Literature DB >> 11453436

Screw placement in transoral atlantoaxial plate systems: an anatomical study.

F Kandziora1, N Schulze-Stahl, C Khodadadyan-Klostermann, R Schröder, T Mittlmeier.   

Abstract

OBJECT: The placement of an anterior atlantoaxial plate after transoral odontoid resection has been described by Harms. Recently, the authors of biomechanical and clinical studies have shown that this procedure, especially in combination with posterior wiring, is a good alternative to established, isolated posterior atlantoaxial fixation techniques. Reports on the anatomy of the atlas and axis primarily focus on the posterior surgical approach. Scarce research regarding the quantitative anatomy of the anterior aspect of C-1 and C-2 has been reported. This study was undertaken to measure relevant dimensions of C-1 and C-2 and their relation to the anterior transoral approach. The aim of the study was to determine "safe zones" for screw placement in anterior atlantoaxial plate fixation.
METHOD: Fifty human dry C-1 and C-2 vertebrae were obtained for direct anatomical, radiographic, and computerized tomography (CT) measurements. Thirty-two linear and four angular parameters were evaluated. All measurements were made using a digital caliper, ruler, or goniometer. Anatomical measurements were correlated with radiographic (anteroposterior, lateral, and craniocaudal) and CT (0.5-mm-slice thickness) measurements of the corresponding vertebrae. Additionally, bone mineral density (BMD) measurements of C-1 and C-2 were obtained in 20 patients. A safe zone for anterior screw placement in an atlas of bilateral trapezoid shape could be characterized. The average medial and lateral height of the trapezoid was 4.1 +/- 1.01 mm (range 1.4-6.7 mm) and 12.9 +/- 1.73 mm (range 8.7-17.4 mm), respectively. The distance between the sagittal plane and the medial and lateral walls of the trapezoid was 10.2 +/- 1.42 mm (range 8.9-12.8 mm) and 23.5 +/- 2.98 mm (range 21.7-30.7 mm), respectively. The average depth of the lateral masses was 22.3 +/- 2.04 mm (range 17.0-26.7 mm) in the sagittal plane. The average BMD in the safe zone of C-1 was 0.89 +/- 0.11 g/cm3 (range 0.75-1.01 g/cm3). Bone mineral density measurements at C-2 revealed a spheroid zone of low density at the basis of the dens (0.68 +/- 0.09 g/cm3). In contrast, high zones of BMD were found near the articular surfaces (C1-2: 0.97 +/- 0.11 g/cm3; C2-3: 0.94 +/- 0.12 g/cm3). The safe zone for anterior axis screw placement was V-shaped, limited cranially by a zone of low bone density and laterally by the vertebral artery groove. Correlations between radiographic and anatomical measurements were generally good (r2 = 0.78-0.95), but they were higher between CT and anatomical measurements (r2 = 0.86-0.99).
CONCLUSIONS: A quantitative understanding of the anterior anatomy of C-1 and C-2 is necessary when considering anterior atlantoaxial plate fixation after transoral odontoid resection. In this study the authors defined safe zones for anterior atlas and axis screw placement. The anterior atlantoaxial plate, as originally described by Harms, only partially respects these safe zones.

Entities:  

Mesh:

Year:  2001        PMID: 11453436     DOI: 10.3171/spi.2001.95.1.0080

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  15 in total

1.  [Surgical procedures to stabilize the upper cervical spine].

Authors:  F Kandziora; K Schnake; R Hoffmann
Journal:  Unfallchirurg       Date:  2010-10       Impact factor: 1.000

2.  Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results.

Authors:  Heiko Koller; Volker Kammermeier; Dietmar Ulbricht; Allan Assuncao; Stefan Karolus; Boris van den Berg; Ulrich Holz
Journal:  Eur Spine J       Date:  2006-04-08       Impact factor: 3.134

3.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

4.  Answer to the Letter to the Editor of R.E.E. Omaña et al. concerning “Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation” by Zeng-Hui Wu et al. Eur Spine J (2014) 23:356-361.

Authors:  Zeng-Hui Wu; Xue-Shi Li; Jun-Jie Xu
Journal:  Eur Spine J       Date:  2014-07-12       Impact factor: 3.134

5.  Detailed anatomy for the transoral approach to the craniovertebral junction: an exposure and safety study.

Authors:  Zhiyun Wang; Hong Xia; Zenghui Wu; Fuzhi Ai; Junjie Xu; Qingshui Yin
Journal:  J Neurol Surg B Skull Base       Date:  2014-02-17

6.  Feasibility and trajectory study of anterior transarticular crossing screw placement for atlantoaxial joint instability: a cadaveric study and description of a novel technique.

Authors:  Wei Ji; Minghui Zheng; Jie Tong; Zhiping Huang; Jianting Chen; Dongbin Qu; Qingan Zhu
Journal:  Eur Spine J       Date:  2015-07-25       Impact factor: 3.134

7.  Anatomy of the dens and its implications for fracture treatment: an anatomical and radiological study.

Authors:  J Štulík; G Hodasová; M Podhráský; P Nesnídal; P Fojtík; O Naňka
Journal:  Eur Spine J       Date:  2018-10-22       Impact factor: 3.134

8.  Morphometric Analysis of Axis and Its Clinical Significance -An Anatomical Study of Indian Human Axis Vertebrae.

Authors:  Mukesh Singla; Prabhat Goel; Mohd Salahuddin Ansari; K S Ravi; Satyam Khare
Journal:  J Clin Diagn Res       Date:  2015-05-01

9.  C2-fractures: part I. Quantitative morphology of the C2 vertebra is a prerequisite for the radiographic assessment of posttraumatic C2-alignment and the investigation of clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Elisabeth Komarek; Michael Fox; Mido Moursy; Wolfgang Hitzl; Herbert Resch
Journal:  Eur Spine J       Date:  2009-02-19       Impact factor: 3.134

10.  Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients.

Authors:  Xueshi Li; Fuzhi Ai; Hong Xia; Zenghui Wu; Xiangyang Ma; Qingshui Yin
Journal:  Eur Spine J       Date:  2014-05-17       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.