Product ion scanning using a Q-q-Q linear ion trap (Q TRAP) mass spectrometer.

James W Hager1, J C Yves Le Blanc.   

Abstract

The use of a Q-q-Q(linear ion trap) instrument to obtain product ion spectra is described. The instrument is based on the ion path of a triple quadrupole mass spectrometer with Q3 operable as either a conventional RF/DC quadrupole mass filter or a linear ion trap mass spectrometer with axial ion ejection. This unique ion optical arrangement allows de-coupling of precursor ion isolation and fragmentation from the ion trap itself. The result is a high sensitivity tandem mass spectrometer with triple quadrupole fragmentation patterns and no inherent low mass cut-off. The use of the entrance RF-only section of the instrument as accumulation ion trap while the linear ion trap mass spectrometer is scanning enhances duty cycles and results in increased sensitivities by as much as a factor of 20. The instrument is also capable of all of the triple quadrupole scans including multiple-reaction monitoring (MRM) as well as precursor and constant neutral loss scanning. The high product ion scanning sensitivity allows the recording of useful product ion spectra near the MRM limit of quantitation. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12720286     DOI: 10.1002/rcm.1020

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  25 in total

1.  Mass spectrometry-based detection and quantification of plasma glycoproteins using selective reaction monitoring.

Authors:  Yeoun Jin Kim; Zaya Zaidi-Ainouch; Sebastien Gallien; Bruno Domon
Journal:  Nat Protoc       Date:  2012-04-12       Impact factor: 13.491

2.  Scanwave: a new approach to enhancing spectral data on a tandem quadrupole mass spectrometer.

Authors:  Daniel J Kenny; Kenneth R Worthington; John B Hoyes
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-16       Impact factor: 3.109

3.  Mutual storage mode ion/ion reactions in a hybrid linear ion trap.

Authors:  Yu Xia; Jin Wu; Scott A McLuckey; Frank A Londry; James W Hager
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

4.  Multiple neutral loss monitoring (MNM): a multiplexed method for post-translational modification screening.

Authors:  Michael D Hoffman; Matthew J Sniatynski; Jason C Rogalski; J C Yves Le Blanc; Juergen Kast
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-27       Impact factor: 3.109

5.  Advances in proteomic workflows for systems biology.

Authors:  Johan Malmström; Hookeun Lee; Ruedi Aebersold
Journal:  Curr Opin Biotechnol       Date:  2007-08-14       Impact factor: 9.740

6.  Optimized Orbitrap HCD for quantitative analysis of phosphopeptides.

Authors:  Yi Zhang; Scott B Ficarro; Shaojuan Li; Jarrod A Marto
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-28       Impact factor: 3.109

7.  Extending the Ion Capacity of a Linear Ion Trap Using Nonlinear Radio Frequency Fields.

Authors:  Mircea Guna
Journal:  J Am Soc Mass Spectrom       Date:  2015-07-16       Impact factor: 3.109

8.  Targeted proteomic quantification on quadrupole-orbitrap mass spectrometer.

Authors:  Sebastien Gallien; Elodie Duriez; Catharina Crone; Markus Kellmann; Thomas Moehring; Bruno Domon
Journal:  Mol Cell Proteomics       Date:  2012-09-07       Impact factor: 5.911

Review 9.  Bile acids: analysis in biological fluids and tissues.

Authors:  William J Griffiths; Jan Sjövall
Journal:  J Lipid Res       Date:  2010-01       Impact factor: 5.922

10.  Selected reaction monitoring to differentiate and relatively quantitate isomers of sulfated and unsulfated core 1 O-glycans from salivary MUC7 protein in rheumatoid arthritis.

Authors:  Sarah A Flowers; Liaqat Ali; Catherine S Lane; Magnus Olin; Niclas G Karlsson
Journal:  Mol Cell Proteomics       Date:  2013-03-01       Impact factor: 5.911

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.