| Literature DB >> 26018587 |
Christine Marie Zwart1, Miao He, Teresa Wu, Bart M Demaerschalk, Joseph Ross Mitchell, Amy K Hara.
Abstract
BACKGROUND: For health care providers, mobile image viewing increases image accessibility, which could lead to faster interpretation/consultations and improved patient outcomes.Entities:
Keywords: Pilot projects; Radiology; Telemedicine; Teleradiology; mHealth
Year: 2015 PMID: 26018587 PMCID: PMC4463772 DOI: 10.2196/mhealth.4271
Source DB: PubMed Journal: JMIR Mhealth Uhealth ISSN: 2291-5222 Impact factor: 4.773
Figure 1Overview of the ResMD interface and collaboration feature. A single ResMD session running simultaneously: in a desktop web browser (left) and as an application on an Apple iPad (top right). Interactions performed in either view are displayed interactively on both. Collaboration sessions are controlled via a collaboration window (bottom right). The collaboration window allows the “controller” to send invitations (via email), monitor who has joined the session, control the degree of interaction allowed by each user, and limit the display of patient information.
Figure 2Usage counts are shown broken down by device and Internet connection type.
Mobile radiology image viewers compared with conventional desktop viewers: qualitative results by user group.
|
|
| Data points, n | Diagnostic confidence | Ease of use | Fraction of cases with technical issues, n (%) |
|
|
|
|
|
|
|
|
| PACS | 91 | 3.8 | 3.6 | 7/91 (7.7) |
|
| ENTERPRISE | 215 | 3.4 | 2.9 | 56/215 (26.0) |
|
| MOBILE | 259 | 3.7 | 3.6 | 19/259 (7.3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PACS | 89 | 3.8 | 3.6 | 7/89 (7.9) |
|
| ENTERPRISE | 2 | 3.0 | 3.0 | 0/2 (0.0) |
|
| MOBILE | 71 | 3.4 | 3.5 | 8/71 (11.3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PACS | 0 | N/A | N/A | N/A |
|
| ENTERPRISE | 29 | 3.6 | 3.4 | 6/29 (20.7) |
|
| MOBILE | 41 | 3.9 | 3.8 | 3/41 (7.3) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PACS | 0 | N/A | N/A | N/A |
|
| ENTERPRISE | 43 | 3.0 | 2.6 | 27/43 (62.8) |
|
| MOBILE | 27 | 3.6 | 3.8 | 0/27 (0.0) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PACS | 2 | 3.0 | 2.0 | 0/2 (0.0) |
|
| ENTERPRISE | 91 | 3.2 | 2.5 | 14/91 (15.4) |
|
| MOBILE | 120 | 3.6 | 3.5 | 8/120 (6.7) |
Time to first image in minutes by type of image viewer.
| Time/location | PACS | ENTERPRISE | MOBILE |
| All data points | 12.5 | 4.5 | 2.4 |
| Inside hospital | 11.4 | 3.9a | 2.7b |
| Outside hospital | 12.7 | 7.9a | 2.0b |
| During work hours (weekdays 7 am to 6 pm) | 9.6 | 4.3a | 2.2b |
| After work hours | 12.9 | 5.3a | 2.5b |
a P=.01 vs PACS
b P<.01 vs PACS and ENTERPRISE custom viewer