Literature DB >> 26078511

Percutaneous Trigger Release in Non-Triggering Digits: Infiltration of Normal Saline into Tendon Substance to Induce Triggering.

Winston Yoon Chong Chew1, Sechachalam Sreedharan1.   

Abstract

Percutaneous trigger release is recognized as an effective minimally invasive procedure with a low complication rate. One prerequisite for percutaneous trigger release is a trigger of Quinnell Type II or higher; that is, a digit that is actively triggering. We describe an additional step in percutaneous trigger release, which enables the surgeon to perform the procedure in digits that are not actively triggering at the point of surgery. This step involves the infiltration of normal saline into the tendon substance distal to the A1 pulley in order to induce triggering.

Keywords:  Needle; Normal saline infiltration; Percutaneous trigger release; Pulley release

Year:  2015        PMID: 26078511      PMCID: PMC4461638          DOI: 10.1007/s12593-015-0170-x

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  7 in total

1.  Trigger finger release with hand surface landmark ratios: an anatomic and clinical study.

Authors:  B J Wilhelmi; N Snyder; J E Verbesey; P A Ganchi; W P Lee
Journal:  Plast Reconstr Surg       Date:  2001-09-15       Impact factor: 4.730

Review 2.  Percutaneous release of trigger fingers.

Authors:  Edson Sasahara Sato; João Baptista Gomes dos Santos; João Carlos Belloti; Walter Manna Albertoni; Flavio Faloppa
Journal:  Hand Clin       Date:  2013-11-09       Impact factor: 1.907

3.  The safety of percutaneous trigger finger release.

Authors:  J Mark Schramm; Minhthy Nguyen; Montri D Wongworawat
Journal:  Hand (N Y)       Date:  2007-09-14

4.  Open versus percutaneous release of the A1-pulley for stenosing tendovaginitis: a prospective randomized trial.

Authors:  Ulf Dierks; Reimer Hoffmann; Marcel F Meek
Journal:  Tech Hand Up Extrem Surg       Date:  2008-09

5.  Safety and efficacy of percutaneous trigger finger release.

Authors:  D F Pope; S W Wolfe
Journal:  J Hand Surg Am       Date:  1995-03       Impact factor: 2.230

6.  Percutaneous A1 pulley release: a cadaveric study.

Authors:  G I Bain; J Turnbull; M N Charles; J H Roth; R S Richards
Journal:  J Hand Surg Am       Date:  1995-09       Impact factor: 2.230

7.  Percutaneous release of the A1 pulley: a cadaver study.

Authors:  Rohan Habbu; Matthew D Putnam; Julie E Adams
Journal:  J Hand Surg Am       Date:  2012-11       Impact factor: 2.230

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.