Literature DB >> 26212759

Elucidating trends in revision reverse total shoulder arthroplasty procedures: a retrieval study evaluating clinical, radiographic, and functional outcomes data.

Brett P Wiater1, Erin A Baker2, Meagan R Salisbury3, Denise M Koueiter3, Kevin C Baker2, Betsy M Nolan1, J Michael Wiater4.   

Abstract

BACKGROUND: The purpose of this study was to explore relationships between damage modes in explanted reverse total shoulder arthroplasty (RTSA) components, patient and radiographic risk factors, and functional data to elucidate trends in RTSA failure.
METHODS: Fifty RTSA systems, retrieved from 44 patients, with 50 polyethylene (PE) liners, 30 glenospheres, 21 glenoid baseplates, 13 modular humeral metaphases, and 17 humeral stems, were examined for damage modes, including abrasion, burnishing, dishing, embedding, scratching, and pitting. PE liners were also analyzed for delamination and edge deformation. Charts were reviewed for patient, surgical, and functional data. Pre-revision radiographs were analyzed for scapular notching and loosening.
RESULTS: Average term of implantation was 20 months (range, 0-81 months). Metallic components exhibited abrasion, burnishing, dishing, pitting, and scratching. PE liners displayed all damage modes. Damage was exhibited on 93% of glenospheres and 100% of PE liners. Of 29 aseptic shoulders, 13 showed evidence of scapular notching and 5 of humeral loosening. There was a moderate correlation between radiographically observed implant failure or dissociation and PE embedding (r = 0.496; P < .001). There were weak and moderate correlations between scapular notching severity and PE dishing (r = 0.496; P = .006), embedding (r = 0.468; P = .010), and delamination (r = 0.384; P = .040).
CONCLUSIONS: To date, this is the largest series of retrieved RTSA components and the first to relate damage modes to radiographic and clinical data. Most damage was observed on the PE liners, on both the articular surface and rim, and glenosphere components. Correlation of retrieval findings with radiographic and clinical data may help establish predictors of prostheses at risk for failure.
Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Reverse total shoulder arthroplasty; implant damage; implant retrieval; scapular notching

Mesh:

Year:  2015        PMID: 26212759     DOI: 10.1016/j.jse.2015.06.004

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  8 in total

1.  Metallosis in shoulder arthroplasty: an integrative review of literature.

Authors:  Paritosh Gogna; Paolo Paladini; Giovanni Merolla; Carlo Alberto Augusti; De Falco Maddalena; Giuseppe Porcellini
Journal:  Musculoskelet Surg       Date:  2016-11-30

2.  Reverse shoulder arthroplasty for proximal humeral fracture in the elderly. Cemented or uncemented stem?

Authors:  Yaiza Lopiz; Carlos García-Fernandez; María Vallejo-Carrasco; Daniel Garriguez-Pérez; Loreto Achaerandio; Carmen Tesoro-Gonzalo; Fernando Marco
Journal:  Int Orthop       Date:  2022-01-16       Impact factor: 3.075

3.  Risk Factors and Complications for Revision Shoulder Arthroplasty.

Authors:  Natalie L Leong; Shelby Sumner; Ani Gowd; Gregory P Nicholson; Anthony A Romeo; Nikhil N Verma
Journal:  HSS J       Date:  2019-02-28

4.  Delta Xtend reverse shoulder arthroplasty - Results at a minimum of five years.

Authors:  Craig M Ball
Journal:  Shoulder Elbow       Date:  2019-03-06

Review 5.  The modern reverse shoulder arthroplasty and an updated systematic review for each complication: part I.

Authors:  Sarav S Shah; Benjamin T Gaal; Alexander M Roche; Surena Namdari; Brian M Grawe; Macy Lawler; Stewart Dalton; Joseph J King; Joshua Helmkamp; Grant E Garrigues; Thomas W Wright; Bradley S Schoch; Kyle Flik; Randall J Otto; Richard Jones; Andrew Jawa; Peter McCann; Joseph Abboud; Gabe Horneff; Glen Ross; Richard Friedman; Eric T Ricchetti; Douglas Boardman; Robert Z Tashjian; Lawrence V Gulotta
Journal:  JSES Int       Date:  2020-09-07

6.  Manual wheelchair use leads to a series of failed shoulder replacements: A case report and literature review.

Authors:  John G Skedros; John T Cronin; Ethan D Finlinson; Tanner D Langston; Micheal G Adondakis
Journal:  Clin Case Rep       Date:  2022-09-24

7.  Humeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty.

Authors:  Tyler J Brolin; Ryan M Cox; John G Horneff Iii; Surena Namdari; Joseph A Abboud; Kristen Nicholson; Matthew L Ramsey
Journal:  Arch Bone Jt Surg       Date:  2020-01

Review 8.  The Evolution of Reverse Total Shoulder Arthroplasty-From the First Steps to Novel Implant Designs and Surgical Techniques.

Authors:  Julia K Frank; Paul Siegert; Fabian Plachel; Philipp R Heuberer; Stephanie Huber; Jakob E Schanda
Journal:  J Clin Med       Date:  2022-03-10       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.