Literature DB >> 26155467

Morphometric Analysis of Axis and Its Clinical Significance -An Anatomical Study of Indian Human Axis Vertebrae.

Mukesh Singla1, Prabhat Goel2, Mohd Salahuddin Ansari3, K S Ravi3, Satyam Khare4.   

Abstract

BACKGROUND: The atlas and axis vertebra have unique shape and complex relationship with vertebral artery. Fracture of dens of axis accounts for 7-27% of all cervical spine fractures, but surgeries in these regions are highly risky because of the reported incidences of vertebral artery injury. AIM AND
OBJECTIVES: The study was designed to measure morphometric data of human axis vertebra, of Indian origin. The different anatomical parameters on dry specimen of human axis vertebrae were established and the results were compared with other studies.
MATERIALS AND METHODS: Thirty intact human axis vertebrae were measured with digital vernier caliper and mini-inclinometer. Various linear and angular parameters of axis were observed.
RESULTS: The mean distance from the midline of body to the tip of transverse process of axis was 29.32 mm on right side and 29.06mm on left side. The mean distance from the midline of body to the lateral most edge of superior articulating facet was 22.8 mm on right side and 22.6 mm on left side. The mean value of anterior and posterior height of axis was 34.33±2.69mm and 30.56±2.78mm respectively. The anterior and posterior height of body of axis was 19.67 mm and 16.67mm respectively. Mean A-P and transverse diameter of inferior surface of axis was 15.42mm and 17.7mm respectively. Mean transverse diameter and mean A-P diameter of odontoid process was 9.32 mm and 10.1 mm respectively. Mean anterior and posterior height of the odontoid process was 14.66 mm and 13.89mm respectively. Mean of dens axis sagittal angle (angle between an axis that was imagined to pass longitudinally through the dens axis and the vertical line on a sagittal plane) was 13.23 degree. The shape of superior articulating facets of C2 varies from oval to circular. In the present study, 84% of SAF were oval and 16% were circular. Inferior articulating facets were circular in shape in 90% cases, and oval in 10% vertebra. Mean pedicle width was 10.07mm on right side and 10.52mm on left side. Mean transverse diameter of vertebral canal was 22.37±1.73mm. Mean of A-P diameter of vertebral canal at inlet was 18.31±2.05mm and mean of A-P diameter of vertebral canal at outlet was 14.84±1.63mm.
CONCLUSION: These results obtained from this study may be helpful for the surgeons in avoiding and minimizing complications such as vertebral artery injury, cranial nerve damage and injury to other vital structures while doing surgery around cranio-vertebral region.

Entities:  

Keywords:  Axis; Dens; Inferior articulating facet; Morphometry; Superior articulating facet

Year:  2015        PMID: 26155467      PMCID: PMC4484059          DOI: 10.7860/JCDR/2015/13118.5931

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  14 in total

1.  Morphology of the dens. A quantitative study.

Authors:  M B Schaffler; M D Alson; J G Heller; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  1992-07       Impact factor: 3.468

2.  Morphologic characteristics of human cervical pedicles.

Authors:  E E Karaikovic; M D Daubs; R W Madsen; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  1997-03-01       Impact factor: 3.468

3.  Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws.

Authors:  I M Mandel; B J Kambach; C A Petersilge; B Johnstone; J U Yoo
Journal:  Spine (Phila Pa 1976)       Date:  2000-06-15       Impact factor: 3.468

Review 4.  Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique.

Authors:  A A Madawi; A T Casey; G A Solanki; G Tuite; R Veres; H A Crockard
Journal:  J Neurosurg       Date:  1997-06       Impact factor: 5.115

5.  Quantitative anatomy of the second cervical vertebra.

Authors:  B J Doherty; M H Heggeness
Journal:  Spine (Phila Pa 1976)       Date:  1995-03-01       Impact factor: 3.468

6.  Screw placement in transoral atlantoaxial plate systems: an anatomical study.

Authors:  F Kandziora; N Schulze-Stahl; C Khodadadyan-Klostermann; R Schröder; T Mittlmeier
Journal:  J Neurosurg       Date:  2001-07       Impact factor: 5.115

Review 7.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Authors:  N M Wright; C Lauryssen
Journal:  J Neurosurg       Date:  1998-04       Impact factor: 5.115

8.  Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study.

Authors:  Francesco Cacciola; Umesh Phalke; Atul Goel
Journal:  Neurol India       Date:  2004-06       Impact factor: 2.117

9.  Morphology of the second cervical vertebra and the posterior projection of the C2 pedicle axis.

Authors:  R Xu; M C Nadaud; N A Ebraheim; R A Yeasting
Journal:  Spine (Phila Pa 1976)       Date:  1995-02-01       Impact factor: 3.468

10.  Fractures of the dens. A multicenter study.

Authors:  C R Clark; A A White
Journal:  J Bone Joint Surg Am       Date:  1985-12       Impact factor: 5.284

View more
  4 in total

1.  Anatomy of the dens and its implications for fracture treatment: an anatomical and radiological study.

Authors:  J Štulík; G Hodasová; M Podhráský; P Nesnídal; P Fojtík; O Naňka
Journal:  Eur Spine J       Date:  2018-10-22       Impact factor: 3.134

2.  Atlas-Free Cervical Spinal Cord Segmentation on Midsagittal T2-Weighted Magnetic Resonance Images.

Authors:  Chun-Chih Liao; Hsien-Wei Ting; Furen Xiao
Journal:  J Healthc Eng       Date:  2017-05-04       Impact factor: 2.682

3.  Odontoid Process and Femur: A Novel Bond in Anatomy.

Authors:  Anastasios Vasilopoulos; Gregory Tsoucalas; Eleni Panagouli; Gregory Trypsianis; Vasilios Thomaidis; Aliki Fiska
Journal:  Cureus       Date:  2020-03-23

4.  A Computed Tomographic Study of Vietnamese C1-C2 Morphology for Atlantoaxial Crew Fixation Techniques.

Authors:  Nguyen Duy Hung; Nguyen Minh Duc; Le Viet Dung; Than Van Sy; Le Thanh Dung; Nguyen Duy Hue
Journal:  J Clin Imaging Sci       Date:  2020-10-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.