Literature DB >> 6427156

Effect of O2, N2, and CO2 composition on nonlinearity of Fleisch pneumotachograph characteristics.

M P Yeh, T D Adams, R M Gardner, F G Yanowitz.   

Abstract

Although the Fleisch pneumotachograph has many advantages, its flow-conductance characteristics are nonlinear and sensitive to changes in gas composition. The purpose of this study was to assess the effect of different O2, N2, and CO2 compositions on the nonlinearity of the Fleisch pneumotachograph flow-conductance characteristics, by use of a recently developed computerized calibration method. Hospital-grade O2 was mixed with room air to obtain seven gas mixtures (containing O2 percentages of 20.9, 28.3, 38.7, 52.8, 66.7, 78.7, and 99.6%). Within the accuracy of the applied method, the measured flow-conductance curves of the pneumotachograph had the same shape. Relative flow resistance of gas mixtures to room air was directly proportional to their O2 composition. Two O2-N2-CO2 mixtures were also tested. Their relative flow resistance compared with room air was proportional to the viscosity ratios. We concluded that the change in O2, N2, and CO2 composition does not affect the nonlinearity of the Fleisch pneumotachograph flow-conductance characteristics. However, the relative flow resistance compared with room air does change in a predictable way.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6427156     DOI: 10.1152/jappl.1984.56.5.1423

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  6 in total

1.  Automatisation of the single-breath nitrogen washout test.

Authors:  M F Melo; A Giannella Neto
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

2.  Comparison of pneumotachography and anemometery for flow measurement during mechanical ventilation with volatile anesthetics.

Authors:  Jarred R Mondoñedo; Jacob Herrmann; John S McNeil; David W Kaczka
Journal:  J Clin Monit Comput       Date:  2016-11-14       Impact factor: 2.502

3.  The need for specificity in quantifying neurocirculatory vs. respiratory effects of eucapnic hypoxia and transient hyperoxia.

Authors:  Bharati Prasad; Barbara J Morgan; Ahana Gupta; David F Pegelow; Mihaela Teodorescu; John M Dopp; Jerome A Dempsey
Journal:  J Physiol       Date:  2020-08-25       Impact factor: 5.182

4.  Actual performance of mechanical ventilators in ICU: a multicentric quality control study.

Authors:  Leonardo Govoni; Raffaele L Dellaca'; Oscar Peñuelas; Giacomo Bellani; Antonio Artigas; Miquel Ferrer; Daniel Navajas; Antonio Pedotti; Ramon Farré
Journal:  Med Devices (Auckl)       Date:  2012-12-20

5.  Nonlinear Flow Sensor Calibration with an Accurate Syringe.

Authors:  Paolo Jose Cesare Biselli; Raquel Siqueira Nóbrega; Francisco Garcia Soriano
Journal:  Sensors (Basel)       Date:  2018-07-05       Impact factor: 3.576

6.  Inspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation.

Authors:  Jordan A Guenette; Roberto C Chin; Julia M Cory; Katherine A Webb; Denis E O'Donnell
Journal:  Pulm Med       Date:  2013-02-07