Literature DB >> 25993705

Oscillometric Blood Pressure Estimation: Past, Present, and Future.

Mohamad Forouzanfar, Hilmi R Dajani, Voicu Z Groza, Miodrag Bolic, Sreeraman Rajan, Izmail Batkin.   

Abstract

The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at home. Oscillometry is one of the most common measurement methods used in automated BP monitors. A review of the literature shows that a large variety of oscillometric algorithms have been developed for accurate estimation of BP but these algorithms are scattered in many different publications or patents. Moreover, considering that oscillometric devices dominate the home BP monitoring market, little effort has been made to survey the underlying algorithms that are used to estimate BP. In this review, a comprehensive survey of the existing oscillometric BP estimation algorithms is presented. The survey covers a broad spectrum of algorithms including the conventional maximum amplitude and derivative oscillometry as well as the recently proposed learning algorithms, model-based algorithms, and algorithms that are based on analysis of pulse morphology and pulse transit time. The aim is to classify the diverse underlying algorithms, describe each algorithm briefly, and discuss their advantages and disadvantages. This paper will also review the artifact removal techniques in oscillometry and the current standards for the automated BP monitors.

Entities:  

Mesh:

Year:  2015        PMID: 25993705     DOI: 10.1109/RBME.2015.2434215

Source DB:  PubMed          Journal:  IEEE Rev Biomed Eng        ISSN: 1937-3333


  22 in total

1.  History and Justification of a National Blood Pressure Measurement Validated Device Listing.

Authors:  Jordana B Cohen; Raj S Padwal; Michael Gutkin; Beverly B Green; Michael J Bloch; F Wilford Germino; Domenic A Sica; Anthony J Viera; Benjamin M Bluml; William B White; Sandra J Taler; Steven Yarows; Daichi Shimbo; Raymond R Townsend
Journal:  Hypertension       Date:  2019-02       Impact factor: 10.190

2.  Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices.

Authors:  Pavol Sajgalik; Vaclav Kremen; Vratislav Fabian; Simon Maltais; John M Stulak; Sudhir S Kushwaha; Lyle D Joyce; John A Schirger; Bruce D Johnson
Journal:  ASAIO J       Date:  2019-02       Impact factor: 2.872

Review 3.  Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure.

Authors:  James E Sharman; Isabella Tan; George S Stergiou; Carolina Lombardi; Francesca Saladini; Mark Butlin; Raj Padwal; Kei Asayama; Alberto Avolio; Tammy M Brady; Alan Murray; Gianfranco Parati
Journal:  J Hum Hypertens       Date:  2022-05-30       Impact factor: 3.012

Review 4.  The Story of the Silent Killer : A History of Hypertension: Its Discovery, Diagnosis, Treatment, and Debates.

Authors:  Jonathan P Kalehoff; Suzanne Oparil
Journal:  Curr Hypertens Rep       Date:  2020-08-27       Impact factor: 5.369

5.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

Authors:  In Cheol Jeong; Joseph Finkelstein
Journal:  J Med Syst       Date:  2016-01-20       Impact factor: 4.460

6.  A convenient method to verify the accuracy of oscillometric blood pressure monitors by the auscultatory method: A smartphone-based app.

Authors:  Zhi Zhang; Weichun Xi; Bingjiang Wang; Guang Chu; Fang Wang
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-12-20       Impact factor: 3.738

7.  Assessing the accuracy of the OMRON HEM-907XL oscillometric blood pressure measurement device in patients with nondialytic chronic kidney disease.

Authors:  Jordana B Cohen; Tiffany C Wong; Bruce S Alpert; Raymond R Townsend
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-01-12       Impact factor: 3.738

8.  The ongoing saga of poor blood pressure measurement: Past, present, and future perspectives.

Authors:  Jennifer Ringrose; Raj Padwal
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-05-02       Impact factor: 3.738

9.  The elegance of simplicity.

Authors:  Jennifer Ringrose; Sangita Sridar
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-06-07       Impact factor: 3.738

10.  Effect of cuff positioning on the accuracy of blood pressure measurement with automated electronic blood pressure monitors.

Authors:  Ya Li; Fang Li; Yi Li; Xiaoran Cui; Jing Li; Hua Zhi; Weidong Wang; Yanyan Sun; Wei Cui
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-06-09       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.