PURPOSE: Single-legged hop tests and isokinetic muscle torque are common outcome measures in the evaluation of knee function. The reliability of the single-legged hop tests in children has not been documented. The aim was to examine inter- and intrarater reliability of four single-legged hop tests and isokinetic muscle torque measurements in children. METHODS: Twenty-eight sports-active children (12.4 ± 0.3 years old) were tested three times in two test sessions separated by 1 week. They performed four single-legged hop tests and concentric isokinetic torque measurements during knee extension and flexion. Inter- and intrarater reliability were calculated using the intraclass correlation coefficient (ICC 2,1). Relative terms of the standard error of measurement (SEM %) and smallest real difference(SRD %) were emphasized to allow comparison between the different variables. RESULTS: Twenty-six children were included for statistical analysis. ICCs for inter- and intrarater reliability were moderate to high for the hop tests (0.62-.91) and isokinetic measurements (0.76-0.87). SEMs % were low for the hop tests (3.9-7.4 %) and the isokinetic measurements (5.2-8.9 %). SRDs % were 20.5 % or less for the hop tests, 15.7 % or less for knee extension, and 24.6 % or less for knee flexion. CONCLUSION: The single-legged hop tests and isokinetic muscle torque measurements demonstrated moderate-to high reliability with low measurement error in sports-active children. A change above 20.5 % for the single-legged hop tests, 15.7 % for knee extension, and 24.6 % for knee flexion is necessary to represent a real change in knee function. Level of evidence III.
PURPOSE: Single-legged hop tests and isokinetic muscle torque are common outcome measures in the evaluation of knee function. The reliability of the single-legged hop tests in children has not been documented. The aim was to examine inter- and intrarater reliability of four single-legged hop tests and isokinetic muscle torque measurements in children. METHODS: Twenty-eight sports-active children (12.4 ± 0.3 years old) were tested three times in two test sessions separated by 1 week. They performed four single-legged hop tests and concentric isokinetic torque measurements during knee extension and flexion. Inter- and intrarater reliability were calculated using the intraclass correlation coefficient (ICC 2,1). Relative terms of the standard error of measurement (SEM %) and smallest real difference(SRD %) were emphasized to allow comparison between the different variables. RESULTS: Twenty-six children were included for statistical analysis. ICCs for inter- and intrarater reliability were moderate to high for the hop tests (0.62-.91) and isokinetic measurements (0.76-0.87). SEMs % were low for the hop tests (3.9-7.4 %) and the isokinetic measurements (5.2-8.9 %). SRDs % were 20.5 % or less for the hop tests, 15.7 % or less for knee extension, and 24.6 % or less for knee flexion. CONCLUSION: The single-legged hop tests and isokinetic muscle torque measurements demonstrated moderate-to high reliability with low measurement error in sports-active children. A change above 20.5 % for the single-legged hop tests, 15.7 % for knee extension, and 24.6 % for knee flexion is necessary to represent a real change in knee function. Level of evidence III.
Authors: Dan Turner; Holger J Schünemann; Lauren E Griffith; Dorcas E Beaton; Anne M Griffiths; Jeffrey N Critch; Gordon H Guyatt Journal: J Clin Epidemiol Date: 2009-10-01 Impact factor: 6.437
Authors: Gisela Sole; Jonas Hamrén; Stephan Milosavljevic; Helen Nicholson; S John Sullivan Journal: Arch Phys Med Rehabil Date: 2007-05 Impact factor: 3.966
Authors: Clare L Ardern; Guri Ekås; Hege Grindem; Håvard Moksnes; Allen F Anderson; Franck Chotel; Moises Cohen; Magnus Forssblad; Theodore J Ganley; Julian A Feller; Jón Karlsson; Mininder S Kocher; Robert F LaPrade; Mike McNamee; Bert Mandelbaum; Lyle Micheli; Nicholas G H Mohtadi; Bruce Reider; Justin P Roe; Romain Seil; Rainer Siebold; Holly J Silvers-Granelli; Torbjørn Soligard; Erik Witvrouw; Lars Engebretsen Journal: Orthop J Sports Med Date: 2018-03-21
Authors: Laura Muñoz-Bermejo; Jorge Pérez-Gómez; Fernando Manzano; Daniel Collado-Mateo; Santos Villafaina; José C Adsuar Journal: PLoS One Date: 2019-12-17 Impact factor: 3.240
Authors: Clare L Ardern; Guri Ranum Ekås; Hege Grindem; Håvard Moksnes; Allen F Anderson; Franck Chotel; Moises Cohen; Magnus Forssblad; Theodore J Ganley; Julian A Feller; Jón Karlsson; Minider S Kocher; Robert F LaPrade; Michael McNamee; Bert Mandelbaum; Lyle Micheli; Nicholas Mohtadi; Bruce Reider; Justin Roe; Romain Seil; Rainer Siebold; Holly J Silvers-Granelli; Torbjørn Soligard; Erik Witvrouw; Lars Engebretsen Journal: Br J Sports Med Date: 2018-02-24 Impact factor: 13.800
Authors: Kameron Shams; Christopher A DiCesare; Brian M Grawe; Eric Wall; Shital N Parikh; Marc Galloway; Katie Kitchen; Kim Barber Foss; Staci M Thomas; Alicia M Montalvo; Angelo J Colosimo; Gregory D Myer Journal: Orthop J Sports Med Date: 2019-02-15