BACKGROUND: Pulmonary embolism (PE) is a potentially life-threatening condition. Although computed tomography pulmonary angiography (CTPA) is the reference standard for diagnosis, its early diagnosis remains a challenge, and the concerns about the radiation exposures further limit the general use of CTPA. The primary aim of this meta-analysis was to evaluate the overall diagnostic accuracy of transthoracic lung ultrasound (TLS) in the diagnosis of PE.Entities:
Mesh:
Year: 2015 PMID: 26076021 PMCID: PMC4468196 DOI: 10.1371/journal.pone.0129909
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Characteristics of Eligible Studies-1.
| Author | Year | Patients ( | Male (%) | Consecutive | Age | TP | FP | FN | TN | Ultrasonography technology |
|---|---|---|---|---|---|---|---|---|---|---|
| Peiman [ | 2013 | 357 | 47 |
| 71 (14) | 67 | 10 | 43 | 237 | 4–8 MHz liner probe /3.5–5 MHz curved probe |
| Comert [ | 2013 | 50 | 54 |
| 54.1 (17.9) | 27 | 8 | 3 | 12 | 3.5 Mhz convex probe |
| Pfeil[ | 2010 | 33 | 52 |
| 65.4 (19–92) | 7 | 7 | 3 | 16 | 5/3.5 MHz convex probe |
| Mathis[ | 2005 | 352 | 47 |
| 64 (18–98) | 144 | 8 | 50 | 150 | 3.5–6 MHz curved array /sector scanner |
| Reissing[ | 2004 | 62 | 60 |
| 62.2 (24–88) | 30 | 2 | 9 | 21 | 5 / 3.5 MHz convex scanner |
| Mohn[ | 2003 | 74 | 57 |
| 66 (17) | 22 | 10 | 9 | 33 | 5-MHz linear probe |
| Lechleitner[ | 2002 | 55 | 25 |
| 69 (23–91) | 29 | 1 | 7 | 18 | 3.75 MHz sector scanner, 7.5 MHz/10.0MHz linear scanner |
| Reissing[ | 2001 | 69 | 61 |
| 62.8 (24–88) | 35 | 2 | 9 | 23 | 5 MHz/ 3.5 Mhz convex scanner |
| Mathis[ | 1999 | 117 | 58 |
| NR | 66 | 6 | 4 | 41 | 3.5 MHz convex probe |
| Lechleitner[ | 1998 | 67 | NR |
| 66 | 18 | 15 | 3 | 31 | 3.75 MHz sector scanner and a 7.5 MHz linear scanne |
| Mathis[ | 1993 | 54 | 54 |
| 63 (21–88) | 41 | 4 | 1 | 8 | 5 MHz sector scanner |
| Kroschel[ | 1991 | 33 | NR |
| 59 (17–85) | 28 | 1 | 3 | 1 | 3.5/ 5 MHz curved / liner probe |
| Mathis[ | 1990 | 33 | NR |
| NR | 27 | 2 | 1 | 3 | 5 MHz sector scanner |
NR, not reported
§, mean(SD)
¶, median(range)
TP = true positive; FP = false positive; FN = false negative; TN = true negative
1†, = yes