Yingchao Yin1, Liping Zhang2, Zhiyong Hou3, Zongyou Yang1, Ruipeng Zhang1, Wei Chen1, Pengcheng Wang1. 1. Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Hebei, China. 2. Hebei Medical University, Hebei, China. 3. Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Hebei, China. drzyhou@gmail.com.
Abstract
PURPOSE: To propose a novel method for measuring the femoral neck torsion angle (FNTA) with femoral neck oblique axial computed tomography (CT) reconstruction. METHODS: Fifty-five patients (24 females, 31 males; mean age 48.8 years [range, 20-91 years]) were included in the study. CT scans were performed on the left femurs of 27 patients and the right femurs of the remaining 28 patients. The images were analyzed independently by two observers using oblique axial femoral neck CT reconstruction. Intra-observer and inter-observer agreement was calculated as intraclass correlation coefficient (ICC). RESULTS: FNTA can be measured with high intra-observer (ICC = 0.961) and high inter-observer (ICC = 0.982) agreement. Mean FNTA was slightly larger in women than in men, and the mean left FNTA was slightly larger than the right, but neither difference was statistically significant. CONCLUSIONS: Femoral neck oblique axial CT reconstruction can be used to obtain accurate measurement of FNTA with good reproducibility. No significant differences were found in FNTA between sexes or sides.
PURPOSE: To propose a novel method for measuring the femoral neck torsion angle (FNTA) with femoral neck oblique axial computed tomography (CT) reconstruction. METHODS: Fifty-five patients (24 females, 31 males; mean age 48.8 years [range, 20-91 years]) were included in the study. CT scans were performed on the left femurs of 27 patients and the right femurs of the remaining 28 patients. The images were analyzed independently by two observers using oblique axial femoral neck CT reconstruction. Intra-observer and inter-observer agreement was calculated as intraclass correlation coefficient (ICC). RESULTS: FNTA can be measured with high intra-observer (ICC = 0.961) and high inter-observer (ICC = 0.982) agreement. Mean FNTA was slightly larger in women than in men, and the mean left FNTA was slightly larger than the right, but neither difference was statistically significant. CONCLUSIONS: Femoral neck oblique axial CT reconstruction can be used to obtain accurate measurement of FNTA with good reproducibility. No significant differences were found in FNTA between sexes or sides.