Literature DB >> 22469931

Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

Alexander Romanyukha1, David L King, Lisa K Kennemur.   

Abstract

After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.

Entities:  

Mesh:

Year:  2012        PMID: 22469931     DOI: 10.1097/HP.0b013e31824c9594

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  5 in total

1.  Radiation dose rates now and in the future for residents neighboring restricted areas of the Fukushima Daiichi Nuclear Power Plant.

Authors:  Kouji H Harada; Tamon Niisoe; Mie Imanaka; Tomoyuki Takahashi; Katsumi Amako; Yukiko Fujii; Masatoshi Kanameishi; Kenji Ohse; Yasumichi Nakai; Tamami Nishikawa; Yuuichi Saito; Hiroko Sakamoto; Keiko Ueyama; Kumiko Hisaki; Eiji Ohara; Tokiko Inoue; Kanako Yamamoto; Yukiyo Matsuoka; Hitomi Ohata; Kazue Toshima; Ayumi Okada; Hitomi Sato; Toyomi Kuwamori; Hiroko Tani; Reiko Suzuki; Mai Kashikura; Michiko Nezu; Yoko Miyachi; Fusako Arai; Masanori Kuwamori; Sumiko Harada; Akira Ohmori; Hirohiko Ishikawa; Akio Koizumi
Journal:  Proc Natl Acad Sci U S A       Date:  2014-02-24       Impact factor: 11.205

2.  Effect of short-term sensitivity loss in LiF:Mg,Cu,P thermoluminescent dosemeter and its implications on personnel dosimetry operations.

Authors:  Alexander Romanyukha; Jeffrey A Delzer; Matthew D Grypp; Anthony S Williams
Journal:  Radiat Prot Dosimetry       Date:  2015-03-11       Impact factor: 0.972

3.  X-Band Rapid-Scan Electron Paramagnetic Resonance of Radiation-Induced Defects in Tooth Enamel.

Authors:  Zhelin Yu; Alexander Romanyukha; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Res       Date:  2015-07-24       Impact factor: 2.841

4.  Nuclear power: is it blessing or disaster in East Asia?

Authors:  Yong Han Kim
Journal:  Iran J Public Health       Date:  2012-06-30       Impact factor: 1.429

5.  Effect of Teflon Transmittance on Sensitivity of Thermoluminescence Dosimeter Cards.

Authors:  V B Podobedov; A Romanyukha; C C Miller; A Hoy
Journal:  Health Phys       Date:  2020-06       Impact factor: 2.922

  5 in total