Literature DB >> 26154301

Assessment of clinical occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape.

Paddy Gilligan1, J Lynch2, H Eder3, S Maguire1, E Fox1, B Doyle1, I Casserly1, H McCann1, D Foley1.   

Abstract

OBJECTIVES: To assess the occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape.
BACKGROUND: Transradial access for catheterization has been shown to increase occupational radiation dose. Current shielding techniques are primarily based on the femoral access. This article looks at the clinical occupational combined dose reduction effect of a commercially available shield and drape which is specific to access type.
METHODS: The evaluation took place in a busy interventional cardiology laboratory, with a single plane 30×40 cm flat panel detector (Siemens Artis Zee, Germany). Radiation exposure to staff was measured using electronic personal dosimeters (Unfors RaysafeAB, Sweden) placed at the collar. Patient radiation exposure was assessed using screening time and dose area product per case. Both staff and patient radiation exposure were monitored for a number of case types and operators before, during, and after deployment of the new shield and drapes.
RESULTS: The cardiologists' overall median collar badge reading per case reduced from 15.4 μSv per case without the shield/drape combination to 7.3 μSv per case with the shield drape combination in situ (P<0.001). The radiographers badge reading was reduced from 4.2 μSv per case without to 2.5 μSv per case with the shield drape combination in situ (P<0.001). There was no statistical difference in the cardiac technician's badge reading. Patient's dose area product was not significantly affected by the placement of the shield and drape combination.
CONCLUSIONS: The shield/drape combination can significantly reduce operator exposure in a cardiac catheterization laboratory.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  CATB-catheterization; CATH-catheterization; IAF-imaging; RADI-radiation; angiographic/fluoroscopic; brachial/radial/ulnar; diagnostic; physics/dosimetry

Mesh:

Substances:

Year:  2015        PMID: 26154301     DOI: 10.1002/ccd.26009

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Towards Robot-Assisted Echocardiographic Monitoring in Catheterization Laboratories : Usability-Centered Manipulator for Transesophageal Echocardiography.

Authors:  Christina Pahl; Henning Ebelt; Mostafa Sayahkarajy; Eko Supriyanto; Amiliana Soesanto
Journal:  J Med Syst       Date:  2017-08-15       Impact factor: 4.460

2.  Selective anti-scatter grid removal during coronary angiography and PCI: a simple and safe technique for radiation reduction.

Authors:  James R Roy; Philip Sun; Glenn Ison; Ananth M Prasan; Tom Ford; Andrew Hopkins; David R Ramsay; James C Weaver
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-24       Impact factor: 2.357

Review 3.  Occupational radiation exposure to nursing staff during cardiovascular fluoroscopic procedures: A review of the literature.

Authors:  Kelly Wilson-Stewart; Madeleine Shanahan; Davide Fontanarosa; Rob Davidson
Journal:  J Appl Clin Med Phys       Date:  2018-10-08       Impact factor: 2.102