Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models.

J R Anderson1, J J H Ackerman2, J R Garbow3.   

Abstract

Two semipermeable, hollow fiber phantoms for the validation of perfusion-sensitive magnetic resonance methods and signal models are described. Semipermeable hollow fibers harvested from a standard commercial hemodialysis cartridge serve to mimic tissue capillary function. Flow of aqueous media through the fiber lumen is achieved with a laboratory-grade peristaltic pump. Diffusion of water and solute species (e.g., Gd-based contrast agent) occurs across the fiber wall, allowing exchange between the lumen and the extralumenal space. Phantom design attributes include: i) small physical size, ii) easy and low-cost construction, iii) definable compartment volumes, and iv) experimental control over media content and flow rate.

Entities:  

Keywords:  MR phantom design; dialyzer; hollow fiber bioreactor; perfusion; semipermeable hollow fiber

Year:  2011        PMID: 26167136      PMCID: PMC4497530          DOI: 10.1002/cmr.b.20202

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  15 in total

1.  Use of (1)H NMR to study transport processes in porous biosystems.

Authors:  H Van As; P Lens
Journal:  J Ind Microbiol Biotechnol       Date:  2001-01       Impact factor: 3.346

2.  Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: a magnetic resonance imaging study.

Authors:  Churn K Poh; Peter A Hardy; Zhijie Liao; Zhongping Huang; William R Clark; Dayong Gao
Journal:  ASAIO J       Date:  2003 Jul-Aug       Impact factor: 2.872

3.  Effect of flow baffles on the dialysate flow distribution of hollow-fiber hemodialyzers: a nonintrusive experimental study using MRI.

Authors:  Churn K Poh; Peter A Hardy; Zhijie Liao; Zhongping Huang; William R Clark; Dayong Gao
Journal:  J Biomech Eng       Date:  2003-08       Impact factor: 2.097

4.  Use of magnetic resonance imaging to analyze the performance of hollow-fiber bioreactors.

Authors:  C Donoghue; M Brideau; P Newcomer; B Pangrle; D DiBiasio; E Walsh; S Moore
Journal:  Ann N Y Acad Sci       Date:  1992-10-13       Impact factor: 5.691

5.  Gd-BOPTA transport into rat hepatocytes: pharmacokinetic analysis of dynamic magnetic resonance images using a hollow-fiber bioreactor.

Authors:  Corinne Planchamp; Marianne Gex-Fabry; Christophe Dornier; Rafael Quadri; Marianne Reist; Marko K Ivancevic; Jean-Paul Vallée; Sibylle Pochon; François Terrier; Luc Balant; Bruno Stieger; Peter J Meier; Catherine M Pastor
Journal:  Invest Radiol       Date:  2004-08       Impact factor: 6.016

6.  Proton magnetic resonance imaging of flow motion of heavy water injected into a hollow fiber dialyzer filled with saline.

Authors:  T Osuga; T Obata; H Ikehira
Journal:  Magn Reson Imaging       Date:  2004-04       Impact factor: 2.546

7.  Uncovering of intracellular water in cultured cells.

Authors:  Jean-Philippe Galons; Silvia Lope-Piedrafita; Joseph L Divijak; Curt Corum; Robert J Gillies; Theodore P Trouard
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

8.  Measurement of bioreactor perfusion using dynamic contrast agent-enhanced magnetic resonance imaging.

Authors:  P E Thelwall; A A Neves; K M Brindle
Journal:  Biotechnol Bioeng       Date:  2001-12-20       Impact factor: 4.530

9.  MRI and fluorescence microscopy of the acute vascular response to VEGF165: vasodilation, hyper-permeability and lymphatic uptake, followed by rapid inactivation of the growth factor.

Authors:  Hagit Dafni; Limor Landsman; Bilha Schechter; Fortune Kohen; Michal Neeman
Journal:  NMR Biomed       Date:  2002-04       Impact factor: 4.044

10.  Diffusion effects on longitudinal relaxation in poorly mixed compartments.

Authors:  J R Anderson; Q Ye; J J Neil; J J H Ackerman; J R Garbow
Journal:  J Magn Reson       Date:  2011-04-01       Impact factor: 2.229

View more
  1 in total

1.  Quantitative imaging: systematic review of perfusion/flow phantoms.

Authors:  Marije E Kamphuis; Marcel J W Greuter; Riemer H J A Slart; Cornelis H Slump
Journal:  Eur Radiol Exp       Date:  2020-03-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.