Literature DB >> 2601432

Automatisation of the single-breath nitrogen washout test.

M F Melo, A Giannella Neto.   

Abstract

The paper presents a computer-based system for performance and analysis of the single-breath nitrogen washout test (Sb-N2 test). A pneumotachometer and a rapid gas analyser are used for volume flow rate and nitrogen fraction measurements. The data are acquired and analysed by a PDP-11/34 computer. Several sources of measurement errors are considered. An algorithm is proposed to reduce errors in flow measurements due to viscosity variation in respired air. The algorithm for closing volume (CV) detection and calculation of other Sb-N2 parameters is developed from 50 tracings of 18 subjects. The CV is obtained by an iterative linear fitting of the later half of the Sb-N2 curve. Comparisons between computer and hand measurements of three trained readers show good correlations (r = 0.87, 0.93, 0.91). The variability of computer CV measurements was comparable with that of the hand reader with the lowest variance. The coefficient of variation of residual volume and slope of alveolar plateau measurements are apparently reduced. The results demonstrate the adequacy and convenience of using the computer to analyse the Sb-N2 test and indicate that the automation allows for reduction of experimental errors and of test parameter variabilities.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2601432     DOI: 10.1007/bf02446222

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  30 in total

1.  Pneumotachograph for flow and volume measurement in normal and dense atmospheres.

Authors:  R Gelfand; C J Lambertsen; R E Peterson; A Slater
Journal:  J Appl Physiol       Date:  1976-07       Impact factor: 3.531

2.  Aspects of on-line digital integration of pulmonary gas transfer.

Authors:  T E Bernard
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-08

3.  Computer determined closing volumes.

Authors:  J L Hankinson
Journal:  Comput Biomed Res       Date:  1977-06

4.  Computer analysis of the single-breath nitrogen washout curve.

Authors:  N Craven; G Sidwall; P West; D S McCarthy; R M Cherniack
Journal:  Am Rev Respir Dis       Date:  1976-04

5.  Computer simulation of mammalian gas-exchange.

Authors:  K S Kapitan; S C Hempleman
Journal:  Comput Biol Med       Date:  1986       Impact factor: 4.589

6.  Heated Fleisch pneumotachometer: a calibration procedure.

Authors:  S Z Turney; W Blumenfeld
Journal:  J Appl Physiol       Date:  1973-01       Impact factor: 3.531

7.  Accurate measurement of N2 volumes during N2 washout requires dynamic adjustment of delay time.

Authors:  J X Brunner; G Wolff; G Cumming; H Langenstein
Journal:  J Appl Physiol (1985)       Date:  1985-09

8.  Effect of O2, N2, and CO2 composition on nonlinearity of Fleisch pneumotachograph characteristics.

Authors:  M P Yeh; T D Adams; R M Gardner; F G Yanowitz
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1984-05

9.  Metabolic gas effect on phase III slopes of single-breath nitrogen tests.

Authors:  Y Cormier; J Bélanger
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-09

10.  Computer program for the production of O2-CO2 diagrams.

Authors:  G R Kelman
Journal:  Respir Physiol       Date:  1968-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.