Literature DB >> 26138549

The clinical effectiveness and cost-effectiveness of point-of-care tests (CoaguChek system, INRatio2 PT/INR monitor and ProTime Microcoagulation system) for the self-monitoring of the coagulation status of people receiving long-term vitamin K antagonist therapy, compared with standard UK practice: systematic review and economic evaluation.

Pawana Sharma1, Graham Scotland1,2, Moira Cruickshank1, Emma Tassie2, Cynthia Fraser1, Chris Burton3, Bernard Croal4, Craig R Ramsay1, Miriam Brazzelli1.   

Abstract

BACKGROUND: Self-monitoring (self-testing and self-management) could be a valid option for oral anticoagulation therapy monitoring in the NHS, but current evidence on its clinical effectiveness or cost-effectiveness is limited.
OBJECTIVES: We investigated the clinical effectiveness and cost-effectiveness of point-of-care coagulometers for the self-monitoring of coagulation status in people receiving long-term vitamin K antagonist therapy, compared with standard clinic monitoring. DATA SOURCES: We searched major electronic databases (e.g. MEDLINE, MEDLINE In Process & Other Non-Indexed Citations, EMBASE, Bioscience Information Service, Science Citation Index and Cochrane Central Register of Controlled Trials) from 2007 to May 2013. Reports published before 2007 were identified from the existing Cochrane review (major databases searched from inception to 2007). The economic model parameters were derived from the clinical effectiveness review, other relevant reviews, routine sources of cost data and clinical experts' advice. REVIEW
METHODS: We assessed randomised controlled trials (RCTs) evaluating self-monitoring in people with atrial fibrillation or heart valve disease requiring long-term anticoagulation therapy. CoaguChek(®) XS and S models (Roche Diagnostics, Basel, Switzerland), INRatio2(®) PT/INR monitor (Alere Inc., San Diego, CA USA), and ProTime Microcoagulation system(®) (International Technidyne Corporation, Nexus Dx, Edison, NJ, USA) coagulometers were compared with standard monitoring. Where possible, we combined data from included trials using standard inverse variance methods. Risk of bias assessment was performed using the Cochrane risk of bias tool. A de novo economic model was developed to assess the cost-effectiveness over a 10-year period.
RESULTS: We identified 26 RCTs (published in 45 papers) with a total of 8763 participants. CoaguChek was used in 85% of the trials. Primary analyses were based on data from 21 out of 26 trials. Only four trials were at low risk of bias. Major clinical events: self-monitoring was significantly better than standard monitoring in preventing thromboembolic events [relative risk (RR) 0.58, 95% confidence interval (CI) 0.40 to 0.84; p = 0.004]. In people with artificial heart valves (AHVs), self-monitoring almost halved the risk of thromboembolic events (RR 0.56, 95% CI 0.38 to 0.82; p = 0.003) and all-cause mortality (RR 0.54, 95% CI 0.32 to 0.92; p = 0.02). There was greater reduction in thromboembolic events and all-cause mortality through self-management but not through self-testing. Intermediate outcomes: self-testing, but not self-management, showed a modest but significantly higher percentage of time in therapeutic range, compared with standard care (weighted mean difference 4.44, 95% CI 1.71 to 7.18; p = 0.02). Patient-reported outcomes: improvements in patients' quality of life related to self-monitoring were observed in six out of nine trials. High preference rates were reported for self-monitoring (77% to 98% in four trials). Net health and social care costs over 10 years were £7295 (self-monitoring with INRatio2); £7324 (standard care monitoring); £7333 (self-monitoring with CoaguChek XS) and £8609 (self-monitoring with ProTime). The estimated quality-adjusted life-year (QALY) gain associated with self-monitoring was 0.03. Self-monitoring with INRatio2 or CoaguChek XS was found to have ≈ 80% chance of being cost-effective, compared with standard monitoring at a willingness-to-pay threshold of £20,000 per QALY gained.
CONCLUSIONS: Compared with standard monitoring, self-monitoring appears to be safe and effective, especially for people with AHVs. Self-monitoring, and in particular self-management, of anticoagulation status appeared cost-effective when pooled estimates of clinical effectiveness were applied. However, if self-monitoring does not result in significant reductions in thromboembolic events, it is unlikely to be cost-effective, based on a comparison of annual monitoring costs alone. Trials investigating the longer-term outcomes of self-management are needed, as well as direct comparisons of the various point-of-care coagulometers. STUDY REGISTRATION: This study is registered as PROSPERO CRD42013004944. FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26138549      PMCID: PMC4780913          DOI: 10.3310/hta19480

Source DB:  PubMed          Journal:  Health Technol Assess        ISSN: 1366-5278            Impact factor:   4.014


  10 in total

1.  Cost-effectiveness analysis of patient self-testing therapy of oral anticoagulation.

Authors:  Sutat Kantito; Surasak Saokaew; Sukit Yamwong; Prin Vathesatogkit; Wisuit Katekao; Piyamitr Sritara; Nathorn Chaiyakunapruk
Journal:  J Thromb Thrombolysis       Date:  2018-02       Impact factor: 2.300

2.  Sources of unsafe primary care for older adults: a mixed-methods analysis of patient safety incident reports.

Authors:  Alison Cooper; Adrian Edwards; Huw Williams; Huw P Evans; Anthony Avery; Peter Hibbert; Meredith Makeham; Aziz Sheikh; Liam J Donaldson; Andrew Carson-Stevens
Journal:  Age Ageing       Date:  2017-09-01       Impact factor: 10.668

3.  Follow-up and management of valvular heart disease patients with prosthetic valve: a clinical practice guideline for Indian scenario.

Authors:  Devendra Saksena; Yugal K Mishra; S Muralidharan; Vivek Kanhere; Pankaj Srivastava; C P Srivastava
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-01-28

4.  American Society of Hematology 2018 guidelines for management of venous thromboembolism: optimal management of anticoagulation therapy.

Authors:  Daniel M Witt; Robby Nieuwlaat; Nathan P Clark; Jack Ansell; Anne Holbrook; Jane Skov; Nadine Shehab; Juliet Mock; Tarra Myers; Francesco Dentali; Mark A Crowther; Arnav Agarwal; Meha Bhatt; Rasha Khatib; John J Riva; Yuan Zhang; Gordon Guyatt
Journal:  Blood Adv       Date:  2018-11-27

Review 5.  Self-monitoring and self-management of oral anticoagulation.

Authors:  Carl J Heneghan; Josep M Garcia-Alamino; Elizabeth A Spencer; Alison M Ward; Rafael Perera; Clare Bankhead; Pablo Alonso-Coello; David Fitzmaurice; Kamal R Mahtani; Igho J Onakpoya
Journal:  Cochrane Database Syst Rev       Date:  2016-07-05

6.  Home management of INR in the public health system: feasibility of self-management of oral anticoagulation and long-term performance of individual POC devices in determining INR.

Authors:  Sabrina da Silva Saraiva; Fernanda Andrade Orsi; Marcos Pereira Santos; Tania Machado; Silmara Montalvão; Carolina Costa-Lima; Erich Vinícius de Paula; Marina Pereira Colella; Joyce Annichino-Bizzacchi
Journal:  J Thromb Thrombolysis       Date:  2016-07       Impact factor: 2.300

7.  Clinical evaluation of whole blood prothrombin time (PT) and international normalized ratio (INR) using a Laser Speckle Rheology sensor.

Authors:  Markandey M Tripathi; Satoru Egawa; Alexandra G Wirth; Diane M Tshikudi; Elizabeth M Van Cott; Seemantini K Nadkarni
Journal:  Sci Rep       Date:  2017-08-23       Impact factor: 4.379

8.  The Role of Measurement Uncertainty in Health Technology Assessments (HTAs) of In Vitro Tests.

Authors:  Alison F Smith; Mike Messenger; Peter Hall; Claire Hulme
Journal:  Pharmacoeconomics       Date:  2018-07       Impact factor: 4.981

9.  Optimising clinical effectiveness and quality along the atrial fibrillation anticoagulation pathway: an economic analysis.

Authors:  Eoin Moloney; Dawn Craig; Nikki Holdsworth; Joanne Smithson
Journal:  BMC Health Serv Res       Date:  2019-12-28       Impact factor: 2.655

10.  Is a novel diagnostic pathway for cardiology outpatient clinics in Singapore lower cost than existing practice: a cost modelling study.

Authors:  Huang Weiting; Gaya Karthik; Terrance Chua; Nicholas Graves
Journal:  BMJ Open       Date:  2022-02-01       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.