Literature DB >> 16155898

New insights into the mechanisms of signal formation in RF-spoiled gradient echo sequences.

Vincent Denolin1, Céline Azizieh, Thierry Metens.   

Abstract

RF spoiling is a well established method to produce T(1)-weighted images with short repetition-time gradient-echo sequences, by eliminating coherent transverse magnetization with appropriate RF phase modulation. This paper presents 2 novel approaches to describe signal formation in such sequences. Both methods rely on the formulation of RF spoiling as a linear increase of the precession angle between RF pulses, which is an alternative to the commonly used quadratic pulse phase scheme. The first technique demonstrates that a steady state signal can be obtained by integrating over all precession angles within the voxel, in spite of the lack of a genuine steady-state for separate isochromats. This clear mathematical framework allows a straightforward incorporation of off-resonance effects and detector phase settings. Moreover, it naturally introduces the need for a large net gradient area per repetition interval. In the second step, a modified partition method including RF spoiling is developed to obtain explicit expressions for all signal components. This provides a physical interpretation of the deviations from ideal spoiling behavior in FLASH and echo-shifted sequences. The results of the partition method in the small flip angle regime are compared with numerical simulations based on a Fourier decomposition of magnetization states. Measurements performed with in vitro solutions were in good agreement with numerical simulations at short relaxation times (T(1)/TR = 32 and T(2)/TR = 4); larger deviations occurred at long relaxation times (T(1)/TR = 114 and T(2)/TR = 82). Copyright 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16155898     DOI: 10.1002/mrm.20652

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging.

Authors:  Yuhong Peng; Chao Zou; Yangzi Qiao; Changjun Tie; Qian Wan; Rui Jiang; Chuanli Cheng; Dong Liang; Hairong Zheng; Faqi Li; Xin Liu
Journal:  MAGMA       Date:  2018-06-14       Impact factor: 2.310

2.  [Spin echo and gradient echo : Methodological duo of MRI].

Authors:  J Leupold; J Neubauer; M Bock
Journal:  Radiologe       Date:  2018-08       Impact factor: 0.635

Review 3.  Quantitative relaxometry of the brain.

Authors:  Sean C L Deoni
Journal:  Top Magn Reson Imaging       Date:  2010-04

4.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

5.  MRI and MR angiography evaluation of pulsatile tinnitus: A focused, physiology-based protocol.

Authors:  Daniel D Cummins; Michael T Caton; Vinil Shah; Karl Meisel; Christine Glastonbury; Matthew R Amans
Journal:  J Neuroimaging       Date:  2021-12-15       Impact factor: 2.486

6.  Improved spoiling efficiency in dynamic RF-spoiled imaging by ghost phase modulation and temporal filtering.

Authors:  Jon-Fredrik Nielsen; Douglas C Noll
Journal:  Magn Reson Med       Date:  2015-07-07       Impact factor: 4.668

7.  Optimizing trajectory ordering for fast radial ultra-short TE (UTE) acquisitions.

Authors:  Xucheng Zhu; Fei Tan; Kevin Johnson; Peder Larson
Journal:  J Magn Reson       Date:  2021-04-02       Impact factor: 2.734

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.