Literature DB >> 26224762

Multisite Study of an Implanted Continuous Glucose Sensor Over 90 Days in Patients With Diabetes Mellitus.

Andrew Dehennis1, Mark A Mortellaro2, Sorin Ioacara3.   

Abstract

BACKGROUND: Continuous glucose monitoring (CGM), which enables real-time glucose display and trend information as well as real-time alarms, can improve glycemic control and quality of life in patients with diabetes mellitus. Previous reports have described strategies to extend the useable lifetime of a single sensor from 1-2 weeks to 28 days. The present multisite study describes the characterization of a sensing platform achieving 90 days of continuous use for a single, fully implanted sensor.
METHOD: The Senseonics CGM system is composed of a long-term implantable glucose sensor and a wearable smart transmitter. Study subjects underwent subcutaneous implantation of sensors in the upper arm. Eight-hour clinic sessions were performed every 14 days, during which sensor glucose values were compared against venous blood lab reference measurements collected every 15 minutes using mean absolute relative differences (MARDs).
RESULTS: All subjects (mean ± standard deviation age: 43.5 ± 11.0 years; with 10 sensors inserted in men and 14 in women) had type 1 diabetes mellitus. Most (22 of 24) sensors reported glucose values for the entire 90 days. The MARD value was 11.4 ± 2.7% (range, 8.1-19.5%) for reference glucose values between 40-400 mg/dl. There was no significant difference in MARD throughout the 90-day study (P = .31). No serious adverse events were noted.
CONCLUSIONS: The Senseonics CGM, composed of an implantable sensor, external smart transmitter, and smartphone app, is the first system that uses a single sensor for continuous display of accurate glucose values for 3 months.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  continuous glucose monitoring; diabetes mellitus; fluorescent sensor; hypoglycemia alarms; implantable sensors; wearable device

Mesh:

Substances:

Year:  2015        PMID: 26224762      PMCID: PMC4667337          DOI: 10.1177/1932296815596760

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  25 in total

Review 1.  The future of continuous glucose monitoring: closed loop.

Authors:  Roman Hovorka
Journal:  Curr Diabetes Rev       Date:  2008-08

2.  Standards of medical care in diabetes--2014.

Authors: 
Journal:  Diabetes Care       Date:  2014-01       Impact factor: 19.112

3.  Benefits and limitations of self-monitoring of blood glucose.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2007-01

4.  Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier.

Authors:  Daniela Bruttomesso; Anne Farret; Silvana Costa; Maria Cristina Marescotti; Monica Vettore; Angelo Avogaro; Antonio Tiengo; Chiara Dalla Man; Jerome Place; Andrea Facchinetti; Stefania Guerra; Lalo Magni; Giuseppe De Nicolao; Claudio Cobelli; Eric Renard; Alberto Maran
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

5.  The dynamics of life expectancy over the last six decades in elderly people with diabetes.

Authors:  S Ioacara; C Guja; S Fica; C Ionescu-Tirgoviste
Journal:  Diabetes Res Clin Pract       Date:  2012-11-30       Impact factor: 5.602

6.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

7.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

8.  FreeStyle Navigator Continuous Glucose Monitoring System with TRUstart algorithm, a 1-hour warm-up time.

Authors:  McGarraugh Geoffrey; Ronald Brazg; Weinstein Richard
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

Review 9.  Overcoming obstacles: new management options.

Authors:  L Heinemann
Journal:  Eur J Endocrinol       Date:  2004-10       Impact factor: 6.664

10.  Impact of self monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial.

Authors:  Andrew Farmer; Alisha Wade; Elizabeth Goyder; Patricia Yudkin; David French; Anthea Craven; Rury Holman; Ann-Louise Kinmonth; Andrew Neil
Journal:  BMJ       Date:  2007-06-25
View more
  8 in total

1.  Preliminary Evaluation of a Long-Term Intraperitoneal Glucose Sensor With Flushing Mechanism.

Authors:  Lauren M Huyett; Rowena Mittal; Howard C Zisser; Evan S Luxon; Alex Yee; Eyal Dassau; Francis J Doyle; Daniel R Burnett
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

Review 2.  Update on Clinical Utility of Continuous Glucose Monitoring in Type 1 Diabetes.

Authors:  Nalani Haviland; John Walsh; Ruth Roberts; Timothy S Bailey
Journal:  Curr Diab Rep       Date:  2016-11       Impact factor: 4.810

Review 3.  Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.

Authors:  Jort Kropff; J Hans DeVries
Journal:  Diabetes Technol Ther       Date:  2016-02       Impact factor: 6.118

Review 4.  Technologies for Diabetes Self-Monitoring: A Scoping Review and Assessment Using the REASSURED Criteria.

Authors:  Jessica Hanae Zafra-Tanaka; David Beran; Beatrice Vetter; Rangarajan Sampath; Antonio Bernabe-Ortiz
Journal:  J Diabetes Sci Technol       Date:  2021-03-09

Review 5.  Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications.

Authors:  Giacomo Cappon; Martina Vettoretti; Giovanni Sparacino; Andrea Facchinetti
Journal:  Diabetes Metab J       Date:  2019-08       Impact factor: 5.376

Review 6.  Recent Advances in Wearable Optical Sensor Automation Powered by Battery versus Skin-like Battery-Free Devices for Personal Healthcare-A Review.

Authors:  Nikolay L Kazanskiy; Muhammad A Butt; Svetlana N Khonina
Journal:  Nanomaterials (Basel)       Date:  2022-01-21       Impact factor: 5.076

7.  Interference Assessment of Various Endogenous and Exogenous Substances on the Performance of the Eversense Long-Term Implantable Continuous Glucose Monitoring System.

Authors:  Carrie Lorenz; Wendolyn Sandoval; Mark Mortellaro
Journal:  Diabetes Technol Ther       Date:  2018-03-30       Impact factor: 6.118

Review 8.  Key Enabling Technologies for Point-of-Care Diagnostics.

Authors:  Elisabetta Primiceri; Maria Serena Chiriacò; Francesca M Notarangelo; Antonio Crocamo; Diego Ardissino; Marco Cereda; Alessandro P Bramanti; Marco A Bianchessi; Gianluigi Giannelli; Giuseppe Maruccio
Journal:  Sensors (Basel)       Date:  2018-10-24       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.