Literature DB >> 26189379

Effect of intraocular lens glistening size on visual quality.

Bradley S Henriksen1, Krista Kinard1, Randall J Olson2.   

Abstract

PURPOSE: To determine whether intraocular glistenings have an impact on light scatter and visual function.
SETTING: John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, USA.
DESIGN: Retrospective cohort study.
METHODS: Pseudophakic patients with visual acuity no worse than 0.02 logMAR and no ocular pathology were enrolled. All had received a single-piece high-refractive-index acrylic intraocular lens (IOL). All IOLs were photographed, and glistenings were analyzed for size and density. Outcome measures included logMAR corrected distance visual acuity (CDVA), mesopic 10% contrast logMAR CDVA with and without glare, and straylight determination with a straylight meter (C Quant log).
RESULTS: All 79 patients had glistenings within 2 diameter groups: 6 to 25 μm and over 25 μm. Linear regression for the nonstratified group was significant for IOL glistening size versus contrast visual acuity with glare. Linear regression for the 6 to 25 μm group was significant for a measure of severity index (%area) versus the straylight meter measurements, %area/size versus straylight meter measurements, IOL age versus CDVA, IOL age versus contrast visual acuity, and IOL age versus contrast visual acuity with glare. Linear regression for the over 25 μm group was significant for IOL age versus glistening size and %area/size versus contrast visual acuity, and density versus CDVA and contrast visual acuity with glare.
CONCLUSIONS: Glistening %area, at a key size, correlated with random light scatter. The age of the IOL likely affects glistening size and visual parameters. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26189379     DOI: 10.1016/j.jcrs.2014.09.051

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Effects of intraocular lens glistenings on visual function: a prospective study and presentation of a new glistenings grading methodology.

Authors:  Nick Stanojcic; David P S O'Brart; Nick Maycock; Chistopher C Hull
Journal:  BMJ Open Ophthalmol       Date:  2019-04-01

2.  Influence of intraocular lens subsurface nanoglistenings on functional visual acuity.

Authors:  Takahiro Hiraoka; Kazunori Miyata; Takeshi Hayashidera; Masaharu Iida; Keita Takada; Keiichiro Minami; Tetsuro Oshika
Journal:  PLoS One       Date:  2017-03-22       Impact factor: 3.240

Review 3.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

4.  Polarized glasses may help in symptomatic cases of intraocular lens glistenings.

Authors:  Andreas F Borkenstein; Eva-Maria Borkenstein
Journal:  Clin Optom (Auckl)       Date:  2019-05-06

5.  Reply to letter from Drs. Piotr Kanclerz and Andrzej Grzybowski entitled "Glistenings might be associated with disability glare".

Authors:  Nick Stanojcic; Christopher Hull; David P S O'Brart
Journal:  Eur J Ophthalmol       Date:  2021-11-10       Impact factor: 2.597

6.  Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y).

Authors:  Andreas F Borkenstein; Eva-Maria Borkenstein
Journal:  Clin Ophthalmol       Date:  2018-07-05

7.  Comparison of glistenings formation and their effect on forward light scatter between the Acrysof SN60WF and Eternity Natural Uni NW-60 intraocular lenses.

Authors:  Eva Philippaki; David P O'Brart; Chistopher C Hull
Journal:  BMJ Open Ophthalmol       Date:  2020-02-12

8.  The assessment of the impact of glistening on visual performance in relation to tear film quality.

Authors:  Amanda Argay; Peter Vamosi
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

9.  Outcomes of a multicenter U.S. clinical trial of a new monofocal single-piece hydrophobic acrylic IOL.

Authors:  Steven C Schallhorn; Michael Bonilla; Seth M Pantanelli
Journal:  J Cataract Refract Surg       Date:  2022-03-25       Impact factor: 3.528

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.