Literature DB >> 26003146

Echocardiographic evaluation of prosthetic heart valves.

Haïfa Mahjoub1, Philippe Pibarot, Jean-Gaston Dumesnil.   

Abstract

The specific flow pattern and imaging features of prosthetic heart valves poses major challenges for the Doppler echocardiographic assessment of prosthetic valve structure and function. A comprehensive approach that integrates several semi-quantitative and quantitative parameters obtained from multiple views is key to appropriately detect and quantitate prosthetic valve dysfunction and complications. In patients with prosthetic valves, and particularly in those with mitral prostheses, transesophageal echocardiography is often required to confirm and/or complement information obtained by transthoracic echocardiography. Three-dimensional echocardiography may provide incremental information for the identification of the underlying etiology of prosthetic valve stenosis or regurgitation. Transcatheter aortic valve implantation has rapidly expanded in the past 10 years and paravalvular regurgitation is frequent following this procedure. Given that paravalvular regurgitant jets are often multiple, irregular, and eccentric, the grading of this type of regurgitation is particularly challenging and requires an integrative multiwindow, multiplane, multiparametric approach.

Entities:  

Mesh:

Year:  2015        PMID: 26003146     DOI: 10.1007/s11886-015-0602-z

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  27 in total

Review 1.  Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve.

Authors:  Sonia Jain; Joseph F Malouf
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature.

Authors:  Ganesh Athappan; Eshan Patvardhan; E Murat Tuzcu; Lars Georg Svensson; Pedro A Lemos; Chiara Fraccaro; Giuseppe Tarantini; Jan-Malte Sinning; Georg Nickenig; Davide Capodanno; Corrado Tamburino; Azeem Latib; Antonio Colombo; Samir R Kapadia
Journal:  J Am Coll Cardiol       Date:  2013-04-16       Impact factor: 24.094

3.  Accuracy of Doppler-echocardiographic parameters for the detection of aortic bileaflet mechanical prosthetic valve dysfunction.

Authors:  Othman Smadi; Julio Garcia; Philippe Pibarot; Emmanuel Gaillard; Ibrahim Hassan; Lyes Kadem
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-05-15       Impact factor: 6.875

4.  ApoB/ApoA-I ratio is associated with increased risk of bioprosthetic valve degeneration.

Authors:  Haïfa Mahjoub; Patrick Mathieu; Mario Sénéchal; Eric Larose; Jean Dumesnil; Jean-Pierre Després; Philippe Pibarot
Journal:  J Am Coll Cardiol       Date:  2013-02-19       Impact factor: 24.094

Review 5.  A practical guide to multimodality imaging of transcatheter aortic valve replacement.

Authors:  Gerald S Bloomfield; Linda D Gillam; Rebecca T Hahn; Samir Kapadia; Jonathon Leipsic; Stamatios Lerakis; Murat Tuzcu; Pamela S Douglas
Journal:  JACC Cardiovasc Imaging       Date:  2012-04

6.  Flow acceleration time and ratio of acceleration time to ejection time for prosthetic aortic valve function.

Authors:  Sagit Ben Zekry; Robert M Saad; Mehmet Ozkan; Maie S Al Shahid; Mauro Pepi; Manuela Muratori; Jiaqiong Xu; Stephen H Little; William A Zoghbi
Journal:  JACC Cardiovasc Imaging       Date:  2011-11

7.  Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography.

Authors:  A Vitarelli; Y Conde; E Cimino; T Leone; I D'Angeli; S D'Orazio; S Stellato
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

8.  Localized transvalvular pressure gradients in mitral bileaflet mechanical heart valves and impact on gradient overestimation by Doppler.

Authors:  Morgane Evin; Philippe Pibarot; Carine Guivier-Curien; David Tanné; Lyes Kadem; Regis Rieu
Journal:  J Am Soc Echocardiogr       Date:  2013-04-20       Impact factor: 5.251

9.  Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves.

Authors:  M E Alton; T J Pasierski; D A Orsinelli; G M Eaton; A C Pearson
Journal:  J Am Coll Cardiol       Date:  1992-12       Impact factor: 24.094

10.  Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival.

Authors:  Zeineb Hachicha; Jean G Dumesnil; Peter Bogaty; Philippe Pibarot
Journal:  Circulation       Date:  2007-05-28       Impact factor: 29.690

View more
  2 in total

1.  Onset of new diastolic murmur as a sign of bioprosthetic valve dysfunction: A case report.

Authors:  Momoko Habu; Tatsuya Kawasaki; Michiyo Yamano; Tadaaki Kamitani
Journal:  J Cardiol Cases       Date:  2019-01-10

Review 2.  Echocardiography in Pregnancy: Part 2.

Authors:  Meena Narayanan; Uri Elkayam; Tasneem Z Naqvi
Journal:  Curr Cardiol Rep       Date:  2016-09       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.