Literature DB >> 26294001

Periprosthetic fractures: concepts of biomechanical in vitro investigations.

Eike Jakubowitz1, Jörn Bengt Seeger2.   

Abstract

PURPOSE: Experimental in vitro studies investigating periprosthetic fractures after joint replacement are used increasingly. The purpose of this review was to deliver a condensed survey of studies in order to provide researchers with an overview of relevant scientific results and their clinical relevance.
METHODS: A literature search was conducted to obtain all available papers dealing with periprosthetic fractures, with particular attention being paid to articles with an experimental research design. Study goals, scientific methods and results, their interpretation and clinical relevance were assessed and compared. The main focus was on comparability with clinical fracture patterns and physiological joint loads.
RESULTS: Excluding duplicates, 24 studies with regard to artificial hip, knee and shoulder joints were found dating back to August 2000. Almost all studies were performed quasi-statically and without consideration of muscle forces and thus reflect selected loading conditions and no dynamic situation during activities of daily living (ADL). Various experimental protocols were used, differing in the choice of experimental material, implant and fixation system and load application.
CONCLUSIONS: In vitro studies regarding periprosthetic fracture research allow controlling for disturbances, such as clinically occurring risk factors like reduced bone mineral density (BMD) or greater patient age. Notwithstanding, due to methodological differences, comparisons between studies were possible to a limited degree only. For this reason, and because of quasi-static loading typically applied, results can only be partially applied to clinical practice.

Entities:  

Keywords:  Arthroplasty; Biomechanics; Fracture load; In vitro experiments; Periprosthetic fracture

Mesh:

Year:  2015        PMID: 26294001     DOI: 10.1007/s00264-015-2954-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  46 in total

Review 1.  Classification of periprosthetic fractures complicating total knee arthroplasty.

Authors:  C H Rorabeck; J W Taylor
Journal:  Orthop Clin North Am       Date:  1999-04       Impact factor: 2.472

2.  Artificial hip prosthesis in acute and nonunion fractures of the femoral neck: follow-up study of seventy cases.

Authors:  I B HORWITZ; M I LENOBEL
Journal:  J Am Med Assoc       Date:  1954-06-05

3.  Extended sagittal saw cut significantly reduces fracture load in cementless unicompartmental knee arthroplasty compared to cemented tibia plateaus: an experimental cadaver study.

Authors:  J B Seeger; D Haas; S Jäger; E Röhner; S Tohtz; M Clarius
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

4.  Has a patient type with peri-prosthetic femoral fractures evolved?

Authors:  Matthieu Ehlinger; David Bahlau; Michel Rahme; Philippe Adam; François Bonnomet
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

Review 5.  Fractures of the femur after hip replacement.

Authors:  C P Duncan; B A Masri
Journal:  Instr Course Lect       Date:  1995

6.  Cement-in-cement revision for selected Vancouver Type B1 femoral periprosthetic fractures: a biomechanical analysis.

Authors:  Christopher J Brew; Lance J Wilson; Sarah L Whitehouse; Matthew J W Hubble; Ross W Crawford
Journal:  J Arthroplasty       Date:  2012-11-10       Impact factor: 4.757

7.  Fracture of the ipsilateral femur in patients wih total hip replacement.

Authors:  J E Johansson; R McBroom; T W Barrington; G A Hunter
Journal:  J Bone Joint Surg Am       Date:  1981-12       Impact factor: 5.284

8.  Is a valgus position of the femoral component in hip resurfacing protective against spontaneous fracture of the femoral neck?: a biomechanical study.

Authors:  C Schnurr; J Nessler; C Meyer; H H Schild; J Koebke; D P König
Journal:  J Bone Joint Surg Br       Date:  2009-04

9.  Embalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?

Authors:  Tobias Topp; Thorben Müller; Sebastian Huss; Peter Herbert Kann; Eberhard Weihe; Steffen Ruchholtz; Ralph Peter Zettl
Journal:  Acta Orthop       Date:  2012-09-14       Impact factor: 3.717

10.  Standardized loads acting in knee implants.

Authors:  Georg Bergmann; Alwina Bender; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Adam Trepczynski; Markus O Heller; Ines Kutzner
Journal:  PLoS One       Date:  2014-01-23       Impact factor: 3.240

View more
  3 in total

1.  Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis.

Authors:  Philippe Hernigou; Jean Charles Auregan; Claire Bastard; Victor Housset; Charles Henri Flouzat-Lachaniette; Arnaud Dubory
Journal:  Int Orthop       Date:  2018-03-04       Impact factor: 3.075

2.  Morphological Measurement of the Femoral Anterior Bow in Chinese Population Based on Three-Dimensional Computed Tomography.

Authors:  Yang Liu; Aobo Zhang; Rui Cai; Hao Chen; Chen Li; Qing Han; Jincheng Wang
Journal:  Biomed Res Int       Date:  2021-11-05       Impact factor: 3.411

3.  Comparison of axial-rotational postoperative periprosthetic fracture of the femur in composite osteoporotic femur versus human cadaveric specimens: A validation study.

Authors:  Jonathan N Lamb; Oliver Coltart; Isaiah Adekanmbi; Hemant G Pandit; Todd Stewart
Journal:  Proc Inst Mech Eng H       Date:  2022-05-21       Impact factor: 1.763

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.