Literature DB >> 25987590

Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience.

Geoffrey P Colby1, Li-Mei Lin1, Justin M Caplan1, Bowen Jiang1, Barbara Michniewicz1, Judy Huang1, Rafael J Tamargo1, Alexander L Coon1.   

Abstract

BACKGROUND: Flow diversion is an important tool for treatment of cerebral aneurysms, particularly large and giant aneurysms. The Surpass flow diverter is a new system under evaluation in the USA.
OBJECTIVE: To report our initial experience of 20 cases with the Surpass flow diverter to demonstrate its basic properties, the required triaxial delivery platform, and the methodologies used to deploy it during treatment of large internal carotid artery (ICA) aneurysms
METHODS: Twenty patients with ICA aneurysms ≥10 mm with ≥4 mm neck treated as part of the Surpass IntraCranial Aneurysm Embolization System Pivotal Trial (the SCENT trial; Stryker) were included. Details of patient demographics, aneurysm characteristics, and technical procedures were collected.
RESULTS: Twenty patients (mean age 63.3±1.3 years; range 51-72) with 20 unruptured aneurysms (mean size 13.4±0.9 mm; range 10-21 mm) were treated. For proximal access, 60% of cases had aortic arch ≥grade II, 55% had significant cervical ICA tortuosity, and 60% had cavernous ICA ≥grade II. The Surpass device was implanted in 19/20 (95%) cases. Of 19 cases, a single device was used in 18 cases (95%) and 2 devices in only 1 case (5%). Balloon angioplasty was performed in 8/19 cases (42%). Complete aneurysm neck coverage and adequate vessel wall apposition was obtained in all 19 cases.
CONCLUSIONS: Surpass is a next-generation flow diverter with unique device-specific and delivery-specific features compared with clinically available endoluminal flow diverters. Our initial experience demonstrates a favorable technical profile in treatment of large and giant ICA aneurysms. TRIAL REGISTRATION NUMBER: NCT01716117. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Aneurysm; Catheter; Device; Flow Diverter; Stent

Mesh:

Year:  2015        PMID: 25987590     DOI: 10.1136/neurintsurg-2015-011769

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  12 in total

1.  Flow Diversion for Intracranial Aneurysm Management: A New Standard of Care.

Authors:  Fawaz Al-Mufti; Krishna Amuluru; Chirag D Gandhi; Charles J Prestigiacomo
Journal:  Neurotherapeutics       Date:  2016-07       Impact factor: 7.620

Review 2.  On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management.

Authors:  A A Dmytriw; K Phan; J M Moore; V M Pereira; T Krings; A J Thomas
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-20       Impact factor: 3.825

3.  Usefulness of Cone Beam Intra-Arterial CTA for Evaluation of Flow Diverters: A Practical Approach for Daily Use.

Authors:  Dennys Reyes; Victor Becerra; Indiana Alcala; Italo Linfante; Guilherme Dabus
Journal:  Interv Neurol       Date:  2018-07-18

4.  Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent: mid-term results in 35 patients with 41 intracranial aneurysms.

Authors:  Ricardo Morais; Benjamin Mine; Pierre Julien Bruyère; Gilles Naeije; Boris Lubicz
Journal:  Neuroradiology       Date:  2017-02-24       Impact factor: 2.804

5.  The Exchange-Free Technique: A Novel Technique for Enhancing Surpass Flow Diverter Placement.

Authors:  Osman Ocal; Anıl Arat
Journal:  Asian J Neurosurg       Date:  2020-08-28

Review 6.  Cerebral aneurysm treatment: modern neurovascular techniques.

Authors:  Bowen Jiang; Michelle Paff; Geoffrey P Colby; Alexander L Coon; Li-Mei Lin
Journal:  Stroke Vasc Neurol       Date:  2016-10-25

Review 7.  Development of New Endovascular Devices for Aneurysm Treatment.

Authors:  Zhen Yu Jia; Hai Bin Shi; Shigeru Miyachi; Sun Moon Hwang; Jae Jon Sheen; Yun Sun Song; Joong Goo Kim; Deok Hee Lee; Dae Chul Suh
Journal:  J Stroke       Date:  2018-01-31       Impact factor: 6.967

8.  The Evolution of Flow-Diverting Stents for Cerebral Aneurysms; Historical Review, Modern Application, Complications, and Future Direction.

Authors:  Dong-Seong Shin; Christopher P Carroll; Mohammed Elghareeb; Brian L Hoh; Bum-Tae Kim
Journal:  J Korean Neurosurg Soc       Date:  2020-02-27

9.  47 Consecutive Cases of Pipeline Flex Flow Diversion Utilizing a Novel Large-Bore Intracranial Intermediate Catheter: Nuances and Institutional Experience with the Syphontrak.

Authors:  Li-Mei Lin; Bowen Jiang; Matthew T Bender; Erick M Westbroek; Jessica K Campos; Rafael J Tamargo; Judy Huang; Alexander L Coon; Geoffrey P Colby
Journal:  Interv Neurol       Date:  2018-02-06

Review 10.  Multimodal management of giant cerebral aneurysms: review of literature and case presentation.

Authors:  Jessica K Campos; Benjamin Z Ball; Barry Cheaney Ii; Alexander J Sweidan; Bima J Hasjim; Frank P K Hsu; Alice S Wang; Li-Mei Lin
Journal:  Stroke Vasc Neurol       Date:  2020-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.