Literature DB >> 10851104

Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws.

I M Mandel1, B J Kambach, C A Petersilge, B Johnstone, J U Yoo.   

Abstract

STUDY
DESIGN: This study examines the C2 vertebrae using both direct anatomic and computed tomographic measurements.
OBJECTIVE: To define the relation of the C2 vertebrae bony elements to the vertebral artery and the spinal canal, to determine individuals at risk for vertebral artery injury during C1-C2 transarticular screw placement. SUMMARY OF BACKGROUND DATA: Recent literature assessing the safety of upper cervical spine transarticular screws has concentrated on technique, including the optimal point of entry and path projection of the screw. The actual dimensions of the C2 isthmus of the pars interarticularis has not been examined in a large number of specimens.
METHODS: C2 isthmus width and height measurements were made on 205 human cadaveric C2 vertebrae. Vertebrae predicted to be at risk for vertebral arterial injury were imaged by computed tomography.
RESULTS: There were 102 female and 103 male specimens with mean isthmus widths of 8.2 +/- 1.5 mm and 7.2 +/- 1.3 mm, respectively. Five specimens (2.4%) had an isthmus width less than 5 mm. The mean isthmus heights were 8.6 +/- 2.0 mm and 6.9 +/- 1.5 mm for male and female specimens, respectively. In twenty-four specimens (11.7%), one or both isthmi had a height of less than 5 mm. Six of these specimens were male and 18 were female. The right C2 isthmus was generally smaller than the left. Computed tomographic measurements closely approximated those of the actual dimensions of the isthmi.
CONCLUSIONS: Placing a 3.5 mm screw in a patient with narrow C2 isthmus dimensions (smaller than 5 mm in either the height or width) is technically difficult. Because of narrow C2 isthmus width and/or height, approximately 10% of patients may be at risk for a vertebral artery injury with placement of C1-C2 transarticular screws.

Entities:  

Mesh:

Year:  2000        PMID: 10851104     DOI: 10.1097/00007632-200006150-00014

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  42 in total

1.  Catheter-directed percutaneous transpedicular C2/C3 vertebroplasty in a patient with fibrous dysplasia using seldinger technique.

Authors:  G Christoforidis; D Dang; J Gabriel
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

2.  Atlantoaxial fusion using anterior transarticular screw fixation of C1-C2: technical innovation and biomechanical study.

Authors:  Milan K Sen; Thomas Steffen; Lorne Beckman; Anthony Tsantrizos; Rudolph Reindl; Max Aebi
Journal:  Eur Spine J       Date:  2005-01-25       Impact factor: 3.134

3.  The borders of the odontoid process of C2 in adults and in children including the estimation of odontoid/body ratio.

Authors:  Cengiz Cokluk; Keramettin Aydin; Cemil Rakunt; Omer Iyigun; Arif Onder
Journal:  Eur Spine J       Date:  2005-06-21       Impact factor: 3.134

4.  A clinical morphologic study of the C2 pedicle and isthmus.

Authors:  Feng Yuan; Hui-Lin Yang; Kai-Jin Guo; Jiang-Shan Li; Kai Xu; Zhi-Ming Zhang; Tian-Si Tang
Journal:  Eur Spine J       Date:  2012-08-14       Impact factor: 3.134

5.  Targeting a safe entry point for c2 pedicle screw fixation in patients with atlantoaxial instability.

Authors:  Hyoung-Joon Chun; Koang Hum Bak
Journal:  J Korean Neurosurg Soc       Date:  2011-06-30

6.  Posterior atalntoaxial fusion with c1 lateral mass screw and c2 pedicle screw supplemented with miniplate fixation for interlaminar fusion : a preliminary report.

Authors:  Sang-Mok Yoon; Jin-Wook Baek; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2012-08-31

7.  Multiplanar reconstructions of helical computed tomography in planning of atlanto-axial transarticular fixation.

Authors:  M H Nogueira-Barbosa; H L A Defino
Journal:  Eur Spine J       Date:  2005-03-08       Impact factor: 3.134

Review 8.  Fusions at the craniovertebral junction.

Authors:  Raheel Ahmed; Vincent C Traynelis; Arnold H Menezes
Journal:  Childs Nerv Syst       Date:  2008-04-04       Impact factor: 1.475

9.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

10.  Morphometric Analysis of Axis and Its Clinical Significance -An Anatomical Study of Indian Human Axis Vertebrae.

Authors:  Mukesh Singla; Prabhat Goel; Mohd Salahuddin Ansari; K S Ravi; Satyam Khare
Journal:  J Clin Diagn Res       Date:  2015-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.