Literature DB >> 26240833

Optical measurement of dimensional parameters of the breast with subjects in prone position.

Ann-Christin Roessler1, Felix Althoff2, Florian Jaeger3, Willi Kalender1, Evelyn Wenkel4.   

Abstract

Various applications require information on breast parameters, such as breast length and volume. An optical system was designed and tested for measuring these parameters with subjects in a prone position. The study results were used for optimizing patient positioning and handling for a future breast computed tomography (BCT) system. Measurements were conducted using an optical measurement system. To test the functionality and accuracy of the system, measurements were performed using reference phantoms. Additionally, 20 women and 5 men were examined to calculate breast parameters in alternative positions and breathing states. The results of the optical measurements were compared with magnetic resonance imaging (MRI) measurements. Volume and length of the reference phantoms were determined with errors below 2%. The patient study demonstrated a mean breast volume of 530.7 ml for women during normal breathing. During an exhalation state, breast volume increased significantly by 17.7 ml in comparison with normal breathing. Differences with MRI measurements were found to be 3% for breast length and 9% for breast volume on average. The proposed optical measurement system was found to be suitable for measuring the dimensional parameters of the breast in a prone position and provides a tool for evaluating breast coverage for BCT.

Entities:  

Keywords:  breast computed tomography; breast tissue coverage; optical measurement; patient positioning

Year:  2015        PMID: 26240833      PMCID: PMC4521681          DOI: 10.1117/1.JMI.2.3.034001

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  16 in total

1.  Estimation of breast volume and its variation during the menstrual cycle using MRI and stereology.

Authors:  Z Hussain; N Roberts; G H Whitehouse; M García-Fiñana; D Percy
Journal:  Br J Radiol       Date:  1999-03       Impact factor: 3.039

2.  Practical do-it-yourself device for accurate volume measurement of breast.

Authors:  E Tezel; A Numanoğlu
Journal:  Plast Reconstr Surg       Date:  2000-03       Impact factor: 4.730

3.  Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality.

Authors:  Avice O'Connell; David L Conover; Yan Zhang; Posy Seifert; Wende Logan-Young; Chuen-Fu Linda Lin; Lawrence Sahler; Ruola Ning
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

4.  Breast volume determination in breast hypertrophy: an accurate method using two anthropomorphic measurements.

Authors:  Leif J Sigurdson; Susan A Kirkland
Journal:  Plast Reconstr Surg       Date:  2006-08       Impact factor: 4.730

5.  Measurement of breast volume with thermoplastic casts.

Authors:  A Edsander-Nord; M Wickman; G Jurell
Journal:  Scand J Plast Reconstr Surg Hand Surg       Date:  1996-06

6.  Breast volumetry using a three-dimensional surface assessment technique.

Authors:  Martin C Koch; Boris Adamietz; Sebastian M Jud; Peter A Fasching; Lothar Haeberle; Stefan Karbacher; Klaus Veit; Ruediger Schulz-Wendtland; Michael Uder; Matthias W Beckmann; Mayada R Bani; Katharina Heusinger; Christian R Loehberg; Alexander Cavallaro
Journal:  Aesthetic Plast Surg       Date:  2011-04-13       Impact factor: 2.326

7.  Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results.

Authors:  Michael Golatta; Dorothea Franz; Aba Harcos; Hans Junkermann; Geraldine Rauch; Alexander Scharf; Florian Schuetz; Christof Sohn; Joerg Heil
Journal:  Eur J Radiol       Date:  2013-03-27       Impact factor: 3.528

8.  Computed tomography for imaging the breast.

Authors:  John M Boone; Alex L C Kwan; Kai Yang; George W Burkett; Karen K Lindfors; Thomas R Nelson
Journal:  J Mammary Gland Biol Neoplasia       Date:  2006-04       Impact factor: 2.673

9.  The influence of patient positioning in breast CT on breast tissue coverage and patient comfort.

Authors:  A C Rößler; E Wenkel; F Althoff; W Kalender
Journal:  Rofo       Date:  2014-09-22

Review 10.  Breast CT.

Authors:  Stephen J Glick
Journal:  Annu Rev Biomed Eng       Date:  2007       Impact factor: 9.590

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.