Literature DB >> 26021903

The Effect of Porous Tantalum Cones on Mechanical Alignment and Canal-Fill Ratio in Revision Total Knee Arthroplasty Performed with Uncemented Stems.

Martin Bédard1, Katherine Cabrejo-Jones2, Michèle Angers3, Rémi Pelletier-Roy2, Stéphane Pelet1.   

Abstract

In revision total knee arthroplasty (TKA), the internal diameter of metal cones may limit the ability of the stem to properly fill the medullary canal. We prospectively studied 115 patients who underwent revision TKA with uncemented stems to evaluate the effect of metal cones on mechanical alignment and stem positioning. Correction on the mechanical alignment was well achieved in all patients, regardless of whether a metal cone was used. The proportion of patients achieving restoration of neutral mechanical alignment was similar between groups, as were the mean canal fill ratio (CFR) and the proportion of patients achieving CFR ≥ 85%. The use of porous tantalum cones in revision TKA with uncemented stems is not an obstacle in achieving optimal mechanical alignment and stem positioning.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  canal fill ratio; mechanical alignment; revision total knee arthroplasty; trabecular metal cones; uncemented stems

Mesh:

Substances:

Year:  2015        PMID: 26021903     DOI: 10.1016/j.arth.2015.05.016

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Stem length in revision total knee arthroplasty.

Authors:  Anay Rajendra Patel; Brian Barlow; Amar S Ranawat
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

2.  Revision total knee arthroplasty with porous-coated metaphyseal sleeves provides radiographic ingrowth and stable fixation.

Authors:  Catherine J Fedorka; Antonia F Chen; Michael R Pagnotto; Lawrence S Crossett; Brian A Klatt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-17       Impact factor: 4.342

Review 3.  Are Trabecular Metal Cones a Valid Option to Treat Metaphyseal Bone Defects in Complex Primary and Revision Knee Arthroplasty?

Authors:  Tommaso Bonanzinga; Thorsten Gehrke; Akos Zahar; Stefano Zaffagnini; Maurilio Marcacci; Carl Haasper
Journal:  Joints       Date:  2017-12-14

Review 4.  Metaphyseal cones and sleeves are similar in improving short- and mid-term outcomes in Total Knee Arthroplasty revisions.

Authors:  Umile Giuseppe Longo; Sergio De Salvatore; Giovanni Intermesoli; Francesco Pirato; Ilaria Piergentili; Roland Becker; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-03-02       Impact factor: 4.342

Review 5.  Management of bone loss in revision total knee arthroplasty: therapeutic options and results.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Carlos A Encinas-Ullán
Journal:  EFORT Open Rev       Date:  2021-11-19

6.  Does the use of 3D-printed cones give a chance to postpone the use of megaprostheses in patients with large bone defects in the knee joint?

Authors:  Daniel Kotrych; Sławomir Marcinkowski; Adam Brodecki; Marcin Anuszkiewicz; Jakub Kleszowski; Andrzej Bohatyrewicz; Dawid Ciechanowicz
Journal:  Open Med (Wars)       Date:  2022-07-15

7.  The use of tantalum cones and diaphyseal-engaging stems in tibial component revision: a consecutive series.

Authors:  P Spinello; R A Ruberte Thiele; K Zepeda; N Giori; P F Indelli
Journal:  Knee Surg Relat Res       Date:  2022-03-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.