Literature DB >> 17074525

Heart rate measurement based on a time-lapse image.

Chihiro Takano1, Yuji Ohta.   

Abstract

Using a time-lapse image acquired from a CCD camera, we developed a non-contact and non-invasive device, which could measure both the respiratory and pulse rate simultaneously. The time-lapse image of a part of the subject's skin was consecutively captured, and the changes in the average image brightness of the region of interest (ROI) were measured for 30s. The brightness data were processed by a series of operations of interpolation as follows a first-order derivative, a low pass filter of 2 Hz, and a sixth-order auto-regressive (AR) spectral analysis. Fourteen sound and healthy female subjects (22-27 years of age) participated in the experiments. Each subject was told to keep a relaxed seating posture with no physical restriction. At the same time, heart rate was measured by a pulse oximeter and respiratory rate was measured by a thermistor placed at the external naris. Using AR spectral analysis, two clear peaks could be detected at approximately 0.3 and 1.2 Hz. The peaks were thought to correspond to the respiratory rate and the heart rate. Correlation coefficients of 0.90 and 0.93 were obtained for the measurement of heart rate and respiratory rate, respectively.

Mesh:

Year:  2006        PMID: 17074525     DOI: 10.1016/j.medengphy.2006.09.006

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  37 in total

1.  Dynamic heart rate measurements from video sequences.

Authors:  Yong-Poh Yu; P Raveendran; Chern-Loon Lim
Journal:  Biomed Opt Express       Date:  2015-06-12       Impact factor: 3.732

2.  The value of polarization in camera-based photoplethysmography.

Authors:  Alexander Trumpp; Philipp L Bauer; Stefan Rasche; Hagen Malberg; Sebastian Zaunseder
Journal:  Biomed Opt Express       Date:  2017-05-01       Impact factor: 3.732

Review 3.  Smart health monitoring systems: an overview of design and modeling.

Authors:  Mirza Mansoor Baig; Hamid Gholamhosseini
Journal:  J Med Syst       Date:  2013-01-15       Impact factor: 4.460

4.  Robust efficient estimation of heart rate pulse from video.

Authors:  Shuchang Xu; Lingyun Sun; Gustavo Kunde Rohde
Journal:  Biomed Opt Express       Date:  2014-03-10       Impact factor: 3.732

Review 5.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

6.  2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-02-12

7.  2021 ISHNE/HRS/EHRA/APHRS Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yufeng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Cardiovasc Digit Health J       Date:  2021-01-29

Review 8.  Contact-Free Pulse Signal Extraction from Human Face Videos: A Review and New Optimized Filtering Approach.

Authors:  Muhammad Waqar; Reyer Zwiggelaar; Bernard Tiddeman
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

9.  Remote measurements of heart and respiration rates for telemedicine.

Authors:  Fang Zhao; Meng Li; Yi Qian; Joe Z Tsien
Journal:  PLoS One       Date:  2013-10-08       Impact factor: 3.240

10.  Design of Secure ECG-Based Biometric Authentication in Body Area Sensor Networks.

Authors:  Steffen Peter; Bhanu Pratap Reddy; Farshad Momtaz; Tony Givargis
Journal:  Sensors (Basel)       Date:  2016-04-22       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.