Literature DB >> 28571257

Comparative Assessment of Canal Transportation and Centering Ability of Reciproc and One Shape File Systems Using CBCT-An In Vitro Study.

Anika Mittal1, Shifali Dadu2, Neetu Sharma Singh3, Sarita Singh3, Bhupesh Gupta2, Anju Abraham4, Bidya Yendrembam4, Shilpa Kumari4.   

Abstract

INTRODUCTION: Root canal preparation leads to deviation of the canal anatomy causing canal transportation which affects the success of the treatment. Cone Beam Computed Tomography (CBCT) is a non invasive imaging technique to analyse the shape of the root canal before and after the preparation. AIM: The purpose of this study was to investigate and evaluate the canal transportation in curved mandibular molar root canals and centering ability of Reciproc and One Shape file systems after instrumentation using CBCT.
MATERIALS AND METHODS: Twenty mandibular molars were taken and allocated into two groups (n=10): Group 1-One Shape and Group 2-Reciproc. The canals were then scanned using CS 3D CBCT scanner (Carestream) before and after preparation, to assess the transportation and centering values at different levels respectively from the apex. The data gathered were then assessed statistically with Mann-Whitney test.
RESULTS: Analysis revealed that Reciproc and One Shape showed statistically no significant difference in terms of canal transportation and centering ability (p>0.05).
CONCLUSION: One shape and Reciproc performed similar in terms of canal transportation & centering ability.

Entities:  

Keywords:  NiTi; Reciprocating; Root canal preparation; Shaping ability; Single file

Year:  2017        PMID: 28571257      PMCID: PMC5449913          DOI: 10.7860/JCDR/2017/24257.9660

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  19 in total

1.  Advantages and disadvantages of new torque-controlled endodontic motors and low-torque NiTi rotary instrumentation.

Authors:  G Gambarini
Journal:  Aust Endod J       Date:  2001-12       Impact factor: 1.659

2.  Assessment of the deviation after biomechanical preparation of the coronal, middle, and apical thirds of root canals instrumented with three HERO rotary systems.

Authors:  Andréa Cruz Câmara; Carlos Menezes Aguiar; Jose Antonio Poli de Figueiredo
Journal:  J Endod       Date:  2007-12       Impact factor: 4.171

3.  Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography.

Authors:  J M Gambill; M Alder; C E del Rio
Journal:  J Endod       Date:  1996-07       Impact factor: 4.171

4.  Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.

Authors:  Sebastian Bürklein; Polymnia Tsotsis; Edgar Schäfer
Journal:  J Endod       Date:  2013-01-26       Impact factor: 4.171

5.  Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth.

Authors:  S E D M Saber; M M Nagy; E Schäfer
Journal:  Int Endod J       Date:  2014-04-18       Impact factor: 5.264

6.  Cleaning and shaping the root canal.

Authors:  H Schilder
Journal:  Dent Clin North Am       Date:  1974-04

7.  Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals.

Authors:  Ismail Davut Capar; Huseyin Ertas; Evren Ok; Hakan Arslan; Elif Tarim Ertas
Journal:  J Endod       Date:  2013-11-07       Impact factor: 4.171

8.  Geometric analysis of root canals prepared by four rotary NiTi shaping systems.

Authors:  Ahmed Abdel Rahman Hashem; Angie Galal Ghoneim; Reem Ahmed Lutfy; Manar Yehia Foda; Gihan Abdel Fatah Omar
Journal:  J Endod       Date:  2012-05-11       Impact factor: 4.171

9.  Clinical considerations in the diagnosis and treatment of intra-alveolar root fractures.

Authors:  I B Bender; J B Freedland
Journal:  J Am Dent Assoc       Date:  1983-10       Impact factor: 3.634

10.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01
View more
  1 in total

1.  Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems.

Authors:  Pelin Tufenkci; Kaan Orhan; Berkan Celikten; Burak Bilecenoglu; Gurkan Gur; Semra Sevimay
Journal:  Restor Dent Endod       Date:  2020-05-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.