Literature DB >> 26153387

Improved spoiling efficiency in dynamic RF-spoiled imaging by ghost phase modulation and temporal filtering.

Jon-Fredrik Nielsen1, Douglas C Noll1.   

Abstract

PURPOSE: Radiofrequency-spoiled steady-state sequences offer rapid data acquisition with T1- or T2*-weighting. The spoiler gradients in these sequences must be large enough to suppress ghost artifacts, and are chosen empirically. However, certain factors such as the need to minimize gradient first moments or acoustic noise can limit the spoiler size and, hence, the ability to suppress ghosts. We present an acquisition and preprocessing strategy for improved spoiling efficiency in conventional and echo-shifted dynamic radiofrequency-spoiled 3D imaging. THEORY AND METHODS: By requiring each time-frame in a dynamic imaging sequence to contain a particular (restricted) number of total radiofrequency shots, the ghost signal can be made to alternate in sign every other frame. The ghost is then suppressed by Fourier transforming along the temporal dimension, and removing the Nyquist frequency in preprocessing (similar to UNFOLD). The method works for both Cartesian and non-Cartesian imaging.
RESULTS: We demonstrate improved ghost suppression with the proposed approach, for both conventional and echo-shifted spoiled gradient echo imaging in stationary phantoms and in vivo. Cartesian echo-shifted spoiled gradient echo imaging produces two ghosts shifted in opposite directions, both of which are suppressed with our method.
CONCLUSION: For a given spoiler gradient area, the proposed approach substantially suppresses the ghost signal in both conventional and echo-shifted dynamic radiofrequency-spoiled imaging. Magn Reson Med 75:2388-2393, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  RF-spoiling; dynamic T1-weighted imaging; ghost artifacts; gradient echo

Mesh:

Year:  2015        PMID: 26153387      PMCID: PMC4704999          DOI: 10.1002/mrm.25843

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

3.  New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.

Authors:  Vincent Denolin; Céline Azizieh; Thierry Metens
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

4.  Steady state of echo-shifted sequences with radiofrequency phase cycling.

Authors:  Carl Ganter
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

5.  Spoiling of transverse magnetization in steady-state sequences.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1991-10       Impact factor: 4.668

6.  Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI.

Authors:  Matthew J Middione; Holden H Wu; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2013-12-17       Impact factor: 4.668

7.  Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

Authors:  Jochen Leupold; Jürgen Hennig; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

8.  Increasing spoiling efficiency in RF-spoiled gradient echo sequences by averaging of RF phase-cycle-adapted k-spaces.

Authors:  Jochen Leupold; Jürgen Hennig
Journal:  Magn Reson Med       Date:  2011-03-09       Impact factor: 4.668

Review 9.  The PRESTO technique for fMRI.

Authors:  P van Gelderen; J H Duyn; N F Ramsey; G Liu; C T W Moonen
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

10.  A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO).

Authors:  G Liu; G Sobering; J Duyn; C T Moonen
Journal:  Magn Reson Med       Date:  1993-12       Impact factor: 4.668

  10 in total
  3 in total

1.  TOPPE: A framework for rapid prototyping of MR pulse sequences.

Authors:  Jon-Fredrik Nielsen; Douglas C Noll
Journal:  Magn Reson Med       Date:  2017-11-02       Impact factor: 4.668

2.  Imperfect spoiling in variable flip angle T1 mapping at 7T: Quantifying and minimizing impact.

Authors:  Nadège Corbin; Martina F Callaghan
Journal:  Magn Reson Med       Date:  2021-03-01       Impact factor: 3.737

3.  Hexagonal gradient scheme with RF spoiling improves spoiling performance for high-flip-angle fast gradient echo imaging.

Authors:  Aaron T Hess; Matthew D Robson
Journal:  Magn Reson Med       Date:  2016-04-01       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.