Literature DB >> 26200153

Passivity of conventional and CAD/CAM fabricated implant frameworks.

Gabriela Monteiro de Araújo1, Danilo Gonzaga Bernardo de França1, João Paulo Silva Neto1, Gustavo Augusto Seabra Barbosa1.   

Abstract

The objective of this research was to evaluate the passivity by measuring the passive fit and strain development of frameworks screwed on abutments, made by CAD/CAM technology, and to compare these parts with samples manufactured by conventional casting. Using CAD/CAM technology, four samples were made from zirconia (Zircad) and four samples were manufactured from cobalt-chrome (CoCrcad). The control groups were four specimens of cobalt-chrome, made by one-piece casting (CoCrci), with a total of 12 frameworks. To evaluate the passive fit, the vertical misfit at the abutment-framework interface was measured with scanning electron microscopy (250×) when only one screw was tightened. The mean strain in these frameworks was analyzed by photoelasticity test. A significant difference in the passive fit was observed between the control and sample groups. CoCrcad exhibited the best value of passive fit (48.76±13.45 µm) and CoCrci the worst (187.55±103.63 µm); Zircad presented an intermediate value (103.81±43.15 µm). When compared to the other groups, CoCrci showed the highest average stress around the implants (17.19±7.22 kPa). It was concluded that CAD/CAM-fabricated frameworks exhibited better passivity compared with conventionally fabricated frameworks. CAD/CAM-fabricated Co-Cr frameworks may exhibit better passive fit compared with CAD/CAM-fabricated zirconia frameworks. Even so, similar levels of stress were achieved for CAD/CAM-fabricated frameworks.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26200153     DOI: 10.1590/0103-6440201300145

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  9 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses.

Authors:  Fellwa AlRasheed; Khalid AlWazzan
Journal:  Saudi Dent J       Date:  2022-04-02

3.  The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy.

Authors:  Mitra Farzin; Rashin Giti; Amin Asalforush-Rezaiye
Journal:  Materials (Basel)       Date:  2018-03-22       Impact factor: 3.623

4.  Evaluation of Marginal Misfit of Metal Frameworks Welded by Gas-Torch, Laser, and Tungsten Inert Gas Methods.

Authors:  Wilson Matsumoto; Paula Pastana Beraldo; Rossana Pereira de Almeida; Ana Paula Macedo; Beatriz Roque Kubata; Takami Hirono Hotta
Journal:  Int J Dent       Date:  2018-10-30

Review 5.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

6.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

7.  Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques.

Authors:  Ying Zhou; Yong Li; Xiao Ma; Yiqing Huang; Jiawei Wang
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

8.  Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings.

Authors:  Matthias Rödiger; Lea Schneider; Sven Rinke
Journal:  Biomed Res Int       Date:  2018-03-22       Impact factor: 3.411

9.  Effect of Implant Platform Connection and Abutment Material on Removal Torque and Implant Hexagon Plastic Deformation.

Authors:  Paulo Henrique de Souza Pereira; Marina Amaral; Kusai Baroudi; Rafael Pino Vitti; Mohammad Zakaria Nassani; Laís Regiane da Silva-Concílio
Journal:  Eur J Dent       Date:  2019-12-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.