Literature DB >> 12577295

Adiabatic RARE imaging.

Robin A de Graaf1, Douglas L Rothman, Kevin L Behar.   

Abstract

The practical implementation of ultra-fast spin-echo, or RARE imaging with adiabatic RF pulses and surface coil transmission at 7 T is described. Despite the large RF inhomogeneities, the adiabatic character of the 180 degrees BIR-4 refocusing pulses ensures optimal sensitivity and minimal image artifacts. An internal 'phase-cycle' is used to remove spurious unwanted coherences. The short T(2) relaxation times in rat brain at 7 T demand a centric, rather than a linear coverage of k-space in order to avoid excessive signal loss. T(2) relaxation during k-space coverage also leads to image blurring, which can be counteracted by interleaved k-space sampling. The coverage of k-space in four acquisitions provides high-quality anatomical images comparable to conventional spin-echo images. A two-scan RARE implementation provides sufficient spatial and temporal resolution for most applications. Quantitative mapping of T(1) relaxation and cerebral blood flow changes during forepaw stimulation in the rat are demonstrated. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12577295     DOI: 10.1002/nbm.811

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  5 in total

1.  Regional glucose metabolism and glutamatergic neurotransmission in rat brain in vivo.

Authors:  Robin A de Graaf; Graeme F Mason; Anant B Patel; Douglas L Rothman; Kevin L Behar
Journal:  Proc Natl Acad Sci U S A       Date:  2004-08-13       Impact factor: 11.205

2.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

3.  MRI measurement of blood-brain barrier transport with a rapid acquisition refocused echo (RARE) method.

Authors:  Jeffrey H Walton; Kit Fai Ng; Steven E Anderson; John C Rutledge
Journal:  Biochem Biophys Res Commun       Date:  2015-05-19       Impact factor: 3.575

4.  Ultrashort echo time (UTE) imaging of receptor targeted magnetic iron oxide nanoparticles in mouse tumor models.

Authors:  Liya Wang; Xiaodong Zhong; Weiping Qian; Jing Huang; Zehong Cao; Qiqi Yu; Malgorzata Lipowska; Run Lin; Andrew Wang; Lily Yang; Hui Mao
Journal:  J Magn Reson Imaging       Date:  2014-11       Impact factor: 4.813

5.  Performance of external and internal coil configurations for prostate investigations at 7 T.

Authors:  Gregory J Metzger; Pierre-Francois van de Moortele; Can Akgun; Carl J Snyder; Steen Moeller; John Strupp; Peter Andersen; Devashish Shrivastava; Tommy Vaughan; Kamil Ugurbil; Gregor Adriany
Journal:  Magn Reson Med       Date:  2010-08-25       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.