Wide-field in vivo oral OCT imaging.

Anthony M D Lee1, Lucas Cahill1, Kelly Liu1, Calum MacAulay1, Catherine Poh2, Pierre Lane1.   

Abstract

We have built a polarization-sensitive swept source Optical Coherence Tomography (OCT) instrument capable of wide-field in vivo imaging in the oral cavity. This instrument uses a hand-held side-looking fiber-optic rotary pullback catheter that can cover two dimensional tissue imaging fields approximately 2.5 mm wide by up to 90 mm length in a single image acquisition. The catheter spins at 100 Hz with pullback speeds up to 15 mm/s allowing imaging of areas up to 225 mm(2) field-of-view in seconds. A catheter sheath and two optional catheter sheath holders have been designed to allow imaging at all locations within the oral cavity. Image quality of 2-dimensional image slices through the data can be greatly enhanced by averaging over the orthogonal dimension to reduce speckle. Initial in vivo imaging results reveal a wide-field view of features such as epithelial thickness and continuity of the basement membrane that may be useful in clinic for chair-side management of oral lesions.

Entities:  

Keywords:  (170.1610) Clinical applications; (170.1850) Dentistry; (170.3890) Medical optics instrumentation; (170.4500) Optical coherence tomography; (170.4580) Optical diagnostics for medicine; (170.4940) Otolaryngology

Year:  2015        PMID: 26203389      PMCID: PMC4505717          DOI: 10.1364/BOE.6.002664

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  34 in total

1.  Measurement of epithelial thickness within the oral cavity using optical coherence tomography.

Authors:  Sven Prestin; Sacha I Rothschild; Christian Stephan Betz; Marcel Kraft
Journal:  Head Neck       Date:  2012-02-09       Impact factor: 3.147

2.  Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography.

Authors:  J F de Boer; T E Milner; M J van Gemert; J S Nelson
Journal:  Opt Lett       Date:  1997-06-15       Impact factor: 3.776

3.  Real-time multi-functional optical coherence tomography.

Authors:  Boris Park; Mark Pierce; Barry Cense; Johannes de Boer
Journal:  Opt Express       Date:  2003-04-07       Impact factor: 3.894

4.  Evaluation of oral vascular anomalies using optical coherence tomography.

Authors:  Nobuyoshi Ozawa; Yasunori Sumi; Changho Chong; Tohru Kurabayashi
Journal:  Br J Oral Maxillofac Surg       Date:  2009-04-23       Impact factor: 1.651

5.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

6.  Numerical compensation of system polarization mode dispersion in polarization-sensitive optical coherence tomography.

Authors:  Ellen Ziyi Zhang; Wang-Yuhl Oh; Martin L Villiger; Liang Chen; Brett E Bouma; Benjamin J Vakoc
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

7.  Fiber-optic polarization diversity detection for rotary probe optical coherence tomography.

Authors:  Anthony M D Lee; Hamid Pahlevaninezhad; Victor X D Yang; Stephen Lam; Calum MacAulay; Pierre Lane
Journal:  Opt Lett       Date:  2014-06-15       Impact factor: 3.776

8.  In vivo optical coherence tomography for the diagnosis of oral malignancy.

Authors:  Petra Wilder-Smith; Woong-Gyu Jung; Matthew Brenner; Kathryn Osann; Hamza Beydoun; Diana Messadi; Zhongping Chen
Journal:  Lasers Surg Med       Date:  2004       Impact factor: 4.025

9.  Three-dimensional endomicroscopy of the human colon using optical coherence tomography.

Authors:  Desmond C Adler; Chao Zhou; Tsung-Han Tsai; Joe Schmitt; Qin Huang; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Express       Date:  2009-01-19       Impact factor: 3.894

10.  Delineation of an oral cancer lesion with swept-source optical coherence tomography.

Authors:  Meng-Tsan Tsai; Hsiang-Chieh Lee; Chih-Wei Lu; Yih-Ming Wang; Cheng-Kuang Lee; C C Yang; Chun-Ping Chiang
Journal:  J Biomed Opt       Date:  2008 Jul-Aug       Impact factor: 3.170

View more
  10 in total

Review 1.  Review of optical coherence tomography in oncology.

Authors:  Jianfeng Wang; Yang Xu; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

2.  Microvascular imaging and monitoring of human oral cavity lesions in vivo by swept-source OCT-based angiography.

Authors:  Wei Wei; Woo June Choi; Ruikang K Wang
Journal:  Lasers Med Sci       Date:  2017-10-16       Impact factor: 3.161

3.  Noninvasive structural and microvascular anatomy of oral mucosae using handheld optical coherence tomography.

Authors:  Meng-Tsan Tsai; Yingdan Chen; Cheng-Yu Lee; Bo-Huei Huang; Nguyen Hoang Trung; Ya-Ju Lee; Yen-Li Wang
Journal:  Biomed Opt Express       Date:  2017-10-13       Impact factor: 3.732

4.  Human ex-vivo oral tissue imaging using spectral domain polarization sensitive optical coherence tomography.

Authors:  Priyanka Sharma; Yogesh Verma; Khageswar Sahu; Sudhir Kumar; Amit V Varma; Jyoti Kumawat; Pradeep Kumar Gupta
Journal:  Lasers Med Sci       Date:  2016-11-02       Impact factor: 3.161

5.  Assessment of the radiofrequency ablation dynamics of esophageal tissue with optical coherence tomography.

Authors:  Hsiang-Chieh Lee; Osman O Ahsen; Jonathan J Liu; Tsung-Han Tsai; Qin Huang; Hiroshi Mashimo; James G Fujimoto
Journal:  J Biomed Opt       Date:  2017-07-01       Impact factor: 3.170

6.  Measurement of Oral Epithelial Thickness by Optical Coherence Tomography.

Authors:  Dario Di Stasio; Dorina Lauritano; Hasan Iquebal; Antonio Romano; Enrica Gentile; Alberta Lucchese
Journal:  Diagnostics (Basel)       Date:  2019-08-06

7.  Low-cost, ultracompact handheld optical coherence tomography probe for in vivo oral maxillofacial tissue imaging.

Authors:  Kaiyan Li; Zihan Yang; Wenxuan Liang; Jianwei Shang; Yanmei Liang; Suiren Wan
Journal:  J Biomed Opt       Date:  2020-04       Impact factor: 3.170

8.  Influence of tissue fixation on depth-resolved birefringence of oral cavity tissue samples.

Authors:  Karol Karnowski; Qingyun Li; Anima Poudyal; Martin Villiger; Camile S Farah; David D Sampson
Journal:  J Biomed Opt       Date:  2020-09       Impact factor: 3.170

Review 9.  Noninvasive diagnostic adjuncts for the evaluation of potentially premalignant oral epithelial lesions: current limitations and future directions.

Authors:  Eric C Yang; Melody T Tan; Richard A Schwarz; Rebecca R Richards-Kortum; Ann M Gillenwater; Nadarajah Vigneswaran
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2018-03-09

Review 10.  Molecular Contrast Optical Coherence Tomography and Its Applications in Medicine.

Authors:  Ancong Wang; Wenliu Qi; Tianxin Gao; Xiaoying Tang
Journal:  Int J Mol Sci       Date:  2022-03-11       Impact factor: 5.923

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.