Literature DB >> 8522744

Percutaneous A1 pulley release: a cadaveric study.

G I Bain1, J Turnbull, M N Charles, J H Roth, R S Richards.   

Abstract

Percutaneous A1 pulley release was performed on 17 fresh-frozen cadaveric hands with a 14-gauge angiocath needle. Each hand was then explored to assess the adequacy of release and the degree of injury to adjacent structures. Complete release of the A1 pulley was obtained in 45 of the 66 fingers and in 10 of the 17 thumbs. Significant injury to the flexor tendons was observed in two digits. All tendon injuries occurred along the line of the fibers. There were no digital nerve injuries. The release was within 2 mm of a thumb digital nerve in seven hands and the little finger ulnar digital nerve in two. In the thumb, the close proximity of the digital nerves makes percutaneous trigger digit release potentially hazardous. With the little finger held in abduction the risk of digital nerve injury or inadequate release is reduced. Percutaneous trigger finger release can be safely performed in the index, long, and ring fingers.

Entities:  

Mesh:

Year:  1995        PMID: 8522744     DOI: 10.1016/S0363-5023(05)80430-7

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  16 in total

Review 1.  Management and referral for trigger finger/thumb.

Authors:  Sohail Akhtar; Mary J Bradley; David N Quinton; Frank D Burke
Journal:  BMJ       Date:  2005-07-02

2.  Ultrasound-guided percutaneous release of the annular pulley in trigger digit.

Authors:  Gajan Rajeswaran; Justin C Lee; Rupert Eckersley; Effie Katsarma; Jeremiah C Healy
Journal:  Eur Radiol       Date:  2009-04-28       Impact factor: 5.315

3.  Ultrasound-assisted percutaneous trigger finger release: is it safe?

Authors:  Karina L Paulius; Pirko Maguina
Journal:  Hand (N Y)       Date:  2008-10-02

4.  The safety of percutaneous trigger finger release.

Authors:  J Mark Schramm; Minhthy Nguyen; Montri D Wongworawat
Journal:  Hand (N Y)       Date:  2007-09-14

5.  Percutaneous Trigger Release in Non-Triggering Digits: Infiltration of Normal Saline into Tendon Substance to Induce Triggering.

Authors:  Winston Yoon Chong Chew; Sechachalam Sreedharan
Journal:  J Hand Microsurg       Date:  2015-01-10

6.  The Relationship Between the Intercrease Line and the A1 Digital Pulley: A Cadaveric Study.

Authors:  Colyn J Watkins; Nikola Zivaljevic; Kyle R Eberlin; Michael Rivlin; Chaitanya S Mudgal
Journal:  Hand (N Y)       Date:  2016-07-28

7.  Assessment of clinical outcome of percutaneous needle quadriceps tenotomy in the treatment of congenital knee dislocation.

Authors:  Sandeep Patwardhan; Kunal Shah; Ashok Shyam; Parag Sancheti
Journal:  Int Orthop       Date:  2015-06-20       Impact factor: 3.075

8.  Percutaneous release of the trigger thumb: is it safe, cheap and effective?

Authors:  Oguz Cebesoy; Gunhan Karakurum; Kamil Cagri Kose; Enver Taner Baltaci; Mustafa Isik
Journal:  Int Orthop       Date:  2006-07-18       Impact factor: 3.075

Review 9.  Study to outline the efficacy and illustrate techniques for steroid injection for trigger finger and thumb.

Authors:  S Akhtar; F D Burke
Journal:  Postgrad Med J       Date:  2006-11       Impact factor: 2.401

10.  Outcome of percutaneous trigger finger release technique using a 20-gauge hypodermic needle.

Authors:  Atul Panghate; Sameer Panchal; Akil Prabhakar; Abhinav Jogani
Journal:  J Clin Orthop Trauma       Date:  2020-10-25
View more