Dynamic heart rate measurements from video sequences.

Yong-Poh Yu1, P Raveendran2, Chern-Loon Lim3.   

Abstract

This paper shows how dynamic heart rate measurements that are typically obtained from sensors mounted near to the heart can also be obtained from video sequences. In this study, two experiments are carried out where a video camera captures the facial images of the seven subjects. The first experiment involves the measurement of subjects' increasing heart rates (79 to 150 beats per minute (BPM)) while cycling whereas the second involves falling heart beats (153 to 88 BPM). In this study, independent component analysis (ICA) is combined with mutual information to ensure accuracy is not compromised in the use of short video duration. While both experiments are going on measures of heartbeat using the Polar heart rate monitor is also taken to compare with the findings of the proposed method. Overall experimental results show the proposed method can be used to measure dynamic heart rates where the root mean square error (RMSE) and the correlation coefficient are 1.88 BPM and 0.99 respectively.

Entities:  

Keywords:  (100.0100) Image processing; (100.2960) Image analysis; (110.4155) Multiframe image processing

Year:  2015        PMID: 26203374      PMCID: PMC4505702          DOI: 10.1364/BOE.6.002466

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  15 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  An advanced detrending method with application to HRV analysis.

Authors:  Mika P Tarvainen; Perttu O Ranta-Aho; Pasi A Karjalainen
Journal:  IEEE Trans Biomed Eng       Date:  2002-02       Impact factor: 4.538

3.  Advancements in noncontact, multiparameter physiological measurements using a webcam.

Authors:  Ming-Zher Poh; Daniel J McDuff; Rosalind W Picard
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-14       Impact factor: 4.538

4.  Heart rate measurement based on a time-lapse image.

Authors:  Chihiro Takano; Yuji Ohta
Journal:  Med Eng Phys       Date:  2006-10-30       Impact factor: 2.242

5.  Contact-free measurement of cardiac pulse based on the analysis of thermal imagery.

Authors:  Marc Garbey; Nanfei Sun; Arcangelo Merla; Ioannis Pavlidis
Journal:  IEEE Trans Biomed Eng       Date:  2007-08       Impact factor: 4.538

6.  Reflection photoplethysmography of arterial-blood-volume pulses.

Authors:  J Weinmann; A Hayat; G Raviv
Journal:  Med Biol Eng Comput       Date:  1977-01       Impact factor: 2.602

Review 7.  Heart rate variability in athletes.

Authors:  André E Aubert; Bert Seps; Frank Beckers
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

8.  Comparison of three mobile devices for measuring R-R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system.

Authors:  Matthias Weippert; Mohit Kumar; Steffi Kreuzfeld; Dagmar Arndt; Annika Rieger; Regina Stoll
Journal:  Eur J Appl Physiol       Date:  2010-03-12       Impact factor: 3.078

9.  Robust efficient estimation of heart rate pulse from video.

Authors:  Shuchang Xu; Lingyun Sun; Gustavo Kunde Rohde
Journal:  Biomed Opt Express       Date:  2014-03-10       Impact factor: 3.732

10.  Abnormal heart rate characteristics before clinical diagnosis of necrotizing enterocolitis.

Authors:  M L Stone; P M Tatum; J-H Weitkamp; A B Mukherjee; J Attridge; E D McGahren; B M Rodgers; D E Lake; J R Moorman; K D Fairchild
Journal:  J Perinatol       Date:  2013-05-30       Impact factor: 2.521

View more
  7 in total

1.  Influence of a skin status on the light interaction with dermis.

Authors:  Alexei A Kamshilin; Oleg V Mamontov; Vasily T Koval; Grigory A Zayats; Roman V Romashko
Journal:  Biomed Opt Express       Date:  2015-10-08       Impact factor: 3.732

2.  Dynamic heart rate estimation using principal component analysis.

Authors:  Yong-Poh Yu; P Raveendran; Chern-Loon Lim; Ban-Hoe Kwan
Journal:  Biomed Opt Express       Date:  2015-10-29       Impact factor: 3.732

3.  Accurate measurement of the pulse wave delay with imaging photoplethysmography.

Authors:  Alexei A Kamshilin; Igor S Sidorov; Laura Babayan; Maxim A Volynsky; Rashid Giniatullin; Oleg V Mamontov
Journal:  Biomed Opt Express       Date:  2016-11-16       Impact factor: 3.732

4.  Blood pulsation measurement using cameras operating in visible light: limitations.

Authors:  Robert Koprowski
Journal:  Biomed Eng Online       Date:  2016-10-03       Impact factor: 2.819

Review 5.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

6.  Continuous Distant Measurement of the User's Heart Rate in Human-Computer Interaction Applications.

Authors:  Jaromir Przybyło
Journal:  Sensors (Basel)       Date:  2019-09-27       Impact factor: 3.576

7.  A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos.

Authors:  Chen Wang; Thierry Pun; Guillaume Chanel
Journal:  Front Bioeng Biotechnol       Date:  2018-05-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.