Literature DB >> 25998382

MRI measurement of blood-brain barrier transport with a rapid acquisition refocused echo (RARE) method.

Jeffrey H Walton1, Kit Fai Ng2, Steven E Anderson3, John C Rutledge2.   

Abstract

Dynamic Contrast Enhanced (DCE) MRI is increasingly being used to assess changes in capillary permeability. Most quantitative techniques used to measure capillary permeability are based on the Fick equation that requires measurement of signal reflecting both plasma and tissue concentrations of the solute being tested. To date, most Magnetic Resonance Imaging (MRI) methods for acquiring appropriate data quickly rely on gradient recalled echo (GRE) type acquisitions, which work well in clinical low field settings. However, acquiring this type of data on high field small animal preclinical MRIs is problematic due to geometrical distortions from susceptibility mismatch. This problem can be exacerbated when using small animal models to measure blood brain barrier (BBB) permeability, where precise sampling from the superior sagittal sinus (SSS) is commonly used to determine the plasma concentration of the contrast agent. Here we present results demonstrating that a standard saturation recovery rapid acquisition refocused echo (RARE) method is capable of acquiring T1 maps with good spatial and temporal resolution for Patlak analysis (Patlak, 1983) to assess changes in BBB Gd-DTPA permeability following middle cerebral artery occlusion with reperfusion in the rat. This method limits known problems with magnetic susceptibility mismatch and may thus allow greater accuracy in BBB permeability measurement in small animals.
Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  DCE-MRI; RARE; Rapid acquisition refocused echo; Rat brain capillary transport

Mesh:

Year:  2015        PMID: 25998382      PMCID: PMC4552450          DOI: 10.1016/j.bbrc.2015.05.034

Source DB:  PubMed          Journal:  Biochem Biophys Res Commun        ISSN: 0006-291X            Impact factor:   3.575


  18 in total

1.  Adiabatic RARE imaging.

Authors:  Robin A de Graaf; Douglas L Rothman; Kevin L Behar
Journal:  NMR Biomed       Date:  2003-02       Impact factor: 4.044

2.  Angioarchitectural changes in subacute cerebral venous thrombosis. A synchrotron-based micro- and nano-CT study.

Authors:  Erwin Stolz; Mesut Yeniguen; Melanie Kreisel; Marian Kampschulte; Simone Doenges; Daniel Sedding; Erik L Ritman; Tibo Gerriets; Alexander C Langheinrich
Journal:  Neuroimage       Date:  2010-10-23       Impact factor: 6.556

3.  Quantitative measurement of blood-brain barrier permeability in human using dynamic contrast-enhanced MRI with fast T1 mapping.

Authors:  Saeid Taheri; Charles Gasparovic; Nadim Jon Shah; Gary A Rosenberg
Journal:  Magn Reson Med       Date:  2010-12-13       Impact factor: 4.668

4.  The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: a comparison of snapshot imaging techniques.

Authors:  S M Grieve; A M Blamire; P Styles
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

5.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data.

Authors:  C S Patlak; R G Blasberg; J D Fenstermacher
Journal:  J Cereb Blood Flow Metab       Date:  1983-03       Impact factor: 6.200

6.  Intravenous HOE-642 reduces brain edema and Na uptake in the rat permanent middle cerebral artery occlusion model of stroke: evidence for participation of the blood-brain barrier Na/H exchanger.

Authors:  Martha E O'Donnell; Yi-Je Chen; Tina I Lam; Kelleen C Taylor; Jeffrey H Walton; Steven E Anderson
Journal:  J Cereb Blood Flow Metab       Date:  2012-11-14       Impact factor: 6.200

7.  In vivo measurement of transverse relaxation time in the mouse brain at 17.6 T.

Authors:  Firat Kara; Fu Chen; Itamar Ronen; Huub J M de Groot; Jörg Matysik; A Alia
Journal:  Magn Reson Med       Date:  2012-11-14       Impact factor: 4.668

8.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Patlak plots of Gd-DTPA MRI data yield blood-brain transfer constants concordant with those of 14C-sucrose in areas of blood-brain opening.

Authors:  James R Ewing; Robert A Knight; Tavarekere N Nagaraja; John S Yee; Vijaya Nagesh; Polly A Whitton; Lian Li; Joseph D Fenstermacher
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

10.  MRI measurement of blood-brain barrier permeability following spontaneous reperfusion in the starch microsphere model of ischemia.

Authors:  Neil G Harris; Victoria Gauden; Paul A Fraser; Stephen R Williams; Geoff J M Parker
Journal:  Magn Reson Imaging       Date:  2002-04       Impact factor: 2.546

View more
  4 in total

1.  Triglyceride-rich lipoprotein lipolysis products increase blood-brain barrier transfer coefficient and induce astrocyte lipid droplets and cell stress.

Authors:  Linda L Lee; Hnin H Aung; Dennis W Wilson; Steven E Anderson; John C Rutledge; Jennifer M Rutkowsky
Journal:  Am J Physiol Cell Physiol       Date:  2017-01-11       Impact factor: 4.249

Review 2.  Pathophysiology of the cochlear intrastrial fluid-blood barrier (review).

Authors:  Xiaorui Shi
Journal:  Hear Res       Date:  2016-01-20       Impact factor: 3.208

3.  Characterizing blood-brain barrier perturbations after exposure to human triglyceride-rich lipoprotein lipolysis products using MRI in a rat model.

Authors:  Kit Fai Ng; Steve Anderson; Patrice Mayo; Hnin Hnin Aung; Jeffrey H Walton; John C Rutledge
Journal:  Magn Reson Med       Date:  2015-10-20       Impact factor: 4.668

4.  The Structure and the Function of the Cochlear Intra-Strial Fluid-Blood Barrier.

Authors:  Xiaohan Wang
Journal:  Otolaryngol (Sunnyvale)       Date:  2017-05-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.