concluded that the true dimensions of pain and suffering from other complications associated with ICBG was significantly under-reported in published literature. All patients in our series were pain-free except two and had stopped all analgesics by 6 months post-op. Only 14 patients reported mild pain/discomfort at 6 months and the mean VAS score at final follow-up was 0.23 (range: 0 – 2). Only two patients had moderate pain that warranted intake of over the counter NSAIDs. Implant density index refers to the number of fixation anchors used to correct the scoliotic deformity. It is defined as the ratio of number of fixation anchors to the number of vertebral segments fused [23]. Larger the IDI, better is the degree of Cobb angle correction and lesser the loss of correction with time owing to superior fixation and enhanced pull-out strength imparted by the anchors. Constructs with IDI of <1.5 are considered to be of lower implant density and many studies have questioned the need for bilateral screws in every vertebra for AIS correction [24, 25]. There was negligible loss of Cobb angle correction at final follow-up and was within the measurement error (i.e., mean loss of correction was 2° [range: 1°–5°]) despite low IDI construct. One patient with instrumentation failure had exploration of fusion mass and exchange of broken rod for a prominent implant was found to have sound fusion at the time of revision surgery (Fig 6). The use of low IDI constructs yielded significant cost-savings without any compromise in our clinical results. The market price of 20mls of ACTIFUSE™ is equivalent to that of one pedicle screw. Utilizing the synthetic bone graft substitute for the entire study cohort amounted to the price of one and half pedicle screws (i.e., 30mls of ACTIFUSE™ = 1.5 pedicle screw in terms of cost) which was more cost-effective in-comparison to a scenario wherein one were to have used bilateral anchors at each vertebral segment. Our study was not without limitations. Firstly we did not peform any power analysis to determine the number of AIS cases treated by PSF that would be needed to detect one pseudoarthrosis. Secondly we did not perform CT scans in all patients to assess fusion and the role of CT was confined only for evaluation of symptomatic patients who had either instrumentation failure or persistent pain. Ethical considerations and hazards of irradiation of asymptomatic patients esp. in reproducible age group was the main hurdle to the same. We would not be surprised if any REC would approve such a study. Thirdly two of our patients with persistent pain used NSAIDs owing to intolerance to opioid based medications (severe itching in one and drowsiness in the other). NSAIDs consumption and nicotine comsumption would interfere would fusion rates (esp. in early phase of healing) from many well documented clinical studies [26, 27]. Consumption of nicotine (smoking/chewing) status was not collected in any of our patients owing to the reluctance of majority of teenagers to be upfront and disclose inviting wrath from their parents/care-givers. And finally we did not have a control group to evaluate the results of SiCaP used PSF vs. controls who underwent PSF. The control group would ideally be a age, curve severity and sex matched AIS patients were operated by PSF with use of ICBG. Performing such a prospective comparative study (i.e., at least a LoE II if not a randomized controlled study) is desired to truly determine the role of SiCaP in spinal deformity surgeries. This would undoubtedly be grounds for further research and this pilot study is a first step towards that goal having established the safety profile of SiCaP without any untoward adverse events with its clinical use.

Conclusion

In conclusion, SiCaP’s use was safe and it produced a predictable sound arthrodesis without any adverse effects or inflammatory response in all 35 patients in our series treated by PSF. The surgical results were equivalent or superior and consistent with published historical studies associated with use of gold standard ICBG. Use of SiCaP had distinct advantages in minimising complications reported with ICBG harvest. Use of low IDI instrumentation constructs was not associated with unacceptable (i.e., >10°) loss of correction or increase in pseudarthrosis rates at 2 years. There was substantial cost savings without any compromise in clinical outcomes.
  27 in total

1.  Treatment of scoliosis. Correction and internal fixation by spine instrumentation.

Authors:  P R HARRINGTON
Journal:  J Bone Joint Surg Am       Date:  1962-06       Impact factor: 5.284

2.  Effect of silicon level on rate, quality and progression of bone healing within silicate-substituted porous hydroxyapatite scaffolds.

Authors:  Karin A Hing; Peter A Revell; Nigel Smith; Thomas Buckland
Journal:  Biomaterials       Date:  2006-06-21       Impact factor: 12.479

3.  A critical analysis of methods of fusion for scoliosis: an evaluation in two hundred and sixty-six patients. 1958.

Authors:  John H Moe
Journal:  Clin Orthop Relat Res       Date:  2007-07       Impact factor: 4.176

4.  Natural history of posterior iliac crest bone graft donation for spinal surgery: a prospective analysis of morbidity.

Authors:  P A Robertson; A C Wray
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-01       Impact factor: 3.468

5.  Correlative radiological, self-assessment and clinical analysis of evolution in instrumented dorsal and lateral fusion for degenerative lumbar spine disease. Autograft versus coralline hydroxyapatite.

Authors:  Panagiotis Korovessis; Georgios Koureas; Spyridon Zacharatos; Zisis Papazisis; Elias Lambiris
Journal:  Eur Spine J       Date:  2005-03-24       Impact factor: 3.134

6.  Complications of posterior iliac crest bone grafting in spine surgery in children.

Authors:  D L Skaggs; M A Samuelson; J M Hale; R M Kay; V T Tolo
Journal:  Spine (Phila Pa 1976)       Date:  2000-09-15       Impact factor: 3.468

7.  Risk-factor analysis of adjacent-segment pathology requiring surgery following anterior, posterior, fusion, and nonfusion cervical spine operations: survivorship analysis of 1358 patients.

Authors:  Jae Chul Lee; Sang-Hun Lee; Colleen Peters; K Daniel Riew
Journal:  J Bone Joint Surg Am       Date:  2014-11-05       Impact factor: 5.284

8.  Assessment of bony union following surgical stabilisation for lumbar spondylolysis: a comparative study between radiography and computed tomography.

Authors:  V S Pai; B Hodgson
Journal:  J Orthop Surg (Hong Kong)       Date:  2006-04       Impact factor: 1.118

Review 9.  Evidence-based medicine analysis of all pedicle screw constructs in adolescent idiopathic scoliosis.

Authors:  Kishore Mulpuri; Angeliki Perdios; Christopher W Reilly
Journal:  Spine (Phila Pa 1976)       Date:  2007-09-01       Impact factor: 3.468

10.  Silicate-substituted calcium phosphate as a bone graft substitute in surgery for adolescent idiopathic scoliosis.

Authors:  Thomas Lerner; Ulf Liljenqvist
Journal:  Eur Spine J       Date:  2012-09-05       Impact factor: 3.134

View more
  2 in total

1.  Bone substitutes and expanders in Spine Surgery: A review of their fusion efficacies.

Authors:  Abhijeet Kadam; Paul W Millhouse; Christopher K Kepler; Kris E Radcliff; Michael G Fehlings; Michael E Janssen; Rick C Sasso; James J Benedict; Alexander R Vaccaro
Journal:  Int J Spine Surg       Date:  2016-09-22

Review 2.  Use of graft materials and biologics in spine deformity surgery: a state-of-the-art review.

Authors:  Ki-Eun Chang; Mohamed Kamal Mesregah; Zoe Fresquez; Eloise W Stanton; Zorica Buser; Jeffrey C Wang
Journal:  Spine Deform       Date:  2022-06-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.