Literature DB >> 19735403

Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin.

T Asai1.   

Abstract

SUMMARY: Ten anaesthetists assessed the ease of tracheal intubation (time to see the glottis, to intubate the trachea and to ventilate), using the Pentax Airway Scope and Macintosh laryngoscope in a manikin, in three simulated circumstances of restricted laryngoscopy: (1) the patient lying supine on the ground; (2) the patient lying supine on the ground with the head close to a wall; (3) the patient confined to a car driver's seat. For the Pentax Airway Scope, intubation was successful (within 2 min) in all three circumstances. For the Macintosh laryngoscope, intubation was successful in all cases in circumstance (1), eight in circumstance (2), and five in circumstance (3). In circumstances (2) and (3), the Pentax Airway Scope needed significantly shorter time to see the vocal cords (median [95% confidence interval] for difference: 4.5 [0.5-9.5] s in circumstance (2), and 12.5 [7.0-32.5] s in circumstance (3)), shorter time to intubate (median [95% confidence interval] for difference: 21.0 [5.5-38.5] s in circumstance (2), and 40.5 [17.5-64.0] s in circumstance (3)), and shorter time to ventilate the lungs (median [95% confidence interval] for difference: 18. 3 [4.5-36.0] s in circumstance (2), and 47.5 [16.0-84.5] s in circumstance (3)). These results indicate that, in situations where access to the patient's head is restricted, the Pentax Airway Scope is more effective than the Macintosh laryngoscope.

Entities:  

Mesh:

Year:  2009        PMID: 19735403     DOI: 10.1111/j.1365-2044.2009.06014.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  12 in total

1.  Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Motoi Itani; Hajime Nomura; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-09-14       Impact factor: 2.078

2.  Comparison of tube-guided and guideless videolaryngoscope for tracheal intubation during chest compression in a manikin: a randomized crossover trial.

Authors:  Daisuke Okada; Nobuyasu Komasawa; Shunsuke Fujiwara; Toshiaki Minami
Journal:  J Anesth       Date:  2014-10-28       Impact factor: 2.078

3.  Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial.

Authors:  Fumihiro Ohchi; Nobuyasu Komasawa; Kentaro Imagawa; Kaori Okamoto; Toshiaki Minami
Journal:  J Anesth       Date:  2015-07-24       Impact factor: 2.078

4.  Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation.

Authors:  Hanako Kohama; Nobuyasu Komasawa; Ryusuke Ueki; Noriyasu Yamamoto; Chikara Tashiro; Yoshiroh Kaminoh; Shin-ichi Nishi
Journal:  J Anesth       Date:  2013-04-26       Impact factor: 2.078

5.  Face-to-face tracheal intubation in adult patients: a comparison of the Airtraq™, Glidescope™ and Fastrach™ devices.

Authors:  Zehra Ipek Arslan; Volkan Alparslan; Pınar Ozdal; Kamil Toker; Mine Solak
Journal:  J Anesth       Date:  2015-07-29       Impact factor: 2.078

6.  Airway management in simulated restricted access to a patient--can manikin-based studies provide relevant data?

Authors:  Anders R Nakstad; Mårten Sandberg
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2011-06-13       Impact factor: 2.953

7.  A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope.

Authors:  Hyun Young Choi; Young Min Oh; Gu Hyun Kang; Hyunggoo Kang; Yong Soo Jang; Wonhee Kim; Euichung Kim; Young Soon Cho; Hyukjoong Choi; Hyunjong Kim; Gyoung Yong Kim
Journal:  Biomed Res Int       Date:  2015-06-16       Impact factor: 3.411

8.  Rapid-Sequence Intubation in the Left-Lateral Tilt Position in a Pregnant Woman with Premature Placental Abruption Utilizing a Videolaryngoscope.

Authors:  Kenta Nakao; Nobuyasu Komasawa; Yusuke Kusaka; Toshiaki Minami
Journal:  AJP Rep       Date:  2015-02-25

9.  Evaluation of a new laryngoscope according to preparation time.

Authors:  Yasuhiko Imashuku; Hirotoshi Kitagawa; Takayoshi Mizuno
Journal:  Saudi J Anaesth       Date:  2018 Apr-Jun

10.  Comparison of Direct and Indirect Laryngoscopes in Vomitus and Hematemesis Settings: A Randomized Simulation Trial.

Authors:  Ryosuke Mihara; Nobuyasu Komasawa; Sayuri Matsunami; Toshiaki Minami
Journal:  Biomed Res Int       Date:  2015-11-05       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.