Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: a magnetic resonance imaging study.

Churn K Poh1, Peter A Hardy, Zhijie Liao, Zhongping Huang, William R Clark, Dayong Gao.   

Abstract

Blood side and dialysate side flow distributions play an important role in determining the optimal use of dialysis membrane in hemodialyzers for the removal of uremic solutes. In this article, we used two nonintrusive magnetic resonance imaging (MRI) techniques called the two-dimensional phase contrast (2DPC) and two-dimensional Fourier transform (2DFT) velocity imaging techniques to (1) study the effect of space yarns on the dialysate side flow distribution, (2) investigate the effect of flow baffle on the dialysate side flow distribution, and (3) characterize the blood side and dialysate side flow profiles of hemodialyzers with flow rates ranging from 200 to 1000 ml/min. We investigated two types of hollow fiber hemodialyzers: hemodialyzers A (with spacer yarns) and B (without spacer yarns). We used a 3 mmol cupric sulfate solution as the compartmental fluid and imaged five transverse cross sections of these hemodialyzers. The hemodialyzer with spacer yarns had a more uniform dialysate side spatial flow distribution than that without spacer yarns. In addition, the design of flow baffle in these hemodialyzers can be further improved to promote uniform dialysate side flow distribution, and the blood side flow had a fully developed laminar flow profile. Our experimental results showed that these velocity imaging techniques provide an innovative, nonintrusive tool for characterizing flow distribution in hemodialyzers.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918588

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Design and assessment of the new APS dialyzer (APS-SA series).

Authors:  Makoto Fukuda; Miwa Miyazaki; Satoshi Uezumi; Makoto Yoshida
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

2.  Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

Authors:  Makoto Fukuda; Kengo Yoshimura; Koki Namekawa; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2017-01-13       Impact factor: 1.731

3.  Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models.

Authors:  J R Anderson; J J H Ackerman; J R Garbow
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-08       Impact factor: 1.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.