Literature DB >> 11547146

Trigger finger release with hand surface landmark ratios: an anatomic and clinical study.

B J Wilhelmi1, N Snyder, J E Verbesey, P A Ganchi, W P Lee.   

Abstract

The purpose of this study was to identify surface landmark ratios to locate the A1 pulley and clarify the controversy of differing anatomic descriptions of the A1, C0, and A2 pulleys. Minimally invasive and percutaneous approaches to A1 pulley release may be facilitated with surface landmark ratios, which identify and predict the proximal and distal margins of the A1 pulley. Two-hundred fifty-sixty fingers were dissected in 64 preserved cadaver hands. Measurements of A1 pulley lengths and pulley margins in relation to surface landmarks were obtained. We found that the distance from the palmar digital crease to the proximal interphalangeal crease (mean, 2.42 +/- 0.03 cm) corresponds to the distance of the proximal edge of the A1 pulley from the palmar digital crease (mean, 2.45 +/- 0.03 cm). The mean absolute difference between these two measured distances in each finger was 0.13 cm, with a 95 percent confidence interval of 0.11 to 0.14 cm. Thus, the distance between the palmar digital crease and the proximal interphalangeal crease can be used to predict the distance between the palmar digital crease and the A1 pulley proximal edge with reasonable accuracy. A1 pulley length averaged 0.98 +/- 0.02 cm for the small finger and 1.17 +/- 0.02 cm for the index, middle, and ring fingers. The length of the A1 pulley was significantly shorter (p < 0.001) for the small finger than for the index, middle, and ring fingers. Additionally, a cruciate (C0) pulley was consistently located between the A1 and A2 pulleys, an average of 0.46 cm proximal to the palmar digital crease, which can serve as guide for concluding the release of the A1 pulley. Clinically, hand surface landmark ratios were used to release 32 trigger fingers with a minimally invasive technique, without a complication during 4- to 30-week follow-up. We conclude that hand surface landmark ratios can serve to locate the proximal A1 pulley edge, thus facilitating complete trigger finger release by either open or minimally invasive techniques. Additionally, our study clarifies the discrepancy of prior smaller reports of the pulley system anatomy regarding the existence of the C0 pulley between the A1 and A2 pulleys. The cruciate fibers of this C0 pulley can serve as the distal boundary for release of trigger finger.

Mesh:

Year:  2001        PMID: 11547146     DOI: 10.1097/00006534-200109150-00014

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  11 in total

Review 1.  Management and referral for trigger finger/thumb.

Authors:  Sohail Akhtar; Mary J Bradley; David N Quinton; Frank D Burke
Journal:  BMJ       Date:  2005-07-02

2.  Percutaneous Trigger Release in Non-Triggering Digits: Infiltration of Normal Saline into Tendon Substance to Induce Triggering.

Authors:  Winston Yoon Chong Chew; Sechachalam Sreedharan
Journal:  J Hand Microsurg       Date:  2015-01-10

3.  The Relationship Between the Intercrease Line and the A1 Digital Pulley: A Cadaveric Study.

Authors:  Colyn J Watkins; Nikola Zivaljevic; Kyle R Eberlin; Michael Rivlin; Chaitanya S Mudgal
Journal:  Hand (N Y)       Date:  2016-07-28

4.  Transverse anatomic landmarks for the A1 pulley of the thumb.

Authors:  Ron Hazani; Josh Elston; Bradon J Wilhelmi
Journal:  Hand (N Y)       Date:  2011-07-02

5.  The little finger ulnar palmar digital artery perforator flap: anatomical basis.

Authors:  Francesca Toia; Marcella Marchese; Barbara Boniforti; Pierluigi Tos; Luca Delcroix
Journal:  Surg Radiol Anat       Date:  2013-02-27       Impact factor: 1.246

Review 6.  Study to outline the efficacy and illustrate techniques for steroid injection for trigger finger and thumb.

Authors:  S Akhtar; F D Burke
Journal:  Postgrad Med J       Date:  2006-11       Impact factor: 2.401

Review 7.  Surgery for trigger finger.

Authors:  Haroldo Junior Fiorini; Marcel Jun Tamaoki; Mário Lenza; Joao Baptista Gomes Dos Santos; Flávio Faloppa; Joao Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2018-02-20

8.  Assessment of the distal extent of the A1 pulley release: a new technique.

Authors:  Ron Hazani; Nitin J Engineer; Linda L Zeineh; Bradon J Wilhelmi
Journal:  Eplasty       Date:  2008-08-22

9.  The Safety of Percutaneous Trigger Digit Release Increased by Neurovascular Displacement with Local Hydraulic Dilatation: An Anatomical and Clinical Study.

Authors:  Honggang Wang; Ping Wang; Obioma Amajoyi; Clark J Chen; Gary Y Chen
Journal:  Med Sci Monit       Date:  2017-10-22

10.  Location and Extent of A1, A2 Release and Its Impact on Tendon Subluxation and Bowstringing-A Cadaveric Study.

Authors:  Laxminarayan Bhandari; Alireza Hamidian Jahromi; Aden Gunnar Miller; Huey Tien
Journal:  Indian J Plast Surg       Date:  2019-12-26
View more