Literature DB >> 26158029

Detection of the spatial accuracy of a magnetic resonance and surgical computed tomography scanner in the region of surgical interest.

Tapani Koivukangas1, Jani Katisko2, John Koivukangas3.   

Abstract

In image-guided surgeries (IGSs) and radiology, images are the main source of information. As image data provide the differentiation between normal and abnormal tissues in the human, the images need to be reliable and they need to provide accurate spatial representation of the patient. This research concentrates on the accuracy assessment of IGS devices in general and then specifically on the spatial accuracy of a common magnetic resonance (MR) imager and a mobile three-dimensional surgical computed tomography (CT) scanner. The accuracy assessment tool had been designed to be universal and to enable its use in the hospital setting. In this study, it was used in detecting the spatial accuracy of a commercial surgical CT scanner, the O-arm, and a 1.5-T MR imager. The results show the tendency of magnetic resonance imaging to produce slight decreases in spatial accuracy toward the fringes of the images from the isocenter. Furthermore, the results indicate that the accuracy of both scanners was within pixel size and thus highly accurate in the region of surgical interest of this study.

Entities:  

Keywords:  O-arm; computed tomography; image artifact; image evaluation; magnetic resonance imaging; region of surgical interest; spatial accuracy

Year:  2014        PMID: 26158029      PMCID: PMC4478867          DOI: 10.1117/1.JMI.1.1.015502

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  10 in total

Review 1.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

Review 2.  Principles of CT and CT technology.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-09

Review 3.  The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

Authors:  J F Schenck
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

Review 4.  Innovations in minimalism: intraoperative MRI.

Authors:  E Alexander; T M Moriarty; R Kikinis; F A Jolesz
Journal:  Clin Neurosurg       Date:  1996

5.  Stereotactic operations using the o-arm.

Authors:  Jani Petri Antton Katisko; Mikko Tapio Kauppinen; John Pertti Koivukangas; Esa Raimo Heikkinen
Journal:  Stereotact Funct Neurosurg       Date:  2012-10-17       Impact factor: 1.875

6.  Magnetic resonance image-directed stereotactic neurosurgery: use of image fusion with computerized tomography to enhance spatial accuracy.

Authors:  E Alexander; H M Kooy; M van Herk; M Schwartz; P D Barnes; N Tarbell; R V Mulkern; E J Holupka; J S Loeffler
Journal:  J Neurosurg       Date:  1995-08       Impact factor: 5.115

7.  Magnetic resonance imaging. Part I--physical principles.

Authors:  W R Hendee; C J Morgan
Journal:  West J Med       Date:  1984-10

8.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

9.  Ultrasound-controlled neuronavigator-guided brain surgery.

Authors:  J Koivukangas; Y Louhisalmi; J Alakuijala; J Oikarinen
Journal:  J Neurosurg       Date:  1993-07       Impact factor: 5.115

10.  An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

Authors:  C Yu; Z Petrovich; M L Apuzzo; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  10 in total
  2 in total

1.  MRI Identification of the Osseous Extent of Pediatric Bone Sarcomas.

Authors:  Matthew J Thompson; John C Shapton; Stephanie E Punt; Christopher N Johnson; Ernest U Conrad
Journal:  Clin Orthop Relat Res       Date:  2018-03       Impact factor: 4.176

2.  The fascicular anatomy and peak force capabilities of the sternocleidomastoid muscle.

Authors:  Ewan Kennedy; Michael Albert; Helen Nicholson
Journal:  Surg Radiol Anat       Date:  2016-11-02       Impact factor: 1.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.