Literature DB >> 2603060

Three-dimensional movements of the whole lumbar spine and lumbosacral joint.

I Yamamoto1, M M Panjabi, T Crisco, T Oxland.   

Abstract

Knowledge of the normal movements of whole lumbar spine and lumbosacral joint is important for evaluating clinical pathologic conditions that may potentially produce unstable situations in these regions. At present there are few studies that report systemic three-dimensional movement analysis of these regions. The purpose of this in vitro study was to quantitatively determine three-dimensional movements of the whole lumbar spine and lumbosacral joint. Ten fresh human cadaveric spine specimens including from L1 to sacrum (six specimens) and ilium (four specimens) were studied. Pure moments of a maximum of 10 N-m were applied incrementally. Parameters of neutral zone, elastic zone, and range of motion for rotations as well as for translations were measured. Neutral zones for flexion-extension, right/left axial torque, and right-left lateral bending were, respectively: 1.6 degrees, 0.9 degrees, and 1.4 degrees (L1-2); 1.0 degrees, 0.8 degrees, and 2.0 degrees (L2-3); 1.4 degrees, 0.7 degrees, and 1.4 degrees (L3-4); 1.8 degrees, 0.4 degrees, and 1.6 degrees (L4-5); 3.0 degrees, 0.4 degrees, and 1.8 degrees (L5-S1). Ranges of motion for flexion, extension, axial torque (one side), and lateral bending (one side) were, respectively: 5.8 degrees, 4.3 degrees, 2.3 degrees, and 4.9 degrees (L1-2); 6.5 degrees, 4.3 degrees, 2.6 degrees, and 7.0 degrees (L2-3); 7.5 degrees, 3.7 degrees, 2.6 degrees, and 5.7 degrees (L3-4); 8.9 degrees, 5.8 degrees, 2.2 degrees, and 5.7 degrees (L4-5); 10.0 degrees, 7.8 degrees, 1.4 degrees, and 5.5 degrees (L5-S1). Neutral zone values were small except for flexion at L5-S1.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2603060     DOI: 10.1097/00007632-198911000-00020

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  95 in total

1.  Biomechanical behaviour in vitro of the spine and lumbosacral junction.

Authors:  X Barthes; B Walter; R Zeller; J F Dubousset
Journal:  Surg Radiol Anat       Date:  1999       Impact factor: 1.246

2.  The sacroiliac part of the iliolumbar ligament.

Authors:  A L Pool-Goudzwaard; G J Kleinrensink; C J Snijders; C Entius; R Stoeckart
Journal:  J Anat       Date:  2001-10       Impact factor: 2.610

3.  Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase.

Authors:  Wolfgang Lehmann; Michael Blauth; Daniel Briem; Ulf Schmidt
Journal:  Eur Spine J       Date:  2003-12-17       Impact factor: 3.134

4.  Spinal muscle forces, internal loads and stability in standing under various postures and loads--application of kinematics-based algorithm.

Authors:  A Shirazi-Adl; M El-Rich; D G Pop; M Parnianpour
Journal:  Eur Spine J       Date:  2004-09-25       Impact factor: 3.134

5.  Intraoperative determination of the load–displacement behavior of scoliotic spinal motion segments: preliminary clinical results.

Authors:  Christoph Reutlinger; Carol Hasler; Klaus Scheffler; Philippe Büchler
Journal:  Eur Spine J       Date:  2012-08       Impact factor: 3.134

6.  Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

Authors:  Ho-Joong Kim; Heoung-Jae Chun; Seong-Hwan Moon; Kyoung-Tak Kang; Hak-Sun Kim; Jin-Oh Park; Eun-Su Moon; Joon-Seok Sohn; Hwan-Mo Lee
Journal:  Med Biol Eng Comput       Date:  2010-05-04       Impact factor: 2.602

7.  Biomechanical changes of the lumbar segment after total disc replacement : charite(r), prodisc(r) and maverick(r) using finite element model study.

Authors:  Ki-Tack Kim; Sang-Hun Lee; Kyung-Soo Suk; Jung-Hee Lee; Bi-O Jeong
Journal:  J Korean Neurosurg Soc       Date:  2010-06-30

8.  Incorporating Six Degree-of-Freedom Intervertebral Joint Stiffness in a Lumbar Spine Musculoskeletal Model-Method and Performance in Flexed Postures.

Authors:  Xiangjie Meng; Alexander G Bruno; Bo Cheng; Wenjun Wang; Mary L Bouxsein; Dennis E Anderson
Journal:  J Biomech Eng       Date:  2015-10       Impact factor: 2.097

9.  Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.

Authors:  Derek P Lindsey; Ali Kiapour; Scott A Yerby; Vijay K Goel
Journal:  Int J Spine Surg       Date:  2015-11-13

10.  Finite element analysis comparing short-segment instrumentation with conventional pedicle screws and the Schanz pedicle screw in lumbar 1 fractures.

Authors:  Fei Zhou; Sheng Yang; Jifeng Liu; Jianmin Lu; Depeng Shang; Chao Chen; Huanhuan Wang; Jinming Ma
Journal:  Neurosurg Rev       Date:  2019-08-02       Impact factor: 3.042

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.