Literature DB >> 26040097

Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Marija Škara Kolega, Suzana Kovačević, Samir Čanović, Ana Didović Pavičić, Jadranka Katušić Bašić.   

Abstract

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.

Entities:  

Mesh:

Year:  2015        PMID: 26040097

Source DB:  PubMed          Journal:  Coll Antropol        ISSN: 0350-6134


  5 in total

1.  Comparison of keratometry data using handheld and table-mounted instruments in healthy adults.

Authors:  Hagar Olshaker; Ortal Buhbut; Asaf Achiron; Gad Dotan; Issac Levy; Raimo Tuuminen; Assaf Gershoni; Irit Bahar; Uri Elbaz
Journal:  Int Ophthalmol       Date:  2021-06-09       Impact factor: 2.031

2.  Comparison of ocular parameters of two biometric measurement devices in highly myopic eyes.

Authors:  Xiao-Xiao Guo; Ran You; Shan-Shan Li; Xiu-Fen Yang; Lu Zhao; Fan Zhang; Yan-Ling Wang; Xi Chen
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

3.  Comparison of a new optical biometer and a standard biometer in cataract patients.

Authors:  Pipat Kongsap
Journal:  Eye Vis (Lond)       Date:  2016-10-17

4.  Comparison of optical biometry versus ultrasound biometry in cases with borderline signal-to-noise ratio.

Authors:  Tao Ming Thomas Chia; Minh T Nguyen; Hoon C Jung
Journal:  Clin Ophthalmol       Date:  2018-09-10

5.  Minimum effective volume of local anesthetic in peribulbar block: does it differ with the eyeball axial length?

Authors:  Sanaa M El Fawal; Walid H Nofal; Eman A S Sabek; Wail Ahmed Abdelaal
Journal:  Braz J Anesthesiol       Date:  2021-09-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.