Literature DB >> 26207683

X-Band Rapid-Scan Electron Paramagnetic Resonance of Radiation-Induced Defects in Tooth Enamel.

Zhelin Yu1, Alexander Romanyukha2, Sandra S Eaton1, Gareth R Eaton1.   

Abstract

X-band rapid-scan electron paramagnetic resonance (EPR) spectra from tooth enamel samples irradiated with doses of 0.5, 1 and 10 Gy had substantially improved signal-to-noise relative to conventional continuous wave EPR. The radiation-induced signal in a 60 mg of a tooth enamel sample irradiated with a 0.5 Gy dose was readily characterized in spectra recorded with 34 min data acquisition times. The coefficient of variance of the calculated dose for a 1 Gy irradiated sample, based on simulation of the first-derivative spectra for three replicates as the sum of native and radiation-induced signals, was 3.9% for continuous wave and 0.4% for rapid scan.

Entities:  

Mesh:

Year:  2015        PMID: 26207683      PMCID: PMC4539305          DOI: 10.1667/rr14032.1.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  12 in total

1.  A new paradigm in personal dosimetry using LiF:Mg,Cu,P.

Authors:  J R Cassata; M Moscovitch; J E Rotunda; K J Velbeck
Journal:  Radiat Prot Dosimetry       Date:  2002       Impact factor: 0.972

2.  X-band rapid-scan EPR of nitroxyl radicals.

Authors:  Deborah G Mitchell; Richard W Quine; Mark Tseitlin; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2011-11-20       Impact factor: 2.229

3.  Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

Authors:  Alexander Romanyukha; David L King; Lisa K Kennemur
Journal:  Health Phys       Date:  2012-05       Impact factor: 1.316

Review 4.  EPR dosimetry with tooth enamel: A review.

Authors:  Paola Fattibene; Freddy Callens
Journal:  Appl Radiat Isot       Date:  2010-06-04       Impact factor: 1.513

5.  Comparison of Continuous Wave, Spin Echo, and Rapid Scan EPR of Irradiated Fused Quartz.

Authors:  Deborah G Mitchell; Richard W Quine; Mark Tseitlin; Virginia Meyer; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Meas       Date:  2011-09       Impact factor: 1.898

6.  In Vivo EPR For Dosimetry.

Authors:  Harold M Swartz; Greg Burke; M Coey; Eugene Demidenko; Ruhong Dong; Oleg Grinberg; James Hilton; Akinori Iwasaki; Piotr Lesniewski; Maciej Kmiec; Kai-Ming Lo; R Javier Nicolalde; Andres Ruuge; Yasuko Sakata; Artur Sucheta; Tadeusz Walczak; Benjamin B Williams; Chad Mitchell; Alex Romanyukha; David A Schauer
Journal:  Radiat Meas       Date:  2007-07       Impact factor: 1.898

7.  Selective saturation method for EPR dosimetry with tooth enamel.

Authors:  E A Ignatiev; A A Romanyukha; A A Koshta; A Wieser
Journal:  Appl Radiat Isot       Date:  1996-03       Impact factor: 1.513

8.  Deconvolution of sinusoidal rapid EPR scans.

Authors:  Mark Tseitlin; George A Rinard; Richard W Quine; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2010-11-26       Impact factor: 2.229

9.  Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans.

Authors:  Mark Tseitlin; Deborah G Mitchell; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2012-08-08       Impact factor: 2.229

10.  Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals.

Authors:  Deborah G Mitchell; Gerald M Rosen; Mark Tseitlin; Breanna Symmes; Sandra S Eaton; Gareth R Eaton
Journal:  Biophys J       Date:  2013-07-16       Impact factor: 4.033

View more
  3 in total

1.  Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

Authors:  J Möser; K Lips; M Tseytlin; G R Eaton; S S Eaton; A Schnegg
Journal:  J Magn Reson       Date:  2017-04-17       Impact factor: 2.229

2.  Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails.

Authors:  Hanan Elajaili; Joseph McPeak; Alexander Romanyukha; Priyanka Aggarwal; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Prot Dosimetry       Date:  2016-09-02       Impact factor: 0.972

Review 3.  Rapid-scan EPR imaging.

Authors:  Sandra S Eaton; Yilin Shi; Lukas Woodcock; Laura A Buchanan; Joseph McPeak; Richard W Quine; George A Rinard; Boris Epel; Howard J Halpern; Gareth R Eaton
Journal:  J Magn Reson       Date:  2017-07       Impact factor: 2.229

  3 in total