Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†.

J Mallat1, M Meddour2, E Durville2, M Lemyze2, F Pepy2, J Temime2, N Vangrunderbeeck2, L Tronchon2, D Thevenin2, B Tavernier3.   

Abstract

BACKGROUND: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
METHODS: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
RESULTS: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
CONCLUSIONS: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure

Mesh:

Year:  2015        PMID: 26152341     DOI: 10.1093/bja/aev222

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  18 in total

Review 1.  Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades.

Authors:  Antonio Messina; Lorenzo Calabrò; Luca Pugliese; Aulona Lulja; Alexandra Sopuch; Daniela Rosalba; Emanuela Morenghi; Glenn Hernandez; Xavier Monnet; Maurizio Cecconi
Journal:  Crit Care       Date:  2022-06-21       Impact factor: 19.334

2.  Validation of the UNESP-Botucatu pig composite acute pain scale (UPAPS).

Authors:  Stelio Pacca Loureiro Luna; Ana Lucélia de Araújo; Pedro Isidro da Nóbrega Neto; Juliana Tabarelli Brondani; Flávia Augusta de Oliveira; Liliane Marinho Dos Santos Azerêdo; Felipe Garcia Telles; Pedro Henrique Esteves Trindade
Journal:  PLoS One       Date:  2020-06-01       Impact factor: 3.240

Review 3.  Prediction of fluid responsiveness in ventilated patients.

Authors:  Mathieu Jozwiak; Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2018-09

Review 4.  Context-sensitive fluid therapy in critical illness.

Authors:  Tsuneo Tatara
Journal:  J Intensive Care       Date:  2016-03-15

Review 5.  What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis.

Authors:  Laura Toscani; Hollmann D Aya; Dimitra Antonakaki; Davide Bastoni; Ximena Watson; Nish Arulkumaran; Andrew Rhodes; Maurizio Cecconi
Journal:  Crit Care       Date:  2017-08-04       Impact factor: 9.097

Review 6.  Acute Right Ventricular Dysfunction in Intensive Care Unit.

Authors:  Juan C Grignola; Enric Domingo
Journal:  Biomed Res Int       Date:  2017-10-19       Impact factor: 3.411

Review 7.  Prediction of fluid responsiveness in spontaneously breathing patients.

Authors:  Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2020-06

8.  Evaluation of least significant changes of pulse contour analysis-derived parameters.

Authors:  Hugues de Courson; Loic Ferrer; Grégoire Cane; Eric Verchère; Musa Sesay; Karine Nouette-Gaulain; Matthieu Biais
Journal:  Ann Intensive Care       Date:  2019-10-11       Impact factor: 6.925

9.  Application strategy of PiCCO in septic shock patients.

Authors:  Xiaoyun Liu; Wenli Ji; Jifeng Wang; Tao Pan
Journal:  Exp Ther Med       Date:  2016-01-29       Impact factor: 2.447

Review 10.  Fluid responsiveness in acute circulatory failure.

Authors:  Ahmed Hasanin
Journal:  J Intensive Care       Date:  2015-11-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.