Literature DB >> 17466732

Test-retest reliability of isokinetic knee extension and flexion.

Gisela Sole1, Jonas Hamrén, Stephan Milosavljevic, Helen Nicholson, S John Sullivan.   

Abstract

OBJECTIVE: To assess reliability of isokinetic peak torque and work for knee flexion and extension.
DESIGN: Single-group test-retest.
SETTING: University laboratory. PARTICIPANTS: Eleven men and 7 women (mean age, 21 y).
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURE: Peak torque and work for concentric and eccentric knee extension and flexion were recorded at 60 degrees/s for 3 trials on 2 occasions. Intraclass correlation coefficient model 3,1 (ICC(3,1)), standard error (SE) of measurements, and smallest real differences were calculated for the maximum and for the mean peak torque and work of the 3 repetitions.
RESULTS: Relative reliability was "very high" for peak torque and work (ICC range, >.90). The SE measurements ranged between 5% and 10% of the initial values for both peak torque and work. The smallest change that indicates a real improvement for a single subject (smallest real differences) ranged from 12% to 25% for peak torque and work variables and from 25% to 30% for the peak torque ratios.
CONCLUSIONS: Isokinetic concentric and eccentric knee extensor and flexor strength variables are reliable when measured by the same examiner in asymptomatic subjects.

Entities:  

Mesh:

Year:  2007        PMID: 17466732     DOI: 10.1016/j.apmr.2007.02.006

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  55 in total

1.  Inter- and intrarater reliability of four single-legged hop tests and isokinetic muscle torque measurements in children.

Authors:  Marianne Bakke Johnsen; Ingrid Eitzen; Håvard Moksnes; May Arna Risberg
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07       Impact factor: 4.342

2.  Effects of Lumbosacral Manipulation on Isokinetic Strength of the Knee Extensors and Flexors in Healthy Subjects: A Randomized, Controlled, Single-Blind Crossover Trial.

Authors:  Grant D Sanders; Arthur J Nitz; Mark G Abel; T Brock Symons; Robert Shapiro; W Scott Black; James W Yates
Journal:  J Chiropr Med       Date:  2015-11-06

3.  TEST-RETEST RELIABILITY OF TWO CLINICAL TESTS FOR THE ASSESSMENT OF HIP ABDUCTOR ENDURANCE IN HEALTHY FEMALES.

Authors:  Joachim Van Cant; Gregory Dumont; Laurent Pitance; Christophe Demoulin; Véronique Feipel
Journal:  Int J Sports Phys Ther       Date:  2016-02

4.  Reliability and validity of a partial weight bearing measure of lower extremity performance.

Authors:  Daniel J Cipriani; Michelle Haines; Denise O'Rand; Susan Levy
Journal:  N Am J Sports Phys Ther       Date:  2009-05

5.  Sex-related differences in joint-angle-specific functional hamstring-to-quadriceps strength ratios.

Authors:  Said El-Ashker; Brian P Carson; Francisco Ayala; Mark De Ste Croix
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-07       Impact factor: 4.342

6.  Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study.

Authors:  Erkam Kömürcü; Halil Yalçın Yüksel; Murat Ersöz; Cem Nuri Aktekin; Onur Hapa; Levent Çelebi; Ayla Akbal; Ali Biçimoğlu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

7.  Effects of Weight Loss on Lean Mass, Strength, Bone, and Aerobic Capacity.

Authors:  Edward P Weiss; Richard C Jordan; Ethel M Frese; Stewart G Albert; Dennis T Villareal
Journal:  Med Sci Sports Exerc       Date:  2017-01       Impact factor: 5.411

8.  Knee stability and movement coordination impairments: knee ligament sprain.

Authors:  David S Logerstedt; Lynn Snyder-Mackler; Richard C Ritter; Michael J Axe; Joseph J Godges
Journal:  J Orthop Sports Phys Ther       Date:  2010-04       Impact factor: 4.751

9.  Muscle strength and functional performance in patients at high risk of knee osteoarthritis: a follow-up study.

Authors:  Jonas Bloch Thorlund; Per Aagaard; Ewa M Roos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-29       Impact factor: 4.342

10.  Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength.

Authors:  Ruud H Knols; Geert Aufdemkampe; Eling D de Bruin; Daniel Uebelhart; Neil K Aaronson
Journal:  BMC Musculoskelet Disord       Date:  2009-03-09       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.