Literature DB >> 26058491

Dual-energy X-ray absorptiometry, peripheral quantitative computed tomography, and micro-computed tomography techniques are discordant for bone density and geometry measurements in the guinea pig.

Ivy L Mak1, Jason R DeGuire1, Paula Lavery1, Sherry Agellon1, Hope A Weiler2.   

Abstract

This study aims to examine agreement among bone mineral content (BMC) and density (BMD) estimates obtained using dual-energy X-ray absorptiometry (DXA), peripheral quantitative computed tomography (pQCT), and micro-computed tomography (μCT) against high-resolution μCT and bone ash of the guinea pig femur. Middle-aged (n = 40, 86 weeks) male guinea pigs underwent in vivo followed by ex vivo DXA (Hologic QDR 4500A) scanning for intact and excised femur BMC and areal density. To assess bone architecture and strength, excised femurs were scanned on pQCT (Stratec XCT 2000L) as well as on two μCT scanners (LaTheta LCT-200; Skyscan 1174), followed by three-point bending test. Reproducibility was determined using triplicate scans; and agreement assessed using Bland-Altman plots with reference methods being high-resolution μCT (Skyscan) for BMD and bone ashing for BMC. All techniques showed satisfactory ex vivo precision (CV 0.05-4.3 %). However, bias compared to the reference method was highest (207.5 %) in trabecular bone volume fraction (BV/TV) measured by LaTheta, and unacceptable in most total femur and cortical bone measurements. Volumetric BMD (vBMD) and BV/TV derived by LaTheta and pQCT at the distal metaphysis were biased from the Skyscan by an average of 49.3 and 207.5 %, respectively. Variability of vBMD, BV/TV and cross-sectional area at the diaphysis ranged from -5.5 to 30.8 %. LaTheta best quantified total femur BMC with an upper bias of 3.3 %. The observed differences among imaging techniques can be attributable to inherent dissimilarity in construction design, calibration, segmentation and scanning resolution used. These bone imaging tools are precise but are not comparable, at least when assessing guinea pig bones.

Entities:  

Keywords:  Bone mineral density; Dual-energy X-ray absorptiometry; Guinea pig; Micro-computed tomography; Peripheral quantitative computed tomography

Mesh:

Year:  2015        PMID: 26058491     DOI: 10.1007/s00774-015-0675-1

Source DB:  PubMed          Journal:  J Bone Miner Metab        ISSN: 0914-8779            Impact factor:   2.626


  38 in total

1.  High-resolution three-dimensional micro-computed tomography detects bone loss and changes in trabecular architecture early: comparison with DEXA and bone histomorphometry in a rat model of disuse osteoporosis.

Authors:  Odile Barou; David Valentin; Laurence Vico; Cathrine Tirode; Alain Barbier; Christian Alexandre; Marie-Hélène Lafage-Proust
Journal:  Invest Radiol       Date:  2002-01       Impact factor: 6.016

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Effects of cyclic vs. daily treatment with human parathyroid hormone (1-34) on murine bone structure and cellular activity.

Authors:  Akiko Iida-Klein; Shi Shou Lu; Felicia Cosman; Robert Lindsay; David W Dempster
Journal:  Bone       Date:  2006-10-20       Impact factor: 4.398

Review 4.  Basic biomechanical measurements of bone: a tutorial.

Authors:  C H Turner; D B Burr
Journal:  Bone       Date:  1993 Jul-Aug       Impact factor: 4.398

5.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

6.  Interrelationships between densitometric, geometric, and mechanical properties of rat femora: inferences concerning mechanical regulation of bone modeling.

Authors:  J L Ferretti; R F Capozza; N Mondelo; J R Zanchetta
Journal:  J Bone Miner Res       Date:  1993-11       Impact factor: 6.741

7.  Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT).

Authors:  Corina Schmidt; Matthias Priemel; Thomas Kohler; Axel Weusten; Ralph Müller; Michael Amling; Felix Eckstein
Journal:  J Bone Miner Res       Date:  2003-08       Impact factor: 6.741

8.  Role of subchondral bone in osteoarthritis development: a comparative study of two strains of guinea pigs with and without spontaneously occurring osteoarthritis.

Authors:  Tomoya Muraoka; Hiroshi Hagino; Toru Okano; Makoto Enokida; Ryota Teshima
Journal:  Arthritis Rheum       Date:  2007-10

9.  Enhanced marrow adipogenesis and bone resorption in estrogen-deprived rats treated with the PPARgamma agonist BRL49653 (rosiglitazone).

Authors:  V Sottile; K Seuwen; M Kneissel
Journal:  Calcif Tissue Int       Date:  2004-07-13       Impact factor: 4.333

10.  Precision, accuracy, and reproducibility of dual X-ray absorptiometry measurements in mice in vivo.

Authors:  Akiko Iida-Klein; Shi Shou Lu; Ken Yokoyama; David W Dempster; Jeri W Nieves; Robert Lindsay
Journal:  J Clin Densitom       Date:  2003       Impact factor: 2.963

View more
  1 in total

1.  Dual-energy X-ray absorptiometry underestimates in vivo lumbar spine bone mineral density in overweight rats.

Authors:  Rim Cherif; Laurence Vico; Norbert Laroche; Mohsen Sakly; Nebil Attia; Cedric Lavet
Journal:  J Bone Miner Metab       Date:  2017-02-01       Impact factor: 2.626

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.