Literature DB >> 26187214

Appropriately regularized OSEM can improve the reconstructed PET images of data with low count statistics.

Konstantinos Karaoglanis1, Irene Polycarpou, Nikos Efthimiou, Charalampos Tsoumpas.   

Abstract

OBJECTIVE: With the increasing number of patients undergoing positron emission tomography (PET) scans and the fact that multiple whole body acquisitions are performed during therapy monitoring, the reduction of scan time as well as of the injected radioactive dose are important issues. However, short scan time and reduction of the injected radiation dose result in low count statistics, which significantly affects the quality of the reconstructed images and accurate diagnosis. SUBJECTS AND METHODS: The aim of this study was to explore the effect of low count statistics on ordered subset expectation maximization regularized with median root prior (OS-MRP-OSL) reconstructed images. By optimizing OS-MRP-OSL we determine whether a satisfactory handling of the noise properties and bias can be achieved compared to post-filtered ordered subset expectation maximization (OSEM), which will lead to improved image quality in simulations with more noise. We used realistic simulated PET data of a thorax with lesions corresponding to tumors with different intensities.
RESULTS: OS-MRP-OSL provided reduced noise from post-filtered OSEM, without having the negative effect of blurring. On the other hand, bias presented no significant difference.
CONCLUSION: This work is relevant to future PET reconstruction of clinical images and PET-magnetic resonance investigations where the reduced injected dose will allow imaging a larger cohort of humans.

Entities:  

Mesh:

Year:  2015        PMID: 26187214     DOI: 10.1967/s002449910209

Source DB:  PubMed          Journal:  Hell J Nucl Med        ISSN: 1790-5427            Impact factor:   1.102


  3 in total

Review 1.  Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

Authors:  Nicolas A Karakatsanis; Eleni Fokou; Charalampos Tsoumpas
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

2.  An improved patch-based regularization method for PET image reconstruction.

Authors:  Juan Gao; Qiegen Liu; Chao Zhou; Weiguang Zhang; Qian Wan; Chenxi Hu; Zheng Gu; Dong Liang; Xin Liu; Yongfeng Yang; Hairong Zheng; Zhanli Hu; Na Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-02

3.  Bias evaluation and reduction in 3D OP-OSEM reconstruction in dynamic equilibrium PET studies with 11C-labeled for binding potential analysis.

Authors:  Cláudia Régio Brambilla; Jürgen Scheins; Ahlam Issa; Lutz Tellmann; Hans Herzog; Elena Rota Kops; N Jon Shah; Irene Neuner; Christoph W Lerche
Journal:  PLoS One       Date:  2021-01-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.