Literature DB >> 26251435

Platelet Testing is Associated with Worse Clinical Outcomes for Patients Treated with the Pipeline Embolization Device.

W Brinjikji1, G Lanzino2, H J Cloft2, A H Siddiqui3, R A Hanel4, D F Kallmes2.   

Abstract

BACKGROUND AND
PURPOSE: The necessity for platelet-inhibition testing before aneurysm treatment in patients premedicated with antiplatelet agents is controversial. Using the International Retrospective Study of Pipeline Embolization Device registry, we studied complication rates in groups of patients who underwent platelet testing and those who did not undergo platelet testing to determine if these test results were associated with improved outcomes.
MATERIALS AND METHODS: Patients in the International Retrospective Study of Pipeline Embolization Device registry with an unruptured aneurysm were categorized as those who underwent platelet testing before Pipeline embolization device treatment or those who did not. Complication rates were compared by using the Fisher exact or Pearson χ(2) test. Multivariate analysis was performed to determine if platelet function testing was independently associated with poor outcomes after adjusting for age, number of devices and aneurysms, aneurysm location and size, and practitioner and center volume.
RESULTS: Compared with the patients who received a Pipeline embolization device without platelet testing, those who underwent platelet testing and Pipeline embolization device placement experienced higher rates of intracranial hemorrhage (0 of 187 [0.0%] vs 12 of 511 [2.3%], respectively; P = .04), neurologic morbidity (4 of 187 [2.1%] vs 42 of 511 [8.2%], respectively; P < .01), and combined neurologic morbidity and mortality (6 of 187 [3.2%] vs 45 of 511 [8.8%], respectively; P = .01). More patients in the platelet testing and Pipeline embolization device group were treated with multiple devices (227 [38.0%] vs 56 [27.8] patients, respectively; P = .01). On multivariate analysis, the group of patients who underwent platelet testing and Pipeline embolization device placement had higher odds of neurologic morbidity (OR, 3.25 [95% CI, 1.10-9.61]; P = .03).
CONCLUSIONS: Platelet testing in patients who undergo Pipeline embolization device placement is associated with higher rates of morbidity. Additional prospective studies are needed to determine if and when platelet testing in these patients is appropriate.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26251435      PMCID: PMC7964853          DOI: 10.3174/ajnr.A4411

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  20 in total

Review 1.  Efficacy and safety of intensified antiplatelet therapy on the basis of platelet reactivity testing in patients after percutaneous coronary intervention: systematic review and meta-analysis.

Authors:  Dániel Aradi; András Komócsi; Matthew J Price; Thomas Cuisset; Hasan Ari; Dobri Hazarbasanov; Dietmar Trenk; Dirk Sibbing; Marco Valgimigli; Laurent Bonello
Journal:  Int J Cardiol       Date:  2012-06-15       Impact factor: 4.164

2.  Clopidogrel hyper-response and bleeding risk in neurointerventional procedures.

Authors:  C Goh; L Churilov; P Mitchell; R Dowling; B Yan
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-28       Impact factor: 3.825

Review 3.  Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis.

Authors:  Ignacio Arrese; Rosario Sarabia; Rebeca Pintado; Miguel Delgado-Rodriguez
Journal:  Neurosurgery       Date:  2013-08       Impact factor: 4.654

4.  Clopidogrel Resistance by P2Y12 Platelet Function Testing in Patients Undergoing Neuroendovascular Procedures: Incidence of Ischemic and Hemorrhagic Complications.

Authors:  Jerah D Nordeen; Alden V Patel; Robert M Darracott; Gretchen S Johns; Philipp Taussky; Rabih G Tawk; David A Miller; William D Freeman; Ricardo A Hanel
Journal:  J Vasc Interv Neurol       Date:  2013-06

Review 5.  Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis.

Authors:  Waleed Brinjikji; Mohammad H Murad; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2013-01-15       Impact factor: 7.914

6.  Thromboembolic complications with Pipeline Embolization Device placement: impact of procedure time, number of stents and pre-procedure P2Y12 reaction unit (PRU) value.

Authors:  Lee A Tan; Kiffon M Keigher; Stephan A Munich; Roham Moftakhar; Demetrius K Lopes
Journal:  J Neurointerv Surg       Date:  2014-02-19       Impact factor: 5.836

7.  Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device.

Authors:  Josser E Delgado Almandoz; Benjamin M Crandall; Jill M Scholz; Jennifer L Fease; Ruth E Anderson; Yasha Kadkhodayan; David E Tubman
Journal:  J Neurointerv Surg       Date:  2013-01-12       Impact factor: 5.836

8.  Tailoring platelet inhibition according to multiple electrode aggregometry decreases the rate of thrombotic complications after intracranial flow-diverting stent implantation.

Authors:  Ismail Oran; Celal Cinar; Halil Bozkaya; Mehmet Korkmaz
Journal:  J Neurointerv Surg       Date:  2014-04-10       Impact factor: 5.836

9.  Effect of antiplatelet therapy on thromboembolism after flow diversion with the pipeline embolization device.

Authors:  Robert S Heller; Venkata Dandamudi; Michael Lanfranchi; Adel M Malek
Journal:  J Neurosurg       Date:  2013-08-23       Impact factor: 5.115

10.  Expert position paper on the role of platelet function testing in patients undergoing percutaneous coronary intervention.

Authors:  Dániel Aradi; Robert F Storey; András Komócsi; Dietmar Trenk; Dietrich Gulba; Róbert Gábor Kiss; Steen Husted; Laurent Bonello; Dirk Sibbing; Jean-Philippe Collet; Kurt Huber
Journal:  Eur Heart J       Date:  2013-09-25       Impact factor: 29.983

View more
  12 in total

1.  A DELPHI consensus statement on antiplatelet management for intracranial stenting due to underlying atherosclerosis in the setting of mechanical thrombectomy.

Authors:  Mayank Goyal; Kirill Orlov; Mary E Jensen; Allan Taylor; Charles Majoie; Mahesh Jayaraman; Jianmin Liu; Geneviève Milot; Patrick Brouwer; Shinichi Yoshimura; Felipe Albuquerque; Adam Arthur; David Kallmes; Nobuyuki Sakai; Justin F Fraser; Raul Nogueira; Pengfei Yang; Franziska Dorn; Lucie Thibault; Jens Fiehler; René Chapot; Johanna Maria Ospel
Journal:  Neuroradiology       Date:  2020-09-24       Impact factor: 2.804

2.  Antiplatelet Management for Stent-Assisted Coiling and Flow Diversion of Ruptured Intracranial Aneurysms: A DELPHI Consensus Statement.

Authors:  J M Ospel; P Brouwer; F Dorn; A Arthur; M E Jensen; R Nogueira; R Chapot; F Albuquerque; C Majoie; M Jayaraman; A Taylor; J Liu; J Fiehler; N Sakai; K Orlov; D Kallmes; J F Fraser; L Thibault; M Goyal
Journal:  AJNR Am J Neuroradiol       Date:  2020-09-17       Impact factor: 3.825

3.  Outcome Study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU).

Authors:  D Atasoy; N Kandasamy; J Hart; J Lynch; S-H Yang; D Walsh; C Tolias; T C Booth
Journal:  AJNR Am J Neuroradiol       Date:  2019-11-14       Impact factor: 3.825

4.  Relationship between haemodynamic changes and outcomes of intracranial aneurysms after implantation of the pipeline embolisation device: a single centre study.

Authors:  Junfan Chen; Yisen Zhang; Zhongbin Tian; Wenqiang Li; Qianqian Zhang; Ying Zhang; Jian Liu; Xinjian Yang
Journal:  Interv Neuroradiol       Date:  2019-05-14       Impact factor: 1.610

5.  Flow Diverting Stents in Cerebral Small Caliber Vessels (< 2 mm) for Aneurysm Treatment : A Three Center Retrospective Study.

Authors:  Sophia Hohenstatt; Sergio L Vinci; Dominik F Vollherbst; Agostino Tessitore; Niclas Schmitt; Antonio Pitrone; Antonio A Caragliano; Mariano Velo; Markus A Möhlenbruch; Aldo Paolucci
Journal:  Clin Neuroradiol       Date:  2022-06-29       Impact factor: 3.649

6.  Safety and efficacy of antiplatelet response assay and drug adjustment in coil embolization: a propensity score analysis.

Authors:  Min Soo Kim; Kyung Il Jo; Je Young Yeon; Jong Soo Kim; Keon Ha Kim; Pyoung Jeon; Seung Chyul Hong
Journal:  Neuroradiology       Date:  2016-10-18       Impact factor: 2.804

7.  A novel treatment of a patient with a giant ruptured middle cerebral artery aneurysm by acute coiling followed by scheduled Pipeline flex placement.

Authors:  Shikai Liang; Ren Yuan; Xianli Lv
Journal:  Neuroradiol J       Date:  2020-07-16

8.  Platelet Function Testing in Neurovascular Procedures: Tool or Gimmick?

Authors:  Nicholas K Cheung; Michael W Carr; Udayan Ray; Duncan McKenzie; Jens J Froelich
Journal:  Interv Neurol       Date:  2019-02-28

9.  Safety and Efficacy of the Pipeline Embolization Device Use in the Outside Circle of Willis Located Intracranial Aneurysms: A Single-Center Experience.

Authors:  Sami Al Kasab; Waldo R Guerrero; Daichi Nakagawa; Edgar A Samaniego; Santiago Ortega-Gutierrez; David Hasan
Journal:  Interv Neurol       Date:  2019-01-16

10.  Procedural complexity independent of P2Y12 reaction unit (PRU) values is associated with acute in situ thrombosis in Pipeline flow diversion of cerebral aneurysms.

Authors:  Bowen Jiang; Matthew T Bender; Erick M Westbroek; Jessica K Campos; Li-Mei Lin; Risheng Xu; Rafael J Tamargo; Judy Huang; Geoffrey P Colby; Alexander L Coon
Journal:  Stroke Vasc Neurol       Date:  2018-04-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.